Schneider Electric LP1D40008FD, EAN: 3389110234077

Schneider Electric LP1D40008FD contactor 4p 2S2Ö AC1 440V 60A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LP1D40008FD contactor 4p 2S2Ö AC1 440V 60A

Lieske Part No. 629672
Mfg Part No LP1D40008FD
EAN-Code 3389110234077
Manufacturer Schneider Electric
Here only 480,86 EUR
572,22 EUR incl. VAT

Further information for Schneider Electric LP1D40008FD contactor 4p 2S2Ö AC1 440V 60A

Complementary
Compatibility codeLP1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current60 A (at 60 °C) for power circuit
Irms rated making capacity800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current72 A 40 °C - 10 min for power circuit; 165 A 40 °C - 1 min for power circuit; 320 A 40 °C - 10 s for power circuit; 720 A 40 °C - 1 s for power circuit
Associated fuse rating80 A gG at
Average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole5.4 W AC-1
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.4 Mcycles 60 A AC-1 at Ue
Control circuit typeDC DC standard
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.3 Uc (-40…55 °C):drop-out DC; 0.85...1.1 Uc (-40…55 °C):operational DC
Inrush power in W22 W (at 20 °C)
Hold-in power consumption in W22 W at 20 °C
Operating time4...19 ms opening; 12...26 ms closing
Time constant75 ms
Maximum operating rate3600 cyc/h at 60 °C
Tightening torquePower circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 5 N.m - on screw clamp terminals - cable 1…25 mm² hexagonal screw head 4 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1
Product certificationsUL; CSA; CCC; EAC; UKCA; CB; DNV-GL; RINA; BV; LROS (Lloyds register of shipping)
IP degree of protectionIP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessShocks contactor open (8 Gn for 11 ms) ; Shocks contactor closed (10 Gn for 11 ms) ; Vibrations contactor opened (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz)
Height127 mm
Width85 mm
Depth182 mm
Net weight2.21 kg
Logistical informations
Country of originCZ
Main
RangeTeSys
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLP1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current60 A (at
[Uc] control circuit voltage110 V DC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height22.5 cm
Package 1 Width14.8 cm
Package 1 Length18.0 cm
Package 1 Weight2.4 kg
The contactor LP1D40008FD from the TeSys series by Schneider Electric is an industrial power switch designed for use in electrical installations with resistive loads. It features four poles (4P) and a contact configuration of two normally open and two normally closed contacts (2S+2Ö), making it suitable for applications with complex control requirements. The rated operational voltage is 440 V, and the rated operational current is 60 A, with usage category AC-1 defined. The control circuit voltage is 110 V DC, enabling use in systems with direct current supply. The coil is equipped with integrated bidirectional surge-limiting diode suppressor technology, which increases the coil's lifespan and reduces interference with control devices caused by voltage spikes.

Applications
This contactor is designed for use in industrial installations, particularly in applications with resistive loads, such as heaters, resistance brakes, or other consumers that do not represent inductive or capacitive loads. Usage category AC-1 specifies that the device is designed for operation with purely resistive loads. The rated insulation voltage is 690 V, allowing use in installations with higher voltages, and complies with standards IEC 60947-4-1 as well as UL and CSA. Overvoltage category III and pollution degree 3 indicate that the device is designed for environments with increased risk of overvoltage and contamination, such as production plants or industrial machinery.

Functions and Equipment in Detail
The device features a safety cover that prevents access to contacts and the coil during operation, thereby enhancing safety. The contact configuration of 2S+2Ö enables integration into complex control circuits where multiple switching operations must occur in parallel or sequentially. The rated making capacity is 800 A at 440 V, ensuring safe switching capability under high inrush currents. The rated breaking capacity is also designed for 800 A at 440 V, confirming the contactor's ability to interrupt load currents under these conditions.

Technology Explained Simply
The contactor coil is operated at 110 V DC, with the operating voltage required to be between 0.85 and 1.1 times the nominal voltage to ensure secure engagement. The release voltage is between 0.1 and 0.3 times the nominal voltage, enabling secure release of the contactor during voltage fluctuations. The pickup power is 22 W at 20 °C, and the holding power consumption is also 22 W, indicating constant power draw during operation. The operating time is 4 to 19 ms for opening and 12 to 26 ms for closing, ensuring fast responsiveness of the device. The time constant of 75 ms influences switching behavior and stability of the contactor under dynamic load changes.

Compatibility and Accessories
The contactor is compatible with various accessories that extend its functionality. These include auxiliary switch blocks such as LADN04 (4Ö) or LADN22 (2S+2Ö), which provide additional switching functions for control circuits. Time delay blocks such as LADT2 (1S+1Ö, 0.10–30.00 s) or LADT4 (1S+1Ö, 10.00–180.00 s) enable delayed switching operations. Additionally, overvoltage limiters such as LA4-DC3U (24–250 V DC) are available to protect the coil from transient voltage spikes. Mounting is possible either on a plate or on a rail, enabling flexible installation in enclosures.

Mounting and Installation
Mounting is done on a plate or rail, with screw terminals for power circuits requiring a torque of 5 Nm (for cables 1–25 mm²) or 8 Nm (for cables 25–35 mm²). Control circuit terminals require a torque of 1.7 Nm, with installation performed using either a flat screwdriver Ø 6 or a Phillips No. 2. The device ambient temperature range is -40 to 60 °C, with performance reduction required at temperatures from 60 to 70 °C. The operating altitude is limited to 0 to 3,000 m, allowing use in high-altitude installations or aircraft. The front protection rating IP20 corresponds to IEC 60529 and protects against finger contact, but not against dust or water.

Advantages in Operation
The mechanical life is 10 million switching cycles, while the electrical life at 60 A AC-1 and nominal voltage is 1.4 million switching cycles. The maximum operating rate is 3,600 switching operations per hour at 60 °C, enabling high load capacity in continuously operated installations. Flame retardancy V1 according to UL 94 and fire resistance of 850 °C according to IEC 60695-2-1 enhance safety in case of fire. Mechanical robustness against shocks (8 Gn open, 10 Gn closed) and vibrations (2 Gn open, 4 Gn closed) ensures reliable function even in vibrating environments. Certifications according to UL, CSA, CCC, EAC, UKCA, CB, DNV-GL, RINA, BV, and LROS (Lloyds Register of Shipping) confirm compliance with international safety and quality standards.