| Additional features |
| Coil technology | Integrated bidirectional transient voltage suppressor diodes |
| Control circuit voltage limits | Operation: 0.8 - 1.15 Uc (at |
| Input power in VA | 30 VA (at 20 °C) |
| Hold power consumption in VA | 4.5 VA (at 20 °C) |
| Heat emission | 1,3 W |
| Type of auxiliary contacts | Type instantaneous 1 NC |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Non-overlapping distance | 0,5 mm |
| Insulation resistance | > 10 MΩ for signal circuits |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys |
| Product name | TeSys K |
| Product or component type | Reversing safety |
| Device short name | LC2K |
| Device application | Control |
| Application of contactor | Motor control |
| Application category | AC-4; AC-3; AC-3e |
| Device representation | Pre-fabricated with reversing power busbar |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: 690 V AC 50/60 Hz; Signal circuit: |
| [Ie] rated operational current | 6 A at |
| Motor power (kW) | 1.5 kW at 220 - 230 V AC 50/60 Hz; 2.2 kW at 380 - 415 V AC 50/60 Hz; 3 kW at 440 V AC 50/60 Hz; 3 kW at 480 V AC 50/60 Hz; 3 kW at 500 - 600 V AC 50/60 Hz; 3 kW at 660 - 690 V AC 50/60 Hz |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| Configuration of auxiliary contacts | 1 Ö |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signal circuit |
| [Irms] Rated making capacity | 110 A AC for circuit conforming to NF C 63-110; 110 A AC for circuit conforming to IEC 60947; 110 A AC for signal circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 415 V corresponds to IEC 60947; 110 A at 440 V corresponds to IEC 60947; 80 A at 500 V corresponds to IEC 60947; 110 A at 220 - 230 V corresponds to IEC 60947; 110 A at 380 - 400 V corresponds to IEC 60947; 70 A at 660 - 690 V corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 90 A 50 °C - 1 s for circuit; 85 A 50 °C - 5 s for circuit; 80 A 50 °C - 10 s for circuit; 60 A 50 °C - 30 s for circuit; 45 A 50 °C - 1 min for circuit; 40 A 50 °C - 3 min for circuit; 80 A - 1 s for signal circuit; 90 A - 500 ms for signal circuit; 110 A - 100 ms for signal circuit; 20 A 50 °C - >= 15 min. for circuit |
| Associated fuse | 25 A gG at |
| Average impedance | 3 MOhm - Ith 20 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 600 V complies with UL 508; Circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-5-1; Signal circuit: 600 V complies with UL 508; Circuit: 600 V complies with CSA C22.2 No. 14; Signal circuit: 600 V complies with CSA C22.2 No. 14 |
| Electrical lifetime | 1.3 Mcycles 6 A AC-3 at Ue |
| Locking type | Mechanical |
| Mounting bracket | Rail; Plate |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No. 60947-4-1; JIS C8201-4-1 |
| Product certifications | CB certification; CCC; UL; CSA; EAC; CE; UKCA |
| Connections - terminals | Screw terminals 1 cable(s) 1.5…4 mm² solid; screw terminals 1 cable(s) 0.75…4 mm² stranded without ferrule; screw terminals 1 cable(s) 0.34…2.5 mm² stranded with ferrule; screw terminals 2 cable(s) 1.5…4 mm² solid; screw terminals 2 cable(s) 0.75…4 mm² stranded without ferrule; screw terminals 2 cable(s) 0.34…1.5 mm² stranded with ferrule |
| Tightening moment | 0.8…1.3 Nm - on screw terminals Phillips No. 2; 0.8…1.3 Nm - on screw terminals flat Ø 6; 0.8…1.3 Nm - on screw terminals position No. 2 |
| Operating time | 10 - 20 ms coil energizing and NO closing; 10 - 20 ms coil de-energizing and NO opening |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 5 Mcycles |
| Max. operating rate | 3600 cyc/h |
| Mounting |
| Degree of protection (IP) | IP20 corresponds to VDE 0106 |
| Coating | TC corresponds to IEC 60068; TC corresponds to DIN 50016 |
| Operating ambient temperature | -25…50 °C |
| Ambient temperature during storage | -50…80 °C |
| Operating altitude | 2,000 m without derating |
| Flame retardancy | V1 corresponds to UL 94; Requirement 2 corresponds to NF F 16-101; Requirement 2 corresponds to NF F 16-102 |
| Height | 58 mm |
| Width | 90 mm |
| Depth | 57 mm |
| Product weight | 0,39 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 6,200 cm |
| VPE 1 width | 6,800 cm |
| VPE 1 length | 9,300 cm |
| Packaging weight (Lbs) | 366,000 g |
3-pole reversing contactor TeSys K for motor applications up to 2.2 KW@400V. It offers 230V 50/60Hz AC coils with surge protection, built-in 2NC auxiliary contacts, screw terminal connection, pre-wired reversing circuit, mechanical interlock. Compact DIN rail mounting and screw fixing ensure reliability and durability in standard applications. Certified with multiple standards (IEC, UL, CSA, CCC, EAC) and Green Premium (RoHs/Reach).