Schneider Electric LC2K1210D7, EAN: 3389118096004

Schneider Electric LC2K1210D7 contactor 3p 1S 5

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2K1210D7 contactor 3p 1S 5

Lieske Part No. 508109
Mfg Part No LC2K1210D7
EAN-Code 3389118096004
Manufacturer Schneider Electric
Here only 142,98 EUR
170,15 EUR incl. VAT

Further information for Schneider Electric LC2K1210D7 contactor 3p 1S 5

Complementary
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Auxiliary contacts typetype instantaneous 1 NO
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non overlap distance0.5 mm
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to VDE 0106
Protective treatmentTC conforming to IEC 60068; TC conforming to DIN 50016
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Height58 mm
Width90 mm
Depth57 mm
Net weight0.39 kg
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys K
Product or component typeReversing contactor
Device short nameLC2K
Device applicationControl
Contactor applicationResistive load; Motor control
Utilisation categoryAC-1; AC-4; AC-3; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: 690 V AC 50/60 Hz; Signalling circuit:
[Ie] rated operational current20 A (at
Motor power kW4 kW at 480 V AC 50/60 Hz; 4 kW at 500...600 V AC 50/60 Hz; 4 kW at 660...690 V AC 50/60 Hz; 3 kW at 220...230 V AC 50/60 Hz; 5.5 kW at 380...415 V AC 50/60 Hz; 5.5 kW at 440 V AC 50/60 Hz
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage42 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity144 A at 690 V AC for power circuit conforming to NF C 63-110; 144 A at 690 V AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit; 105 A 50 °C - 5 s for power circuit; 100 A 50 °C - 10 s for power circuit; 75 A 50 °C - 30 s for power circuit; 55 A 50 °C - 1 min for power circuit; 50 A 50 °C - 3 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit; 25 A 50 °C - >= 15 min for power circuit
Associated fuse rating25 A gG at
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability1.3 Mcycles 12 A AC-3 at Ue
Interlocking typeMechanical
Mounting supportRail; Plate
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1
Product certificationsCB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time10...20 ms coil energisation and NO closing; 10...20 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability5 Mcycles
Maximum operating rate3600 cyc/h
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.000 cm
Package 1 Width9.200 cm
Package 1 Length6.200 cm
Package 1 Weight390.000 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight15.860 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight261.760 kg
3-pole TeSys K reversing contactor for motor applications up to 5.5kW@400V. It features 42V 50/60Hz AC coils, integrated 2NO auxiliary contacts, screw terminal connection, pre-wired reversing circuits, mechanical interlock. Compact DIN rail mounting and screw fixing ensure reliability and durability in standard applications. Certified with multiple standards (IEC, UL, CSA, CCC, EAC) and Green Premium (RoHs/Reach).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/508109
qrcode für Schneider Electric LC2K1210D7 contactor 3p 1S 5