Schneider Electric LC2D80AKUE, EAN: 3606481309419

Schneider Electric LC2D80AKUE contactor 3p+1S+1Ö

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2D80AKUE contactor 3p+1S+1Ö

Lieske Part No. 1861759
Mfg Part No LC2D80AKUE
EAN-Code 3606481309419
Manufacturer Schneider Electric
Here only 1.327,15 EUR
1.579,31 EUR incl. VAT

Further information for Schneider Electric LC2D80AKUE contactor 3p+1S+1Ö

Additional features
Coil technologyIntegrated bidirectional surge limiting
Type of auxiliary contactsMechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1
Signalling angular frequency25 - 400 Hz
Min. switching current5 mA for signal circuit
Min. switching voltage17 V for signal circuit
Non-overlapping time1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact
Insulation resistance> 10 MΩ for signal circuits
Contractual warranty
Warranty (in months)18
Main features
Product nameTeSys Deca Advanced
Product or component typeReversing safety
Device short nameLC2D
Application of contactorResistive load; motor control
Application categoryAC-1; AC-3; AC-3e
Device representationPre-fabricated with reversing power busbar
Pole description3P
Pole contact composition3 S
[Ue] Rated operational voltageCircuit: 690 V AC 25 - 400 Hz
[Ie] rated operational current80 A (at
Motor power (kW)18.5 kW at 220 - 230 V AC 50 Hz; 37 kW at 380 - 400 V AC 50 Hz; 37 kW at 415 V AC 50 Hz; 37 kW at 440 V AC 50 Hz; 37 kW at 500 V AC 50 Hz; 37 kW at 660 - 690 V AC 50 Hz
Control circuit typeAC at 50/60 Hz AC/DC, electronic; DC AC/DC, electronic
[Uc] control circuit voltage100 - 250 V AC 50/60 Hz; 100 - 250 V DC
Configuration of auxiliary contacts1 S + 1 Ö
[Uimp] Rated impulse voltage withstand6 kV corresponds to IEC 60947
Over voltage categoryIII
[Ith] conventional thermal current in free air10 A (at 60 °C) for signal circuit; 80 A (at 60 °C) for power circuit
[Irms] Rated making capacity140 A AC for signal circuit conforming to IEC 60947-5-1; 250 A DC for signal circuit conforming to IEC 60947-5-1; 1000 A at 440 V for circuit conforming to IEC 60947
Rated breaking capacity1000 A at 440 V for circuit, corresponds to IEC 60947
[Icw] rated short-time current withstand100 A - 1 s for signal circuits; 120 A - 500 ms for signal circuits; 140 A - 100 ms for signal circuits; 520 A 40 °C - 10 s for power circuits; 900 A 40 °C - 1 s for power circuits; 110 A 40 °C - 10 min for power circuits; 260 A 40 °C - 1 min for power circuits
Associated fuse10 A gG for signal circuit in accordance with IEC 60947-5-1; 125 A gG at
Average impedance1.5 MOhm - Ith 80 A 50 Hz for circuit
[Ui] Rated insulation voltageCircuit: 690 V according to IEC 60947-4-1; Signal circuit: 690 V according to IEC 60947-1
Power dissipation per pole9,6 W AC-1; 6,5 W AC-3; 6,5 W AC-3e
Front coverWith
Locking typeMechanical
Mounting bracketPlate; rail
Tightening momentControl circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Power circuit: 8 Nm - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 Nm - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
Security level ratingB10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1
Max. operating rate3600 cyc/h 60 °C
Mounting
Degree of protection (IP)IP20 front side corresponds to IEC 60529
Climate resistanceComplies with IACS E10; complies with IEC 60947-1 Annex Q Category D
CoatingTH corresponds to IEC 60068-2-30
Pollution degree3
Operating ambient temperature-40…60 °C; 60…70 °C with power reduction
Ambient temperature during storage-60…80 °C
Operating altitude0 - 3.000 m
Fire-resistance850 °C corresponds to IEC 60695-2-1
Mechanical robustnessVibrations contactor open: 2 Gn, 5 - 300 Hz; Vibrations contactor closed: 4 Gn, 5 - 300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms
Height122 mm
Width119 mm
Depth120 mm
Product weight2,174 kg
ColourGrey (SE GRAU 6); Green (SE GRÜN 2)
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height14,900 cm
VPE 1 width20,000 cm
VPE 1 length16,800 cm
Packaging weight (Lbs)2,046 kg
VPE 2 typeS03
VPE 2 quantity4
VPE 2 height30,000 cm
VPE 2 width30,000 cm
VPE 2 length40,000 cm
VPE 2 weight10,137 kg
Reversing contactor combination with electronic wide-range control for the highest requirements - TeSys D. 3-phase, rated current 80A for a motor output of up to 45kW at 400V AC3 and a supply voltage of 100-250V AC/DC. Compliant with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2, No 60947-4-1, EN/IEC 60947-5-1 and certified according to CCC, CSA, UL, EAC. Features such as low-maintenance EverLink terminal technology (removable) and two integrated auxiliary contacts usable for safety applications, optimized width. For the highest requirements in the field of switching technology. Can be used for loads of all energy efficiency classes IE0 - IE4. In combination with TeSys GV3 or LR.D they become an extremely compact reversing starter.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1861759
qrcode für Schneider Electric LC2D80AKUE contactor 3p+1S+1Ö