Schneider Electric LC2D18BDV, EAN: 3389110414028

Schneider Electric LC2D18BDV contactor 3p 1S1Ö

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2D18BDV contactor 3p 1S1Ö

Lieske Part No. 498668
Mfg Part No LC2D18BDV
EAN-Code 3389110414028
Manufacturer Schneider Electric
Here only 346,69 EUR
412,56 EUR incl. VAT

Further information for Schneider Electric LC2D18BDV contactor 3p 1S1Ö

Complementary
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
Time constant28 ms
Inrush power in W5.4 W (at 20 °C)
Hold-in power consumption in W5.4 W at 20 °C
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandconforming to IACS E10; conforming to IEC 60947-1 Annex Q category D
Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C; 60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms
Height77 mm
Width90 mm
Depth95 mm
Net weight1.037 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys D; TeSys Deca
Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-3; AC-1; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current18 A (at
Motor power kW4 kW at 220...230 V AC 50...60 Hz; 7.5 kW at 380...400 V AC 50...60 Hz; 9 kW at 415 V AC 50...60 Hz; 9 kW at 440 V AC 50...60 Hz; 10 kW at 500 V AC 50...60 Hz; 10 kW at 660...690 V AC 50...60 Hz
Motor power hp1 hp at 115 V AC 60 Hz for 1 phase motors; 3 hp at 230/240 V AC 60 Hz for 1 phase motors; 5 hp at 200/208 V AC 60 Hz for 3 phases motors; 5 hp at 230/240 V AC 60 Hz for 3 phases motors; 10 hp at 460/480 V AC 60 Hz for 3 phases motors; 15 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit typeDC standard
[Uc] control circuit voltage24 V DC
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 32 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current40 A 40 °C - 10 min for power circuit; 84 A 40 °C - 1 min for power circuit; 145 A 40 °C - 10 s for power circuit; 240 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at
Average impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Electrical durability1.65 Mcycles 18 A AC-3 at Ue
Power dissipation per pole0.8 W AC-3; 2.5 W AC-1; 0.8 W AC-3e
Front coverWith
Interlocking typeElectrical and mechanical
Mounting supportRail; Plate
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1
Product certificationsDNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA
Operating time53.55...72.45 ms closing; 16...24 ms opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability30 Mcycles
Maximum operating rate3600 cyc/h 60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.600 cm
Package 1 Width11.700 cm
Package 1 Length14.200 cm
Package 1 Weight1.128 kg
3-pole TeSys D reversing contactor for motor applications up to 7.5kW@400V. It features 24 V DC coils, 2 NO + 2 NC integrated auxiliary contacts (NC mirror contacts), power and control connections via screw terminals. Equipped with pre-wired power connections with reversing function, mechanical interlock and electrical interlock. Compact (90 mm wide), DIN rail mounted, it ensures high reliability and durability. It has multiple standards (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliance (RoHs/Reach).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/498668
qrcode für Schneider Electric LC2D18BDV contactor 3p 1S1Ö