| Additional features |
| Application category | AC-3; AC-3e; AC-1; AC-4 |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 12 A (at |
| Control circuit type | DC Standard |
| [Uc] control circuit voltage | 24 V DC |
| Motor power (kW) | 3 kW at 220 - 230 V AC 50/60 Hz AC-3; 5.5 kW at 380 - 415 V AC 50/60 Hz AC-3; 5.5 kW at 440 V AC 50/60 Hz AC-3; 4 kW at 690 V AC 50/60 Hz AC-3; 3 kW at 220 - 230 V AC 50/60 Hz AC-3e; 5.5 kW at 380 - 415 V AC 50/60 Hz AC-3e; 5.5 kW at 440 V AC 50/60 Hz AC-3e; 4 kW at 690 V AC 50/60 Hz AC-3e; 3 kW at 220 - 230 V AC 50/60 Hz AC-4; 5.5 kW at 380 - 415 V AC 50/60 Hz AC-4; 5.5 kW at 440 V AC 50/60 Hz AC-4; 4 kW at 690 V AC 50/60 Hz AC-4 |
| Configuration of auxiliary contacts | 1 S |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 16 A (at 60 °C) for circuit; 10 A (at 50 °C) for signal circuit |
| [Irms] Rated making capacity | 144 A AC for circuit conforming to IEC 60947; 110 A AC for signal circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 440 V corresponds to IEC 60947; 80 A at 500 V corresponds to IEC 60947; 70 A at 660 - 690 V corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 115 A at 50 °C - 1 s for circuit; 105 A at 50 °C - 5 s for circuit; 100 A at 50 °C - 10 s for circuit; 75 A at 50 °C - 30 s for circuit; 55 A at 50 °C - 1 min for circuit; 50 A at 50 °C - 3 min for circuit; 25 A at 50 °C - >= 15 min for circuit; 80 A - 1 s for signal circuit; 90 A - 500 ms for signal circuit; 110 A - 100 ms for signal circuit |
| Associated fuse | 25 A gG at |
| Average impedance | 3 MOhm - Ith 16 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 600 V complies with UL 508; Circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-5-1; Signal circuit: 600 V complies with UL 508; Circuit: 600 V complies with CSA C22.2 No. 14; Signal circuit: 600 V complies with CSA C22.2 No. 14 |
| Insulation resistance | > 10 MΩ for signal circuits |
| Absorption power in W | 3 W (at 20 °C) |
| Holding power consumption in W | 3 W at 20 °C |
| Heat emission | 1,3 W |
| Control circuit voltage limits | Operation: 0.8 - 1.15 Uc (at = 0.10 Uc (at |
| Connections - terminals | Spring terminals 1 cable(s) 0.75…1.5 mm² solid; spring terminals 1 cable(s) 0.75…1.5 mm² fine-stranded without cable end; spring terminals 2 cable(s) 0.75…1.5 mm² fine-stranded without cable end |
| Max. operating rate | 3600 cyc/h |
| Coil technology | With integrated suppression unit |
| Type of auxiliary contacts | Type instantaneous 1 S |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Mounting bracket | Rail; Plate |
| Operating time | 30 - 40 ms coil excitation and NO closing; 10 ms coil de-energisation and NO opening |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 10 Mcycles |
| Electrical lifetime | 1.3 Mcycles 12 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Product weight | 0,225 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys |
| Product or component type | Contactor |
| Device short name | LP1K |
| Application of contactor | Resistive load; motor control |
| Mounting |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No. 60947-4-1; CSA C22.2 No. 60947-5-1; GB/T 14048.4 |
| Product certifications | CB certification; CCC; UL; CSA; EAC; CE; UKCA |
| Degree of protection (IP) | IP2x |
| Operating ambient temperature | -25…50 °C |
| Ambient temperature during storage | -50…80 °C |
| Operating altitude | 2,000 m without derating |
| Flame retardancy | V1 corresponds to UL 94; Requirement 2 corresponds to NF F 16-101; Requirement 2 corresponds to NF F 16-102 |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 4,900 cm |
| VPE 1 width | 6,200 cm |
| VPE 1 length | 6,800 cm |
| Packaging weight (Lbs) | 228,000 g |
| VPE 2 type | S02 |
| VPE 2 quantity | 40 |
| VPE 2 height | 15,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 9,495 kg |
TeSys LP1K power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact, rated operating power at AC-3, 400 V 5.5 kW, rated operating current Ie at AC-3, 400 V 12 A, coil 24 V DC. Dimensions (WxHxD) 45x58x57 mm, weight 0.225 kg. Category AC-3, AC-4, AC-1. Integrated bidirectional amplitude limiter diode. Simple machine control in industry, infrastructure and building applications. Easy-to-use interface for electronic devices (PLC). Certifications according to CSA, UL. Product standards in accordance with.