Schneider Electric LC2K09015E7, EAN: 3389110492071

Schneider Electric LC2K09015E7 contactor 3p 48V 50/60Hz

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2K09015E7 contactor 3p 48V 50/60Hz

Lieske Part No. 586234
Mfg Part No LC2K09015E7
EAN-Code 3389110492071
Manufacturer Schneider Electric
Here only 127,78 EUR
152,06 EUR incl. VAT

Further information for Schneider Electric LC2K09015E7 contactor 3p 48V 50/60Hz

Complementary
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Auxiliary contacts typetype instantaneous 1 NC
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non overlap distance0.5 mm
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to VDE 0106
Protective treatmentTC conforming to IEC 60068; TC conforming to DIN 50016
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Height58 mm
Width90 mm
Depth57 mm
Net weight0.39 kg
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys K
Product or component typeReversing contactor
Device short nameLC2K
Device applicationControl
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-4; AC-1; AC-3; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: 690 V AC 50/60 Hz; Signalling circuit:
[Ie] rated operational current20 A (at
Motor power kW2.2 kW at 220...230 V AC 50/60 Hz; 4 kW at 380...415 V AC 50/60 Hz; 4 kW at 440 V AC 50/60 Hz; 4 kW at 480 V AC 50/60 Hz; 4 kW at 500...600 V AC 50/60 Hz; 4 kW at 660...690 V AC 50/60 Hz
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage48 V AC 50/60 Hz
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to NF C 63-110; 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit; 20 A 50 °C - >= 15 min for power circuit
Associated fuse rating25 A gG at
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability1.3 Mcycles 9 A AC-3 at Ue
Interlocking typeMechanical
Mounting supportPlate; Rail
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1
Product certificationsCB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Connections - terminalsSolder pins (external diameter: 0.035 mm)
Operating time10...20 ms coil energisation and NO closing; 10...20 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability5 Mcycles
Maximum operating rate3600 cyc/h
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width9.300 cm
Package 1 Length6.000 cm
Package 1 Weight402.000 g
Unit Type of Package 2S02
Number of Units in Package 225
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.317 kg
Unit Type of Package 3P06
Number of Units in Package 3400
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight177.392 kg
3-pole reversing contactor TeSys K for motor applications up to 4kW@400V. It features 48 V 50/60 Hz AC coils, built-in 2NC auxiliary contacts, connection via solder pins for printed circuit boards (without pre-wired reversing circuit), mechanical interlock. Available worldwide, certified with multiple standards (IEC, UL, CSA, CCC, EAC) and Green Premium (RoHs/Reach).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter: