| Additional features |
| Coil technology | Without integrated switching module |
| Control circuit voltage limits | 0.3 - 0.6 Uc (-40…70 °C): drop-out voltage AC 50/60 Hz; 0.8 - 1.1 Uc (-40…60 °C): operation AC 50 Hz; 0.85 - 1.1 Uc (-40…60 °C): operation AC 60 Hz; 1 - 1.1 Uc (60…70 °C): operation AC 50/60 Hz |
| Input power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat emission | 2…3 W at 50/60 Hz |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Insulation resistance | > 10 MΩ for signal circuits |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys; TeSys Deca |
| Product name | TeSys Deca; TeSys Deca |
| Product or component type | Reversing safety |
| Device short name | LC2D |
| Application of contactor | Motor control; resistive load |
| Application category | AC-3; AC-1 |
| Device representation | Pre-fabricated with reversing power busbar |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 32 A (at |
| Motor power (kW) | 7.5 kW at 220 - 230 V AC 50 Hz; 15 kW at 380 - 400 V AC 50 Hz; 15 kW at 415 - 440 V AC 50 Hz; 18.5 kW at 500 V AC 50 Hz; 18.5 kW at 660 - 690 V AC 50 Hz |
| Motor power HP (UL / CSA) | 2 hp at 115 V AC 60 Hz for 1-phase motors; 5 hp at 230/240 V AC 60 Hz for 1-phase motors; 7.5 hp at 200/208 V AC 60 Hz for 3-phase motors; 10 hp at 230/240 V AC 60 Hz for 3-phase motors; 20 hp at 460/480 V AC 60 Hz for 3-phase motors; 30 hp at 575/600 V AC 60 Hz for 3-phase motors |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 120 V AC 50/60 Hz |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947 |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for signal circuit; 50 A (at 60 °C) for power circuit |
| [Irms] Rated making capacity | 140 A AC for signal circuits conforming to IEC 60947-5-1; 250 A DC for signal circuits conforming to IEC 60947-5-1; 550 A at 440 V for power circuits conforming to IEC 60947 |
| Rated breaking capacity | 550 A at 440 V for circuit, corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 60 A 40 °C - 10 min for circuit; 138 A 40 °C - 1 min for circuit; 260 A 40 °C - 10 s for circuit; 430 A 40 °C - 1 s for circuit; 100 A - 1 s for signal circuit; 120 A - 500 ms for signal circuit; 140 A - 100 ms for signal circuit |
| Associated fuse | 10 A gG for signal circuit, compliant with IEC 60947-5-1; 63 A gG at |
| Average impedance | 2 MOhm - Ith 50 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 690 V compliant with IEC 60947-4-1; Circuit: 600 V CSA certified; Circuit: 600 V UL certified; Signal circuit: 690 V compliant with IEC 60947-1; Signal circuit: 600 V CSA certified; Signal circuit: 600 V UL certified |
| Electrical lifetime | 1.65 Mcycles 32 A AC-3 at Ue |
| Power dissipation per pole | 2 W AC-3; 5 W AC-1 |
| Front cover | With |
| Locking type | Electrical and mechanical |
| Mounting bracket | Plate; rail |
| Standards | CSA C22.2 No. 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1 |
| Product certifications | UL; CSA; RINA; GOST; CCC; DNV; LROS (Lloyds register of shipping); GL; BV; UKCA; CB |
| Tightening moment | Control circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Power circuit: 2.5 Nm - on screw terminals - with flat screwdriver Ø 6; Power circuit: 2.5 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with screwdriver position No. 2; Power circuit: 2.5 Nm - on screw terminals - with screwdriver position No. 2 |
| Operating time | 12 - 22 ms closing; 4 - 19 ms opening |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 15 Mcycles |
| Max. operating rate | 3600 cyc/h 60 °C |
| Mounting |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Climate resistance | Complies with IACS E10; complies with IEC 60947-1 Annex Q Category D |
| Coating | TH corresponds to IEC 60068-2-30 |
| Pollution degree | 3 |
| Operating ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Ambient temperature during storage | -60…80 °C |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Flame retardancy | V1 corresponds to UL 94 |
| Mechanical robustness | Vibrations relay open: 2 Gn, 5 - 300 Hz; Vibrations relay closed: 4 Gn, 5 - 300 Hz; Shocks relay closed: 15 Gn for 11 ms; Shocks relay open: 8 Gn for 11 ms |
| Height | 85 mm |
| Width | 90 mm |
| Depth | 92 mm |
| Product weight | 0,797 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 10,9 cm |
| VPE 1 width | 11,4 cm |
| VPE 1 length | 11,8 cm |
| Packaging weight (Lbs) | 815,0 g |
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international standards. The power sizes 40 to 65 A are equipped with EverLink terminals. These are patented and ensure a reliable and permanent connection.