| Additional features |
| Coil technology | Without integrated switching module |
| Control circuit voltage limits | 0.3 - 0.6 Uc (-40…70 °C): drop-out voltage AC 50/60 Hz; 0.8 - 1.1 Uc (-40…60 °C): operation AC 50 Hz; 0.85 - 1.1 Uc (-40…60 °C): operation AC 60 Hz; 1 - 1.1 Uc (60…70 °C): operation AC 50/60 Hz |
| Input power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat emission | 2…3 W at 50/60 Hz |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Insulation resistance | > 10 MΩ for signal circuits |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys; TeSys Deca |
| Product name | TeSys D; TeSys Deca |
| Product or component type | Reversing safety |
| Device short name | LC2D |
| Application of contactor | Resistive load; motor control |
| Application category | AC-1; AC-3; AC-3e |
| Device representation | Pre-fabricated with reversing power busbar |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 18 A (at |
| Motor power (kW) | 4 kW at 220 - 230 V AC 50 - 60 Hz; 7.5 kW at 380 - 400 V AC 50 - 60 Hz; 9 kW at 415 V AC 50 - 60 Hz; 9 kW at 440 V AC 50 - 60 Hz; 10 kW at 500 V AC 50 - 60 Hz; 10 kW at 660 - 690 V AC 50 - 60 Hz |
| Motor power HP (UL / CSA) | 1 hp at 115 V AC 60 Hz for 1-phase motors; 3 hp at 230/240 V AC 60 Hz for 1-phase motors; 5 hp at 200/208 V AC 60 Hz for 3-phase motors; 5 hp at 230/240 V AC 60 Hz for 3-phase motors; 10 hp at 460/480 V AC 60 Hz for 3-phase motors; 15 hp at 575/600 V AC 60 Hz for 3-phase motors |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 400 V AC 50/60 Hz |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947 |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for signal circuit; 32 A (at 60 °C) for power circuit |
| [Irms] Rated making capacity | 140 A AC for signal circuit conforming to IEC 60947-5-1; 250 A DC for signal circuit conforming to IEC 60947-5-1; 300 A at 440 V for circuit conforming to IEC 60947 |
| Rated breaking capacity | 300 A at 440 V for circuit, corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 40 A 40 °C - 10 min for circuit; 84 A 40 °C - 1 min for circuit; 145 A 40 °C - 10 s for circuit; 240 A 40 °C - 1 s for circuit; 100 A - 1 s for signal circuit; 120 A - 500 ms for signal circuit; 140 A - 100 ms for signal circuit |
| Associated fuse | 10 A gG for signal circuits, complying with IEC 60947-5-1; 50 A gG at |
| Average impedance | 2.5 MOhm - Ith 32 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 690 V compliant with IEC 60947-4-1; Circuit: 600 V CSA certified; Circuit: 600 V UL certified; Signal circuit: 690 V compliant with IEC 60947-1; Signal circuit: 600 V CSA certified; Signal circuit: 600 V UL certified |
| Electrical lifetime | 1.65 Mcycles 18 A AC-3 at Ue |
| Power dissipation per pole | 0,8 W AC-3; 2,5 W AC-1; 0,8 W AC-3e |
| Front cover | With |
| Locking type | Mechanical |
| Mounting bracket | Plate; rail |
| Standards | CSA C22.2 No. 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1 |
| Product certifications | DNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA |
| Tightening moment | Circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with screwdriver position No. 2; Circuit: 2.5 Nm - on screw terminals - with screwdriver position No. 2 |
| Operating time | 12 - 22 ms closing; 4 - 19 ms opening |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 15 Mcycles |
| Max. operating rate | 3600 cyc/h 60 °C |
| Mounting |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Climate resistance | Complies with IACS E10; complies with IEC 60947-1 Annex Q Category D |
| Coating | TH corresponds to IEC 60068-2-30 |
| Pollution degree | 3 |
| Operating ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Ambient temperature during storage | -60…80 °C |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Flame retardancy | V1 corresponds to UL 94 |
| Mechanical robustness | Vibrations contactor open: 2 Gn, 5 - 300 Hz; Vibrations contactor closed: 4 Gn, 5 - 300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms |
| Height | 77 mm |
| Width | 90 mm |
| Depth | 86 mm |
| Product weight | 0,707 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 9,500 cm |
| VPE 1 width | 11,300 cm |
| VPE 1 length | 14,000 cm |
| Packaging weight (Lbs) | 794,000 g |
| VPE 2 type | S02 |
| VPE 2 quantity | 6 |
| VPE 2 height | 15,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 5,084 kg |
| VPE 3 type | P12 |
| VPE 3 quantity | 96 |
| VPE 3 height | 45,000 cm |
| VPE 3 width | 80,000 cm |
| VPE 3 length | 120,000 cm |
| VPE 3 weight | 93,344 kg |
3-pole TeSys D reversing contactor for motor applications up to 7.5kW@400V. It offers 400 V 50/60 Hz AC coils, integrated auxiliary contacts 2NO+2NC (NC mirror contacts), power and control connections via screw terminals. Equipped with pre-wired power connections with 2 rotation directions and mechanical interlock. Compact (90 mm wide), DIN rail mounted, it ensures high reliability and durability. It has multiple standards (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliance (RoHs/Reach).