| Additional features |
| Coil technology | Integrated bidirectional surge limiting |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Insulation resistance | > 10 MΩ for signal circuits |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product name | TeSys Deca Advanced |
| Product or component type | Reversing safety |
| Device short name | LC2D |
| Application of contactor | Resistive load; motor control |
| Application category | AC-1; AC-3; AC-3e |
| Device representation | Pre-fabricated with reversing power busbar |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: 690 V AC 25 - 400 Hz |
| [Ie] rated operational current | 80 A (at |
| Motor power (kW) | 18.5 kW at 220 - 230 V AC 50 Hz; 37 kW at 380 - 400 V AC 50 Hz; 37 kW at 415 V AC 50 Hz; 37 kW at 440 V AC 50 Hz; 37 kW at 500 V AC 50 Hz; 37 kW at 660 - 690 V AC 50 Hz |
| Control circuit type | DC low power consumption |
| [Uc] control circuit voltage | 24 V DC |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947 |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for signal circuit; 80 A (at 60 °C) for power circuit |
| [Irms] Rated making capacity | 140 A AC for signal circuit conforming to IEC 60947-5-1; 250 A DC for signal circuit conforming to IEC 60947-5-1; 1000 A at 440 V for circuit conforming to IEC 60947 |
| Rated breaking capacity | 1000 A at 440 V for circuit, corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 100 A - 1 s for signal circuits; 120 A - 500 ms for signal circuits; 140 A - 100 ms for signal circuits; 520 A 40 °C - 10 s for power circuits; 900 A 40 °C - 1 s for power circuits; 110 A 40 °C - 10 min for power circuits; 260 A 40 °C - 1 min for power circuits |
| Associated fuse | 10 A gG for signal circuit in accordance with IEC 60947-5-1; 125 A gG at |
| Average impedance | 1.5 MOhm - Ith 80 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 690 V according to IEC 60947-4-1; Signal circuit: 690 V according to IEC 60947-1 |
| Power dissipation per pole | 9,6 W AC-1; 6,5 W AC-3; 6,5 W AC-3e |
| Front cover | With |
| Locking type | Mechanical |
| Mounting bracket | Rail; Plate |
| Tightening moment | Control circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Power circuit: 8 Nm - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 Nm - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Max. operating rate | 3600 cyc/h 60 °C |
| Mounting |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Climate resistance | Complies with IACS E10; complies with IEC 60947-1 Annex Q Category D |
| Coating | TH corresponds to IEC 60068-2-30 |
| Pollution degree | 3 |
| Operating ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Ambient temperature during storage | -60…80 °C |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open: 2 Gn, 5 - 300 Hz; Vibrations contactor closed: 4 Gn, 5 - 300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms |
| Height | 122 mm |
| Width | 119 mm |
| Depth | 120 mm |
| Product weight | 2,174 kg |
| Colour | Grey (SE GRAU 6); Green (SE GRÜN 2) |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 14,400 cm |
| VPE 1 width | 19,700 cm |
| VPE 1 length | 16,500 cm |
| Packaging weight (Lbs) | 2,054 kg |
Reversing contactor combination with electronic control for the highest requirements - TeSys D. 3-phase, rated current 80A for a motor power of up to 45kW at 400V AC3 and a supply voltage of 24DC (500mA) optimized for PLC outputs. Conforms to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2, No 60947-4-1, EN/IEC 60947-5-1 and certified according to CCC, CSA, UL, EAC. Features such as low-maintenance EverLink terminal technology (removable) and two integrated auxiliary contacts usable for safety applications, optimized width. For the highest requirements in the field of switching technology. Can be used for loads of all energy efficiency classes IE0 - IE4. In combination with TeSys GV3 or LR.D they become an extremely compact reversing starter.