Schneider Electric LC1K0910P7, EAN: 3389110364521

Schneider Electric LC1K0910P7 Contactor 3p 230VAC

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1K0910P7 Contactor 3p 230VAC

Lieske Part No. 517171
Mfg Part No LC1K0910P7
EAN-Code 3389110364521
Manufacturer Schneider Electric
Here only 45,89 EUR
54,61 EUR incl. VAT

Further information for Schneider Electric LC1K0910P7 Contactor 3p 230VAC

Complementary
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current9 A (at
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Motor power kW2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NO
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at = 0.20 Uc (at
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Coil technologyWithout built-in suppressor module
Auxiliary contacts typetype instantaneous 1 NO
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Operating time10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance0.5 mm
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 9 A AC-3 at Ue
Height58 mm
Width45 mm
Depth57 mm
Contractual warranty
Warranty (in months)18
Environment
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsCB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Protective treatmentTC conforming to IEC 60068; TC conforming to DIN 50016
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Logistical informations
Country of originFR
Main
RangeTeSys
Product or component typeContactor
Device applicationControl
Contactor applicationResistive load; Motor control
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.600 cm
Package 1 Width4.800 cm
Package 1 Length6.200 cm
Package 1 Weight177.000 g
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.146 kg
Unit Type of Package 3P06
Number of Units in Package 3800
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight162.980 kg
The contactor of the TeSys series by Schneider Electric, type LC1K0910P7, is a 3-pole contactor for controlling electrical loads, particularly for motor control and resistive loads. It features a coil with 230 V AC and is designed for operation in industrial, infrastructure, and building applications. The device application falls within the area of control, where the contactor is suitable for both simple machine control and integration into electronic control devices such as PLCs.

Applications

The contactor is designed for various usage categories, including AC-3, AC-3e, AC-1, and AC-4, with category AC-3 representing the standard application for motor drives. At an operating voltage of 380–415 V AC and an operating frequency of 50/60 Hz, the rated operational power is 4 kW and the operating rated current is 9 A. These values also apply to categories AC-3e and AC-4, while at 220–230 V AC, the motor power is reduced to 2.2 kW. The application thus covers both low-voltage installations and higher voltage levels up to 690 V AC.

Functions and Equipment in Detail

The device features 3 normally closed contacts in the main current circuit and an additional auxiliary contact (1 normally closed), which can be used for signaling and control purposes. The auxiliary contacts are of the type non-delayed, enabling direct and rapid response to control signals. The rated impulse voltage withstand is 8 kV, and the overvoltage category is III, confirming suitability for industrial environments with high electrical stress. The insulation resistances are over 10 MΩ for the signal circuit, ensuring high electrical safety.

Technology Explained Simply

The coil of the contactor is operated at 230 V AC and has an attracting power of 30 VA at 20 °C, as well as a holding power consumption of 4.5 VA. The operating time is 10–20 ms for coil de-energization and NO opening, as well as for coil energization and NO closing, enabling fast switching response. The heat dissipation is 1.3 W, limiting thermal stress during operation. The maximum operating rate is 3600 switching operations per hour, suitable for continuous and high loads.

Compatibility and Accessories

The contactor can be combined with various accessories to extend functionality. These include, for example, motor protection circuit breakers such as GV2ME14 or GV2LE14, auxiliary switch blocks such as LA1KN11M or LA1KN22, and motor protection relays such as LR2K0314. These components enable expansion of protection and control functions, especially in systems with increased safety requirements. Combining with a motor protection circuit breaker is typical to protect the motor against overload and short circuit.

Mounting and Installation

Connections are made via screw terminals, designed for various cable cross-sections: for rigid cables from 1.5 to 4 mm², for flexible cables without cable ends from 0.75 to 4 mm², and with cable ends from 0.34 to 2.5 mm². Mounting is done in standard control panels, with device dimensions of 45 mm (width), 58 mm (height), and 57 mm (depth). Mounting follows standards EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and other international standards.

Operational Advantages

The contactor offers a high mechanical life of 10 million switching cycles and an electrical life of 1.3 million cycles at 9 A AC-3. The rated short-time current withstand is up to 90 A for 1 second in the circuit, ensuring reliability under transient loads. The rated breaking capacity is 110 A for voltages up to 440 V and decreases for higher voltages according to IEC 60947 standards. The associated fuse is specified as 25 A gG, supporting the selection of the correct fuse for protecting the contactor. The safety levels according to EN/ISO 13849-1 are B10d = 1,369,863 cycles at rated load and B10d = 20,000,000 cycles at mechanical load, emphasizing reliability in safety-critical applications.

Certifications and Standards

The device complies with standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No. 60947-4-1, JIS C8201-4-1, as well as IEC 60335-1:Clause 30.2 and IEC 60335-2-40:Annex. Certifications according to CSA and UL confirm suitability for use in various markets, particularly in North America and Europe.