Schneider Electric LC2D25B7V, EAN: 3389110412550

Schneider Electric LC2D25B7V contactor 3p 24V

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2D25B7V contactor 3p 24V

Lieske Part No. 500037
Mfg Part No LC2D25B7V
EAN-Code 3389110412550
Manufacturer Schneider Electric
Here only 289,18 EUR
344,12 EUR incl. VAT

Further information for Schneider Electric LC2D25B7V contactor 3p 24V

Complementary
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandconforming to IACS E10; conforming to IEC 60947-1 Annex Q category D
Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C; 60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor closed: 15 Gn for 11 ms; Shocks contactor open: 8 Gn for 11 ms
Height85 mm
Width90 mm
Depth92 mm
Net weight0.787 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys Deca; TeSys Deca
Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-1; AC-3
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current25 A (at
Motor power kW5.5 kW at 220...230 V AC 50 Hz; 11 kW at 380...400 V AC 50 Hz; 11 kW at 415...440 V AC 50 Hz; 15 kW at 500 V AC 50 Hz; 15 kW at 660...690 V AC 50 Hz
Motor power hp3 hp at 230/240 V AC 60 Hz for 1 phase motors; 5 hp at 200/208 V AC 60 Hz for 3 phases motors; 2 hp at 115 V AC 60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 60 Hz for 3 phases motors; 15 hp at 460/480 V AC 60 Hz for 3 phases motors; 20 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage24 V AC 50/60 Hz
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 40 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current50 A 40 °C - 10 min for power circuit; 120 A 40 °C - 1 min for power circuit; 240 A 40 °C - 10 s for power circuit; 380 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at
Average impedance2 mOhm - Ith 40 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Electrical durability1.65 Mcycles 25 A AC-3 at Ue
Power dissipation per pole1.25 W AC-3; 3.2 W AC-1
Front coverWith
Interlocking typeElectrical and mechanical
Mounting supportRail; Plate
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1
Product certificationsDNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA; CB
Operating time12...22 ms closing; 4...19 ms opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Maximum operating rate3600 cyc/h 60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.500 cm
Package 1 Width11.500 cm
Package 1 Length14.100 cm
Package 1 Weight954.000 g
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international standards. The power sizes 40 to 65 A are equipped with EverLink terminals. These are patented and ensure a reliable and permanent connection.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/500037
qrcode für Schneider Electric LC2D25B7V contactor 3p 24V