Schneider Electric LC2D38P7, EAN: 3389110391954

Schneider Electric LC2D38P7 contactor 230 VAC

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2D38P7 contactor 230 VAC

Lieske Part No. 567826
Mfg Part No LC2D38P7
EAN-Code 3389110391954
Manufacturer Schneider Electric
Here only 421,97 EUR
502,14 EUR incl. VAT

Further information for Schneider Electric LC2D38P7 contactor 230 VAC

Complementary
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandconforming to IACS E10; conforming to IEC 60947-1 Annex Q category D
Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C; 60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor closed: 15 Gn for 11 ms; Shocks contactor open: 8 Gn for 11 ms
Height85 mm
Width90 mm
Depth92 mm
Net weight0.807 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys D; TeSys Deca
Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-3; AC-1; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current50 A (at
Motor power kW9 kW at 220...230 V AC 50...60 Hz; 18.5 kW at 380...400 V AC 50...60 Hz; 18.5 kW at 415 V AC 50...60 Hz; 18.5 kW at 440 V AC 50...60 Hz; 18.5 kW at 500 V AC 50...60 Hz; 18.5 kW at 660...690 V AC 50...60 Hz
Motor power hp5 hp at 240 V AC 60 Hz for 1 phase motors
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 50 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current60 A 40 °C - 10 min for power circuit; 430 A 40 °C - 1 s for power circuit; 150 A 40 °C - 1 min for power circuit; 310 A 40 °C - 10 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at
Average impedance2 mOhm - Ith 50 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Electrical durability1.4 Mcycles 50 A AC-1 at Ue
Power dissipation per pole5 W AC-1; 3 W AC-3; 3 W AC-3e
Front coverWith
Interlocking typeMechanical
Mounting supportRail; Plate
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1
Product certificationsUL; CSA; RINA; GOST; CCC; DNV; LROS (Lloyds register of shipping); GL; BV; UKCA; CB
Operating time12...22 ms closing; 4...19 ms opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Maximum operating rate3600 cyc/h 60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height13.5 cm
Package 1 Width11.4 cm
Package 1 Length11.4 cm
Package 1 Weight943.0 g
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.984 kg
3-pole TeSys D reversing contactor for motor applications up to 18.5kW@400V. It offers 230 V 50/60 Hz AC coils, integrated auxiliary contacts 2NO+2NC (mirror contacts) and power and control connections via screw terminals. Equipped with pre-wired power connections with 2 directions of rotation and mechanical interlock. Compact (90 mm wide), DIN rail mounted, it ensures high reliability and durability. It has multiple standards (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliance (RoHs/Reach).