Schneider Electric LC2D096BD, EAN: 3389110706529

Schneider Electric LC2D096BD contactor 3p 1S1Ö 24VDC

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC2D096BD contactor 3p 1S1Ö 24VDC

Lieske Part No. 763922
Mfg Part No LC2D096BD
EAN-Code 3389110706529
Manufacturer Schneider Electric
Here only 301,60 EUR
358,90 EUR incl. VAT

Further information for Schneider Electric LC2D096BD contactor 3p 1S1Ö 24VDC

Complementary
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
Time constant28 ms
Inrush power in W5.4 W (at 20 °C)
Hold-in power consumption in W5.4 W at 20 °C
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance> 10 MOhm for signalling circuit
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandconforming to IACS E10; conforming to IEC 60947-1 Annex Q category D
Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C; 60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms
Height77 mm
Width90 mm
Depth95 mm
Net weight1.017 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys D; TeSys Deca
Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-1; AC-3; AC-3e
Device presentationPreassembled with reversing power busbar
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current9 A (at
Motor power kW2.2 kW at 220...230 V AC 50...60 Hz; 4 kW at 380...400 V AC 50...60 Hz; 4 kW at 415 V AC 50...60 Hz; 4 kW at 440 V AC 50...60 Hz; 5.5 kW at 500 V AC 50...60 Hz; 5.5 kW at 660...690 V AC 50...60 Hz
Motor power hp0.5 hp at 115 V AC 60 Hz for 1 phase motors; 1 hp at 230/240 V AC 60 Hz for 1 phase motors; 2 hp at 200/208 V AC 60 Hz for 3 phases motors; 2 hp at 230/240 V AC 60 Hz for 3 phases motors; 5 hp at 460/480 V AC 60 Hz for 3 phases motors; 7.5 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit typeDC standard
[Uc] control circuit voltage24 V DC
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 25 A (at 60 °C) for power circuit
Irms rated making capacity250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at
Average impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Electrical durability0.6 Mcycles 25 A AC-1 at Ue
Power dissipation per pole0.2 W AC-3; 1.56 W AC-1; 0.2 W AC-3e
Front coverWith
Interlocking typeMechanical
Mounting supportRail; Plate
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1
Product certificationsDNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA
Connections - terminalsControl circuit: lugs-ring terminals (external diameter: 8 mm) ; Power circuit: lugs-ring terminals (external diameter: 8 mm)
Operating time53.55...72.45 ms closing; 16...24 ms opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability30 Mcycles
Maximum operating rate3600 cyc/h 60 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.4 cm
Package 1 Width11.4 cm
Package 1 Length11.0 cm
Package 1 Weight1.08 kg
3-pole reversing contactor TeSys D for motor applications up to 4kW@400V. It offers a 24V DC coil, built-in auxiliary contacts 2NC+2NO with NO certified mirror, mechanical interlock and ring plug connections. Compact, DIN rail mounting ensuring reliability and durability. It is certified according to several standards (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/763922
qrcode für Schneider Electric LC2D096BD contactor 3p 1S1Ö 24VDC