| Additional features |
| Coil technology | Integrated bidirectional transient voltage suppressor diodes |
| Control circuit voltage limits | 0.1 - 0.25 Uc (-40…70 °C): drop voltage DC; 0.7 - 1.25 Uc (-40…60 °C): operation DC; 1 - 1.25 Uc (60…70 °C): operation DC |
| Time constant | 28 ms |
| Absorption power in W | 5.4 W (at 20 °C) |
| Holding power consumption in W | 5.4 W at 20 °C |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Insulation resistance | > 10 MΩ for signal circuits |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys; TeSys Deca |
| Product name | TeSys D; TeSys Deca |
| Product or component type | Reversing safety |
| Device short name | LC2D |
| Application of contactor | Motor control; resistive load |
| Application category | AC-3; AC-1 |
| Device representation | Pre-fabricated with reversing power busbar |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 25 A (at |
| Motor power (kW) | 3 kW at 220 - 230 V AC 50 Hz; 5.5 kW at 380 - 400 V AC 50 Hz; 5.5 kW at 415 - 440 V AC 50 Hz; 7.5 kW at 500 V AC 50 Hz; 7.5 kW at 660 - 690 V AC 50 Hz |
| Motor power HP (UL / CSA) | 1 hp at 115 V AC 60 Hz for 1-phase motors; 2 hp at 230/240 V AC 60 Hz for 1-phase motors; 3 hp at 200/208 V AC 60 Hz for 3-phase motors; 3 hp at 230/240 V AC 60 Hz for 3-phase motors; 7.5 hp at 460/480 V AC 60 Hz for 3-phase motors; 10 hp at 575/600 V AC 60 Hz for 3-phase motors |
| Control circuit type | DC Standard |
| [Uc] control circuit voltage | 24 V DC |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947 |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for signal circuit; 25 A (at 60 °C) for power circuit |
| [Irms] Rated making capacity | 250 A at 440 V for circuits conforming to IEC 60947; 140 A AC for signal circuits conforming to IEC 60947-5-1; 250 A DC for signal circuits conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for circuit, conforms to IEC 60947 |
| [Icw] rated short-time current withstand | 30 A 40 °C - 10 min for circuit; 61 A 40 °C - 1 min for circuit; 105 A 40 °C - 10 s for circuit; 210 A 40 °C - 1 s for circuit; 100 A - 1 s for signal circuit; 120 A - 500 ms for signal circuit; 140 A - 100 ms for signal circuit |
| Associated fuse | 10 A gG for signal circuits, complies with IEC 60947-5-1; 40 A gG at |
| Average impedance | 2.5 MOhm - Ith 25 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 690 V compliant with IEC 60947-4-1; Circuit: 600 V CSA certified; Circuit: 600 V UL certified; Signal circuit: 690 V compliant with IEC 60947-1; Signal circuit: 600 V CSA certified; Signal circuit: 600 V UL certified |
| Electrical lifetime | 2 Mcycles 12 A AC-3 at Ue |
| Power dissipation per pole | 1,56 W AC-1; 0,36 W AC-3 |
| Front cover | With |
| Locking type | Electrical and mechanical |
| Mounting bracket | Plate; rail |
| Standards | CSA C22.2 No. 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1 |
| Product certifications | DNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA |
| Tightening moment | Circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with screwdriver position No. 2; Circuit: 2.5 Nm - on screw terminals - with screwdriver position No. 2 |
| Operating time | 53.55 - 72.45 ms closing; 16 - 24 ms opening |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 30 Mcycles |
| Max. operating rate | 3600 cyc/h 60 °C |
| Mounting |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Climate resistance | Complies with IACS E10; complies with IEC 60947-1 Annex Q Category D |
| Coating | TH corresponds to IEC 60068-2-30 |
| Pollution degree | 3 |
| Operating ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Ambient temperature during storage | -60…80 °C |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Flame retardancy | V1 corresponds to UL 94 |
| Mechanical robustness | Vibrations contactor open: 2 Gn, 5 - 300 Hz; Vibrations contactor closed: 4 Gn, 5 - 300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms |
| Height | 77 mm |
| Width | 90 mm |
| Depth | 95 mm |
| Product weight | 1,027 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 13,800 cm |
| VPE 1 width | 9,300 cm |
| VPE 1 length | 11,300 cm |
| Packaging weight (Lbs) | 1,146 kg |
| VPE 2 type | S02 |
| VPE 2 quantity | 6 |
| VPE 2 height | 15,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 7,115 kg |
3-pole TeSys D reversing contactor for motor applications up to 5.5kW@400V.5.5kW@400VkW@400V. It features 24 V DC coils, 2 NO + 2 NC integrated auxiliary contacts (NC mirror contacts), power and control connections via screw terminals. Equipped with pre-wired power connections with reversing function, mechanical interlock and electrical interlock. Compact (90 mm wide), DIN rail mounted, it ensures high reliability and durability. It has multiple standards (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliance (RoHs/Reach).