| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | DC standard |
| [Uc] control circuit voltage | 24 V DC |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 16 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 16 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in W | 3 W (at 20 °C) |
| Hold-in power consumption in W | 3 W at 20 °C |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.10 Uc (at |
| Connections - terminals | Spring terminals 1 cable(s) 0.75…1.5 mm²solid; Spring terminals 1 cable(s) 0.75…1.5 mm²flexible without cable end; Spring terminals 2 cable(s) 0.75…1.5 mm²flexible without cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | With integral suppression device |
| Auxiliary contacts type | type instantaneous 1 NC |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting support | Plate; Rail |
| Operating time | 30...40 ms coil energisation and NO closing; 10 ms coil de-energisation and NO opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.225 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LP1K |
| Contactor application | Motor control; Resistive load |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.800 cm |
| Package 1 Width | 6.200 cm |
| Package 1 Length | 6.800 cm |
| Package 1 Weight | 224.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.422 kg |
The LP1K09013BD3 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electric motors and resistive loads in industrial, infrastructure, and building applications. It features an operating rating of 9 A at 400 V AC in usage category AC-3, enabling control of motors with a power of up to 4 kW at 380–415 V AC. The coil is designed for a control circuit voltage of 24 V DC, making it suitable for applications with DC control systems. The device is equipped with an integrated bidirectional amplitude-limiting diode that limits coil voltage during switching off, thereby increasing the coil's lifespan and enhancing the stability of the control circuit.
Applications
This contactor is designed for motor control in various application areas, including industrial machine controls, infrastructure installations, and building automation. It is suitable for loads in categories AC-1, AC-3, AC-3e, and AC-4, with AC-3 being the typical usage category for motor protection switches at medium switching frequency. Category AC-3e refers to controlling motors with high starting current load, while AC-4 is intended for high switching frequencies and high mechanical stress.
Functions and Equipment in Detail
The device features three normally open contacts in the main current circuit (3 S) and one additional non-delayed normally closed contact in the auxiliary contact circuit (1 Ö). The auxiliary contacts are used for signal transmission in control systems, e.g., to report the switching status to a PLC. The spring terminals allow connection of cables with a cross-section of 0.75 to 1.5 mm², both rigid and flexible, with up to two flexible cables connectable to one terminal. The maximum operating rate is 3600 switching operations per hour, suitable for frequent switching in automated systems.
Technology Explained Simply
The coil technology with integrated suppression unit reduces magnetic overvoltages during switching off and protects the control circuit from disturbances. The rated impulse voltage withstand is 8 kV, and overvoltage category III indicates suitability for installations with high electrical stress. The rated insulation voltage is 690 V for the current circuit and signal circuit according to IEC 60947-4-1, enabling use in industrial networks with high voltages. Insulation resistances are specified at over 10 MΩ for the signal circuit, ensuring high electrical safety.
Compatibility and Accessories
The contactor is compatible with various auxiliary switch blocks, including models such as LA1KN023 (2 NO), LA1KN113 (1 NC, 1 NO), LA1KN203 (2 NO), and LA1KN313 (3 NO, 1 NC). Additionally, delayed auxiliary switches such as LA2KT2U (30 s delay) or LA2KT2E (1–30 s delayed response) can be used to implement specific control logic. A nameplate (LA9D90) can be used for function identification. Mounting is either on a plate or on a rail, facilitating integration into existing control panels.
Mounting and Installation
Mounting is on a rail or plate, with device dimensions of 45 mm (width) × 58 mm (height) × 57 mm (depth). The spring terminals enable quick and secure cable connections. The operating time is 30–40 ms for coil energization and closing of the NO contact, and 10 ms for coil de-energization and opening of the NO contact. The device’s heat dissipation is 1.3 W, which should be considered when planning cooling in control enclosures.
Operational Advantages
The contactor offers a high mechanical life of 10 million switching cycles and an electrical life of 1.3 million cycles at 9 A AC-3. The B10d values are 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load, highlighting reliability under demanding operating conditions. Certifications according to UL and CSA ensure compliance with international safety standards. The simple interface for electronic devices such as PLCs enables direct integration into modern control systems.