| Complementary |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Auxiliary contacts type | type instantaneous 1 NO |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Non overlap distance | 0.5 mm |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20 conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Height | 58 mm |
| Width | 90 mm |
| Depth | 57 mm |
| Net weight | 0.39 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product name | TeSys K |
| Product or component type | Reversing contactor |
| Device short name | LC2K |
| Device application | Control |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-4; AC-1 |
| Device presentation | Preassembled with reversing power busbar |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz; Signalling circuit: |
| [Ie] rated operational current | 9 A (at |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz; 4 kW at 380...415 V AC 50/60 Hz; 4 kW at 440/690 V AC 50/60 Hz |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Interlocking type | Mechanical |
| Mounting support | Rail; Plate |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 10...20 ms coil energisation and NO closing; 10...20 ms coil de-energisation and NO opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 5 Mcycles |
| Maximum operating rate | 3600 cyc/h |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 9.000 cm |
| Package 1 Length | 6.000 cm |
| Package 1 Weight | 368.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 25 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.415 kg |
The
reversing contactor LC2K0910P7 from the
TeSys series by
Schneider Electric is a 3-pole contactor for controlling electric drives and resistive loads. The device is designed as a
reversing contactor, with the main circuit wiring pre-assembled and an integrated reversing power busbar. It is particularly suitable for motor control applications in industrial plants, with a rated power of 4 kW depending on the operating voltage (380–415 V AC 50/60 Hz or 440–690 V AC 50/60 Hz). At 220–230 V AC 50/60 Hz, the motor power is 2.2 kW. The rated operating voltage of the main circuit is 690 V AC, and the control circuit voltage is 230 V AC 50/60 Hz. The contactor coil is designed for this voltage, ensuring operation within the voltage range of 0.8 to 1.15 times the nominal voltage.
Applications include controlling electric motors in production plants, conveyor systems, or pumps where reversible rotation is required. The device is approved for usage categories AC-3, AC-3e, AC-4, and AC-1, enabling use with inductive loads such as motors and resistive loads. The mechanical interlock ensures safe and reliable switching between positions, preventing simultaneous closure of both main contacts.
Functions and equipment in detail include an integrated auxiliary contact in normally open configuration (1 S), which can be used for control tasks such as signal transmission or feedback. The connection terminals are screw terminals, allowing connection of cables with cross-sections of 1.5 to 4 mm² (rigid), 0.75 to 4 mm² (flexible without cable end), and 0.34 to 2.5 mm² (flexible with cable end). The tightening torques range from 0.8 to 1.3 Nm, and the screw terminals are operated using a Phillips screwdriver No. 2, flat screwdriver Ø 6, or position No. 2. The device width is 90 mm, making it suitable for mounting on a rail or panel.
Technology explained simply shows that the contactor has a rated voltage of 690 V AC in the main circuit and an insulation strength of 690 V according to IEC 60947-4-1. The impulse voltage withstand is 8 kV, and the overvoltage category is III, enabling use in industrial environments with high transient voltages. The conventional thermal current is 20 A in the main circuit (at 60 °C) and 10 A in the signal circuit (at 50 °C). The rated breaking capacity is 110 A at 220–230 V and 380–415 V, and 70 A at 660–690 V. The rated short-time withstand current is defined for various time intervals, with values of 90 A (1 s) to 20 A (≥15 min) for the main circuit. The electrical life is 1.3 million switching cycles at 9 A AC-3, and the mechanical life is 5 million cycles. The maximum operating rate is 3600 cycles per hour.
Compatibility and accessories include the option to extend the device with additional auxiliary switches. Expansion is possible up to four auxiliary contacts per pole. Compatible accessories include auxiliary switch blocks such as LA1KN04 (4 NO), LA1KN02 (2 NO), LA1KN11M (1 NC, 1 NO), LA1KN22 (2NO+2NC), LA1KN31 (3NO+1NC), LA1KN40 (4 NC), LA1KN20 (2 NC), LA1KN13 (1NO+3NC), LA1KN22M (2 NC), LA1KN31M (3NO+1NC), as well as delayed auxiliary switches such as LA2KT2U (30 s) and LA2KT2E (1–30 s). Other components include motor protection circuit breakers such as GV2ME14 (6–10 A, push-button operation) or GV2LE14 (10 A, magnetic trip), motor protection relays such as LR2K0314 (5.5–8.0 A) or LR2K0316 (8.0–11.5 A), overvoltage limiters such as LA4KA1U (220–250 V) or LA4KE1UG (250 V), and an energy meter A9MEM1573. The associated fuse is specified as 25 A gG.
Mounting and installation is done via rail or panel, with the device width of 90 mm enabling compact placement. The pre-assembled main circuit wiring reduces installation time and minimizes error sources. The screw terminals are designed for various cable types, allowing flexible wiring. The operating time is 10–20 ms for coil energization and NO closure, as well as for coil de-energization and NO opening.
Operational advantages include high service life, mechanical interlock, pre-assembled wiring, and expandability with auxiliary switches. Certifications according to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, JIS C8201-4-1, and GB/T 14048.4, as well as product certifications CB Scheme, CCC, UL, CSA, EAC, CE, and UKCA, ensure compliance with international standards. The safety level corresponds to EN/ISO 13849-1 with a B10d value of 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load.
The device is designed for use in industrial control systems where reliability, high switching cycles, and safe switching are important. The combination of integrated auxiliary contact, pre-assembled wiring, and expandability makes it a flexible component in complex plant control systems.