Schneider Electric LC2D115F7, EAN: 3389110531183

Schneider Electric LC2D115F7 contactor 3p 115A 110V

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2D115F7 contactor 3p 115A 110V

Lieske Part No. 585742
Mfg Part No LC2D115F7
EAN-Code 3389110531183
Manufacturer Schneider Electric
Here only 1.838,36 EUR
2.187,65 EUR incl. VAT

Further information for Schneider Electric LC2D115F7 contactor 3p 115A 110V

Complementary
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.3...0.5 Uc (55 °C):drop-out AC 50/60 Hz; 0.8...1.15 Uc (55 °C):operational AC 50/60 Hz
Inrush power in VA280…350 VA 60 Hz cos phi 0.8 (at 20 °C) ; 280…350 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA2…18 VA (at 20 °C) cos phi 0.3 60 Hz; 2…18 VA (at 20 °C) cos phi 0.3 50 Hz
Heat dissipation3…8 W at 50/60 Hz
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandconforming to IACS E10
Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C; 60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor closed: 15 Gn for 11 ms; Shocks contactor open: 6 Gn for 11 ms
Height158 mm
Width266 mm
Depth148 mm
Net weight6.35 kg
Logistical informations
Country of originCZ
Main
RangeTeSys
Product nameTeSys Deca
Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-1; AC-3; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current200 A (at
Motor power kW30 kW at 220...230 V AC 50...60 Hz; 55 kW at 380...400 V AC 50...60 Hz; 59 kW at 415 V AC 50...60 Hz; 59 kW at 440 V AC 50...60 Hz; 75 kW at 500 V AC 50...60 Hz; 80 kW at 660...690 V AC 50...60 Hz; 65 kW at 1000 V AC 50...60 Hz
Motor power hp30 hp at 200/208 V AC 60 Hz for 3 phases motors; 40 hp at 230/240 V AC 60 Hz for 3 phases motors; 75 hp at 460/480 V AC 60 Hz for 3 phases motors; 100 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current200 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current250 A 40 °C - 10 min for power circuit; 550 A 40 °C - 1 min for power circuit; 950 A 40 °C - 10 s for power circuit; 1100 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 250 A gG at
Average impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1
Electrical durability0.8 Mcycles 200 A AC-1 at Ue
Power dissipation per pole24 W AC-1; 7.9 W AC-3; 7.9 W AC-3e
Front coverWith
Interlocking typeElectrical; Mechanical
Mounting supportRail; Plate
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508
Product certificationsBV; CCC; CSA; DNV; GL; RINA; UL; EAC; UKCA
Tightening torqueControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Operating time20...50 ms closing; 6...20 ms opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
Maximum operating rate2400 cyc/h 60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height23.000 cm
Package 1 Width31.500 cm
Package 1 Length37.000 cm
Package 1 Weight6.500 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height75.000 cm
Package 2 Width80.000 cm
Package 2 Length60.000 cm
Package 2 Weight60.000 kg
3-pole reversing contactor TeSys D for motor applications. With 115A AC-3 55kW@400V, it includes a 110V 50/60Hz AC coil, 2NC+2NO auxiliary contacts, mechanical and electrical interlock.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/585742
qrcode für Schneider Electric LC2D115F7 contactor 3p 115A 110V