| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 12 A (at |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| Motor power kW | 3 kW at 220...230 V AC 50/60 Hz AC-3; 5.5 kW at 380...415 V AC 50/60 Hz AC-3; 5.5 kW at 440 V AC 50/60 Hz AC-3; 4 kW at 690 V AC 50/60 Hz AC-3; 3 kW at 220...230 V AC 50/60 Hz AC-3e; 5.5 kW at 380...415 V AC 50/60 Hz AC-3e; 5.5 kW at 440 V AC 50/60 Hz AC-3e; 4 kW at 690 V AC 50/60 Hz AC-3e; 3 kW at 220...230 V AC 50/60 Hz AC-4; 5.5 kW at 380...415 V AC 50/60 Hz AC-4; 5.5 kW at 440 V AC 50/60 Hz AC-4; 4 kW at 690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 144 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 115 A 50 °C - 1 s for power circuit; 105 A 50 °C - 5 s for power circuit; 100 A 50 °C - 10 s for power circuit; 75 A 50 °C - 30 s for power circuit; 55 A 50 °C - 1 min for power circuit; 50 A 50 °C - 3 min for power circuit; 25 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.20 Uc (at |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Auxiliary contacts type | type instantaneous 1 NO |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting support | Plate; Rail |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 12 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.18 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| Contactor application | Motor control; Resistive load |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.600 cm |
| Package 1 Width | 6.200 cm |
| Package 1 Length | 4.800 cm |
| Package 1 Weight | 177.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 50 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.204 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 400 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 83.340 kg |
The LC1K1210B7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electric drives and resistive loads. It is particularly used for motor control in industrial, infrastructure, and building applications where reliable and simple machine control is required. The device has a rated operational current of 12 A at an operating voltage of 400 V AC in usage category AC-3, corresponding to a motor power of 5.5 kW. The coil is designed for a control circuit voltage of 24 V AC at 50/60 Hz, enabling easy integration into existing control systems. The interface is easy to operate and allows direct connection to electronic control devices such as PLC systems.
Applications
This contactor is suitable for applications in industrial automation, building and infrastructure technology, and machine construction. It is used to safely and reliably switch on and off electric motors, especially in systems requiring high operational rates. Usage categories AC-1, AC-3, AC-3e, and AC-4 cover various load types, from purely resistive loads to motors with high inrush currents. The combination of robust design and high operational rate makes it suitable for continuously operated systems.
Functions and Equipment in Detail
The device features a main contact configuration of 3 normally open contacts (3 S) for the main current circuit and an additional auxiliary contact in the form of a normally open contact (1 S). This auxiliary contact enables integration into control circuits, for example for feedback or interlocking switching operations. The auxiliary contacts are instantaneous and can be used for signals in control systems. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA in the signal circuit, ensuring reliable switching function even at low loads.
Technology Explained Simply
The contactor coil is supplied with 24 V AC and requires a power of 30 VA at pull-in, while the holding power consumption is 4.5 VA. The heat dissipation is 1.3 W, indicating low thermal load on the surrounding environment. The rated impulse voltage withstand is 8 kV, and the overvoltage category is III, ensuring high safety against transient voltage surges. The rated insulation voltage is 690 V for both the current circuit and the signal circuit according to IEC 60947-4-1, ensuring safe insulation even at high voltages. The insulation resistance is over 10 MΩ for the signal circuit, sufficiently high to minimize interference.
Compatibility and Accessories
The contactor is compatible with various auxiliary switch blocks that extend control functions. These include, for example, the LA1KN40 with 4 normally open contacts, the LA1KN22M with 2 normally open contacts, or the LA1KN11 with 1 normally open and 1 normally closed contact. Additionally, motor protection circuit breakers such as the GV2LE16 or GV2ME16 can be combined to protect the motor against overloads. For special requirements, delayed auxiliary switches such as the LA2KT2E or LA2KT2U are also available. Mounting is either on a panel or on a rail, enabling flexible installation in enclosures.
Mounting and Installation
Connections are made via screw terminals designed for various cable cross-sections: for rigid cables from 1.5 to 4 mm², for flexible cables without cable ends from 0.75 to 4 mm², and for flexible cables with cable ends from 0.34 to 2.5 mm². During installation, a tightening torque of 0.8 to 1.3 Nm must be observed, with the screw terminals tightened using a Phillips screwdriver No. 2, flat screws Ø 6, or position No. 2. The maximum operational rate is 3600 switching operations per hour, indicating high load capacity for continuous operation.
Advantages in Operation
The contactor offers high reliability with an operating time of 10 to 20 ms for coil energization and contact opening. The rated breaking capacity is 110 A at 440 V, enabling safe interruption even at high currents. The conventional thermal current is 20 A in the current circuit at 60 °C, ensuring high thermal load capacity. The associated fuse is specified as 25 A gG, ensuring safe protection of the contactor. Certifications according to UL and CSA confirm compliance with international safety standards.