Schneider Electric LC1K1610B5, EAN: 3606489602154

Schneider Electric LC1K1610B5 contactor 3P 16A 24VAC

Schneider Electric LC1K1610B5 contactor 3P 16A 24VAC

Lieske Part No. 1017130
Mfg Part No LC1K1610B5
EAN-Code 3606489602154
Manufacturer Schneider Electric
Here only 44,34 EUR
52,76 EUR incl. VAT

Further information for Schneider Electric LC1K1610B5 contactor 3P 16A 24VAC

Additional features
Application categoryAC-3; AC-3e
Pole description3P
Pole contact composition3 S
[Ue] Rated operational voltageCircuit:
[Ie] rated operational current16 A (at
Control circuit typeAC at 50 Hz
[Uc] control circuit voltage24 V AC 50 Hz
Motor power (kW)4 kW at 220 - 230 V AC 50/60 Hz AC-3; 7.5 kW at 380 - 415 V AC 50/60 Hz AC-3; 5.5 kW at 440 V AC 50/60 Hz AC-3; 4 kW at 690 V AC 50/60 Hz AC-3; 4 kW at 220 - 230 V AC 50/60 Hz AC-3e; 7.5 kW at 380 - 415 V AC 50/60 Hz AC-3e; 5.5 kW at 440 V AC 50/60 Hz AC-3e; 4 kW at 690 V AC 50/60 Hz AC-3e
Configuration of auxiliary contacts1 S
[Uimp] Rated impulse voltage withstand8 kV
Over voltage categoryIII
[Ith] conventional thermal current in free air20 A (at 60 °C) for circuit; 10 A (at 50 °C) for signal circuit
[Irms] Rated making capacity160 A AC for circuit conforming to IEC 60947; 110 A AC for signal circuit conforming to IEC 60947
Rated breaking capacity110 A at 440 V corresponds to IEC 60947; 80 A at 500 V corresponds to IEC 60947; 70 A at 660 - 690 V corresponds to IEC 60947
[Icw] rated short-time current withstand115 A at 50 °C - 1 s for circuit; 105 A at 50 °C - 5 s for circuit; 100 A at 50 °C - 10 s for circuit; 75 A at 50 °C - 30 s for circuit; 55 A at 50 °C - 1 min for circuit; 50 A at 50 °C - 3 min for circuit; 25 A at 50 °C - >= 15 min for circuit; 80 A - 1 s for signal circuit; 90 A - 500 ms for signal circuit; 110 A - 100 ms for signal circuit
Associated fuse25 A gG at
Average impedance3 MOhm - Ith 20 A 50 Hz for circuit
[Ui] Rated insulation voltageCircuit: 690 V complies with IEC 60947-4-1; Circuit: 600 V complies with UL 60947-4-1; Circuit: 600 V complies with CSA C22.2 No. 60947-4-1; Signal circuit: 690 V complies with IEC 60947-4-1; Signal circuit: 600 V complies with UL 60947-4-1; Signal circuit: 600 V complies with CSA C22.2 No. 60947-4-1
Insulation resistance> 10 MΩ for signal circuits
Input power in VA30 VA (at 20 °C)
Hold power consumption in VA4.5 VA (at 20 °C)
Heat emission1,3 W
Control circuit voltage limitsOperation: 0.8 - 1.15 Uc (at = 0.20 Uc (at
Connections - terminalsScrew terminals 1 cable(s) 1.5…4 mm² solid; screw terminals 1 cable(s) 0.75…4 mm² stranded without ferrule; screw terminals 1 cable(s) 0.34…2.5 mm² stranded with ferrule; screw terminals 2 cable(s) 1.5…4 mm² solid; screw terminals 2 cable(s) 0.75…4 mm² stranded without ferrule; screw terminals 2 cable(s) 0.34…1.5 mm² stranded with ferrule
Max. operating rate3600 cyc/h
Coil technologyWithout integrated switching module
Type of auxiliary contactsType instantaneous 1 S
Min. switching current5 mA for signal circuit
Min. switching voltage17 V for signal circuit
Mounting bracketPlate; rail
Tightening moment0.8…1.3 Nm - on screw terminals Phillips No. 2; 0.8…1.3 Nm - on screw terminals flat Ø 6; 0.8…1.3 Nm - on screw terminals position No. 2
Operating time10 - 20 ms coil de-energisation and NO opening; 10 - 20 ms coil energisation and NO closing
Security level ratingB10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1
Non-overlapping distance0,5 mm
Mechanical life10 Mcycles
Electrical lifetime1.3 Mcycles 16 A AC-3 at Ue
Height58 mm
Width45 mm
Depth57 mm
Product weight0,18 kg
Contractual warranty
Warranty (in months)18
Main features
Product seriesTeSys
Product or component typeContactor
Device short nameLC1K
Device applicationControl
Application of contactorMotor control
Mounting
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No. 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsCB certification; CCC; UL; CSA; EAC; CE; UKCA
Degree of protection (IP)IP2x corresponds to VDE 0106
CoatingTC corresponds to IEC 60068; TC corresponds to DIN 50016
Operating ambient temperature-25…50 °C
Ambient temperature during storage-50…80 °C
Operating altitude2,000 m without derating
Flame retardancyV1 corresponds to UL 94
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height4,500 cm
VPE 1 width6,000 cm
VPE 1 length6,500 cm
Packaging weight (Lbs)180,300 g
VPE 2 typeS02
VPE 2 quantity50
VPE 2 height15,000 cm
VPE 2 width30,000 cm
VPE 2 length40,000 cm
VPE 2 weight9,274 kg
VPE 3 typeP06
VPE 3 quantity800
VPE 3 height75,000 cm
VPE 3 width80,000 cm
VPE 3 length60,000 cm
VPE 3 weight156,376 kg
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1017130
qrcode für Schneider Electric LC1K1610B5 contactor 3P 16A 24VAC