| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | DC standard |
| [Uc] control circuit voltage | 24 V DC |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in W | 3 W (at 20 °C) |
| Hold-in power consumption in W | 3 W at 20 °C |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.10 Uc (at |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Auxiliary contacts type | type instantaneous 1 NC |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting support | Rail; Plate |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 30...40 ms coil energisation and NO closing; 10 ms coil de-energisation and NO opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.225 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LP1K |
| Contactor application | Resistive load; Motor control |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.600 cm |
| Package 1 Width | 4.800 cm |
| Package 1 Length | 6.200 cm |
| Package 1 Weight | 220.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.320 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 640 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 159.035 kg |
The LP1K0901BD contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads in industrial, infrastructure, and building applications. It has a rated operational current of 9 A at 400 V AC in usage category AC-3 and is designed for motor power up to 4 kW, with the exact power depending on the operating voltage. The coil is designed for a control circuit voltage of 24 V DC, enabling integration into existing control systems with DC networks. The device is suitable for use in categories AC-1, AC-3, AC-3e, and AC-4, making it applicable for both continuous loads and drives with high inrush and braking currents.
Applications
This contactor is designed for controlling electric drives in machine building, material handling, building technology, and other industrial environments. It is particularly suitable for applications requiring simple and reliable machine control. The interface is designed for use with electronic control devices such as PLCs (Programmable Logic Controllers), enabling flexible integration into automated systems.
Functions and Equipment in Detail
The device features a contact configuration of 3 normally closed contacts in the main current circuit, supplemented by an additional auxiliary contact in normally open function. These auxiliary contacts are used for signal transmission in control and monitoring systems. The auxiliary contacts are non-delayed, enabling direct and rapid response to switching operations. The maximum operational rate is 3600 switching operations per hour, highlighting high dynamic load capacity.
Technology Explained Simply
The contactor coil is operated at 24 V DC and consumes 3 W of pickup power and 3 W of holding power at 20 °C. The heat dissipation is 1.3 W, indicating efficient thermal design. The rated impulse voltage withstand is 8 kV, and the overvoltage category is III, enabling application in industrial environments with high transient voltages. The rated insulation voltage is 690 V for both the current circuit and signal circuit according to IEC 60947-4-1, ensuring high electrical safety. The insulation resistance exceeds 10 MΩ for the signal circuit, ensuring reliable electrical isolation.
Compatibility and Accessories
The contactor can be combined with various accessories to extend functionality. These include auxiliary switch blocks such as the LA1KN04 (4 NO contacts) or LA1KN11M (1 NC, 1 NO), used to expand control signals. Additionally, motor protection circuit breakers such as the GV2ME14 or GV2LE14 are available to protect the motor against overload and short circuit. Connection modules such as the LA4KC1B (special diode 12–24 VDC) can be used to adapt coil control. Mounting is either on a rail or a mounting plate, with tightening torques for the screw terminals ranging from 0.8 to 1.3 Nm.
Mounting and Installation
Mounting is done on a standard rail (DIN rail) or directly on a mounting plate. Connections are made via screw terminals designed for various cable cross-sections: for rigid cables from 1.5 to 4 mm², for flexible cables without wire end ferrules from 0.75 to 4 mm², and with wire end ferrules from 0.34 to 2.5 mm². The terminals are designed for connecting one or two cables, with the maximum number of cables per terminal varying depending on the cross-section. The operating time is 30 to 40 ms from coil energization to closure of the NO contact.
Advantages in Operation
The contactor is characterized by high reliability and long service life. The rated breaking capacity is up to 110 A at 220–440 V, enabling safe interruption of loads. The rated short-time current withstand is defined for various durations, with the circuit capable of withstanding up to 90 A for 1 second and up to 20 A for at least 15 minutes. The associated fuse rating is 25 A gG, ensuring safe protection of the contactor. Certifications according to UL and CSA confirm compliance with international safety standards.