Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
Time constant28 ms
Inrush power in W5.4 W (at 20 °C)
Hold-in power consumption in W5.4 W at 20 °C
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandconforming to IACS E10; conforming to IEC 60947-1 Annex Q category D
Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C; 60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms
Height77 mm
Width90 mm
Depth95 mm
Net weight1.017 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys D; TeSys Deca
Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-1; AC-3; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current9 A (at
Motor power kW2.2 kW at 220...230 V AC 50...60 Hz; 4 kW at 380...400 V AC 50...60 Hz; 4 kW at 415 V AC 50...60 Hz; 4 kW at 440 V AC 50...60 Hz; 5.5 kW at 500 V AC 50...60 Hz; 5.5 kW at 660...690 V AC 50...60 Hz
Motor power hp0.5 hp at 115 V AC 60 Hz for 1 phase motors; 1 hp at 230/240 V AC 60 Hz for 1 phase motors; 2 hp at 200/208 V AC 60 Hz for 3 phases motors; 2 hp at 230/240 V AC 60 Hz for 3 phases motors; 5 hp at 460/480 V AC 60 Hz for 3 phases motors; 7.5 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit typeDC standard
[Uc] control circuit voltage48 V DC
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 25 A (at 60 °C) for power circuit
Irms rated making capacity250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at
Average impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Electrical durability0.6 Mcycles 25 A AC-1 at Ue
Power dissipation per pole0.2 W AC-3; 1.56 W AC-1; 0.2 W AC-3e
Front coverWith
Interlocking typeMechanical
Mounting supportPlate; Rail
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1
Product certificationsDNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA
Operating time53.55...72.45 ms closing; 16...24 ms opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability30 Mcycles
Maximum operating rate3600 cyc/h 60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.400 cm
Package 1 Width11.400 cm
Package 1 Length11.000 cm
Package 1 Weight1.080 kg
Unit Type of Package 2S03
Number of Units in Package 216
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight17.700 kg
Unit Type of Package 3P06
Number of Units in Package 3128
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight149.600 kg
3-pole reversing contactor TeSys D for motor applications. Rated 9A AC-3 4kW@400V, includes a 48V DC coil, 2 NC+2 NO auxiliary contacts, a mechanical interlock.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/499284
qrcode für Schneider Electric LC2D09ED contactor 3p 1S1Ö