Additional features
Control circuit voltage limitsOperation: 0.8 - 1.15 Uc (at
Input power in VA30 VA (at 20 °C)
Hold power consumption in VA4.5 VA (at 20 °C)
Heat emission1,3 W
Type of auxiliary contactsType instantaneous 1 NC
Min. switching current5 mA for signal circuit
Min. switching voltage17 V for signal circuit
Non-overlapping distance0,5 mm
Insulation resistance> 10 MΩ for signal circuits
Contractual warranty
Warranty (in months)18
Main features
Product seriesTeSys
Product nameTeSys K
Product or component typeReversing safety
Device short nameLC2K
Device applicationControl
Application of contactorMotor control; resistive load
Application categoryAC-1; AC-4; AC-3; AC-3e
Device representationPre-fabricated with reversing power busbar
Pole description3P
Pole contact composition3 S
[Ue] Rated operational voltageCircuit: 690 V AC 50/60 Hz; Signal circuit:
[Ie] rated operational current20 A (at
Motor power (kW)2.2 kW at 220 - 230 V AC 50/60 Hz; 4 kW at 380 - 415 V AC 50/60 Hz; 4 kW at 440 V AC 50/60 Hz; 4 kW at 480 V AC 50/60 Hz; 4 kW at 500 - 600 V AC 50/60 Hz; 4 kW at 660 - 690 V AC 50/60 Hz
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Configuration of auxiliary contacts1 Ö
[Uimp] Rated impulse voltage withstand8 kV
Over voltage categoryIII
[Ith] conventional thermal current in free air20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signal circuit
[Irms] Rated making capacity110 A AC for circuit conforming to NF C 63-110; 110 A AC for circuit conforming to IEC 60947; 110 A AC for signal circuit conforming to IEC 60947
Rated breaking capacity110 A at 415 V corresponds to IEC 60947; 110 A at 440 V corresponds to IEC 60947; 80 A at 500 V corresponds to IEC 60947; 110 A at 220 - 230 V corresponds to IEC 60947; 110 A at 380 - 400 V corresponds to IEC 60947; 70 A at 660 - 690 V corresponds to IEC 60947
[Icw] rated short-time current withstand90 A 50 °C - 1 s for circuit; 85 A 50 °C - 5 s for circuit; 80 A 50 °C - 10 s for circuit; 60 A 50 °C - 30 s for circuit; 45 A 50 °C - 1 min for circuit; 40 A 50 °C - 3 min for circuit; 80 A - 1 s for signal circuit; 90 A - 500 ms for signal circuit; 110 A - 100 ms for signal circuit; 20 A 50 °C - >= 15 min. for circuit
Associated fuse25 A gG at
Average impedance3 MOhm - Ith 20 A 50 Hz for circuit
[Ui] Rated insulation voltageCircuit: 600 V complies with UL 508; Circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-5-1; Signal circuit: 600 V complies with UL 508; Circuit: 600 V complies with CSA C22.2 No. 14; Signal circuit: 600 V complies with CSA C22.2 No. 14
Electrical lifetime1.3 Mcycles 9 A AC-3 at Ue
Locking typeMechanical
Mounting bracketRail; Plate
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No. 60947-4-1; JIS C8201-4-1
Product certificationsCB certification; CCC; UL; CSA; EAC; CE; UKCA
Connections - terminalsSolder pins (outer diameter: 0.035 mm)
Operating time10 - 20 ms coil energizing and NO closing; 10 - 20 ms coil de-energizing and NO opening
Security level ratingB10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1
Mechanical life5 Mcycles
Max. operating rate3600 cyc/h
Mounting
Degree of protection (IP)IP20 corresponds to VDE 0106
CoatingTC corresponds to IEC 60068; TC corresponds to DIN 50016
Operating ambient temperature-25…50 °C
Ambient temperature during storage-50…80 °C
Operating altitude2,000 m without derating
Flame retardancyV1 corresponds to UL 94; Requirement 2 corresponds to NF F 16-101; Requirement 2 corresponds to NF F 16-102
Height58 mm
Width90 mm
Depth57 mm
Product weight0,39 kg
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height6,200 cm
VPE 1 width6,700 cm
VPE 1 length9,300 cm
Packaging weight (Lbs)404,000 g
3-pole reversing contactor TeSys K for motor applications up to 4kW@400V. It offers 230 V 50/60 Hz AC coils, integrated auxiliary contacts 2NC, connection via solder pins for printed circuit boards (without pre-wired reversing circuit), mechanical interlock. Available worldwide, certified with several standards (IEC, UL, CSA, CCC, EAC) and Green Premium (RoHs/Reach).