| Complementary |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| [Ith] conventional free air thermal current | 20 A (at 55 °C) for power circuit |
| Irms rated making capacity | 50 A AC conforming to NF C 63-110; 50 A AC conforming to IEC 60947 |
| Rated breaking capacity | 40 A at |
| [Icw] rated short-time withstand current | 40 A 55 °C for power circuit |
| Associated fuse rating | 20 A gI at |
| Average impedance | 4 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to BS 5424; Power circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to UL 508; Power circuit: 690 V conforming to VDE 0110 group C; Power circuit: 690 V conforming to CSA C22.2 No 14 |
| Mounting support | Rail |
| Standards | EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1 |
| Product certifications | CB Scheme; CE; UKCA; EAC; cULus |
| Connections - terminals | Connector 1 cable(s) 1.5…6 mm²solid; Connector 2 cable(s) 1.5…4 mm²solid; Connector 1 cable(s) 0.5…6 mm²flexible without cable end; Connector 2 cable(s) 0.35…2.5 mm²flexible without cable end; Connector 1 cable(s) 0.35…6 mm²flexible with cable end; Connector 2 cable(s) 0.35…1.5 mm²flexible with cable end |
| Tightening torque | Power circuit: 0.8 N.m - on connector - with screwdriver pozidriv No 1 |
| Operating time | 6...8 ms coil de-energisation and NO opening; 7...14 ms coil energisation and NO closing |
| Mechanical durability | 10 Mcycles |
| Maximum operating rate | 1200 cyc/h |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at |
| Inrush power in VA | 16 VA 50/60 Hz (at 20 °C) |
| Hold-in power consumption in VA | 4.2 VA 50/60 Hz (at 20 °C) |
| Heat dissipation | 1.4 W at 50/60 Hz |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP2X conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50015 |
| Ambient air temperature for operation | -20…50 °C |
| Ambient air temperature for storage | -50…70 °C |
| Operating altitude | 2000 m without derating |
| Height | 56 mm |
| Width | 27 mm |
| Depth | 55.5 mm |
| Net weight | 0.132 kg |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Product name | TeSys SK |
| Product or component type | Mini contactor |
| Device short name | LC1SKGC |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-1 |
| power pole contact composition | 2P |
| Pole contact composition | 2 NO |
| [Ie] rated operational current | 5 A at |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.0 cm |
| Package 1 Width | 6.0 cm |
| Package 1 Length | 6.5 cm |
| Package 1 Weight | 116.0 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 15.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 4.954 kg |
The mini contactor LC1SKGC200B7 from the TeSys series by Schneider Electric is a compact control device for actuating resistive loads and motors in industrial, infrastructure, and building applications. It features a 2-pole contact configuration with two normally open contacts and is designed for use in electrical circuits with a rated operating voltage of 690 V AC. Control is achieved via a coil with a rated control circuit voltage of 24 V AC at 50/60 Hz, enabling easy integration into existing control systems. The device is designed for usage categories AC-3 and AC-1, with category AC-3 being relevant for motor control. The rated operating current is 5 A at 400 V AC-3, while the conventional thermal current in free air at 55 °C is specified as 20 A. The mechanical life expectancy is 10 million switching cycles, and the maximum operating rate is 1200 switching operations per hour.
Applications
This contactor is suitable for simple machine control in industrial, infrastructure, and building applications. It is commonly used in systems requiring a reliable and compact switching solution for small to medium power levels, such as conveyor systems, pump control, or lighting installations. The compact design with dimensions of 27 mm (width) × 56 mm (height) × 55.5 mm (depth) allows space-saving mounting on a rail, making it particularly suitable for limited enclosure spaces.
Functions and Features in Detail
The device includes two normally open contacts (2 S), which close the circuit when the coil is energized. The operating time is 6–8 ms for coil de-energization and NO opening, and 7–14 ms for coil energization and NO closing. The pickup power is 16 VA, and the holding power consumption is 4.2 VA at 50/60 Hz and 20 °C. The heat dissipation is 1.4 W. The terminals are designed as plugs, enabling connection with cables of cross-section 1.5 to 6 mm² (rigid) or 0.35 to 6 mm² (flexible with cable end) at terminals 1 and 2. The pickup torque is 0.8 Nm, with mounting performed using a screwdriver in position No. 1.
Technology Explained Simply
The contactor operates on the electromagnetic principle: when the control voltage (24 V AC) is applied, the coil is energized, generating a magnetic field that pulls the armature and closes the contacts. When the voltage is switched off, the armature returns by spring force, opening the contacts again. The rated insulation voltage is 690 V and complies with international standards such as IEC 60947, UL 508, VDE 0110, and CSA C22.2 No. 14. The protection class IP2x according to VDE 0106 protects against finger contact but is not suitable for outdoor use or humid environments. The operating temperature range is -20 °C to 50 °C, with storage temperature ranging from -50 °C to 70 °C. The operating altitude is up to 2000 m without performance reduction.
Compatibility and Accessories
The contactor is compatible with various overvoltage limiters that serve to protect the coil. These include the varistor LA4SKE1E, the diode LA4SKC1U for 24–250 V DC, and the overvoltage limiter LA4SKE1U for 110–250 V AC/DC. These accessories can be used to extend the service life and reduce disturbances in the control circuit. The associated fuse rating is 20 A gI, enabling selection of the appropriate fuse for the circuit.
Mounting and Installation
Mounting is performed on a rail, with the device dimensions (27 mm width, 56 mm height, 55.5 mm depth) allowing easy placement in standard enclosures. The terminals are designed for various cable cross-sections, with connections made using a screwdriver in position No. 1. Installation is carried out in environments with ambient temperatures from -20 to 50 °C and operating altitudes up to 2000 m. The IP2x protection class prevents contact but requires additional protective measures in humid or dusty environments.
Operational Advantages
The mini contactor offers high operational reliability with a long mechanical life of 10 million switching cycles and a maximum operating rate of 1200 operations per hour. The simple interface allows direct control by electronic control devices such as PLCs. Certifications according to CB regulation, CE, UKCA, EAC, and cULus, along with compliance with standards such as EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1, ensure adherence to international safety and quality standards. The compact design and rail mounting facilitate installation and maintenance in industrial systems.
Standards and Regulations
The device complies with standards EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Product standards include NF C 63-110, IEC 60947, BS 5424, VDE 0660, and VDE 0110 Group C. Certifications include CB regulation, CE, UKCA, EAC, and cULus, enabling use in various regions worldwide. The rated insulation voltage of 690 V conforms to international standards such as IEC 60947, UL 508, VDE 0110, and CSA C22.2 No. 14.
Product Certifications
Certifications include CB regulation, CE, UKCA, EAC, and cULus, confirming compliance with international safety and quality requirements. Conformity with standards EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1 ensures suitability for various markets. Product standards include NF C 63-110, IEC 60947, BS 5424, VDE 0660, and VDE 0110 Group C.