| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.20 Uc (at |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Auxiliary contacts type | type instantaneous 1 NO |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Operating time | 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| Contactor application | Motor control; Resistive load |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.600 cm |
| Package 1 Width | 4.800 cm |
| Package 1 Length | 6.200 cm |
| Package 1 Weight | 178.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 50 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.253 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 800 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 159.435 kg |
The LC1K0910B7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electric drives and resistive loads. It is designed for motor control in industrial, infrastructure, and building technology applications and enables easy integration into control systems such as PLCs. The device features a coil with a control circuit voltage of 24 V AC at 50/60 Hz and is rated for an operational current of 9 A. The rated operational power is 4 kW at 380–415 V AC (category AC-3), making it suitable for use with motors in the medium power class. The usage categories include AC-3, AC-3e, AC-1, and AC-4, making it suitable for drives with high inrush currents as well as resistive loads and intermittent operating modes.
Applications
This contactor is suitable for controlling electric motors in production plants, conveyor systems, pump and fan installations, as well as in building technology systems. The combination of robust design and high operating rate of up to 3600 switching operations per hour makes it suitable for continuously operated systems. Its application in building automation and infrastructure projects is supported by certifications according to CSA and UL.
Functions and Equipment in Detail
The device features a contact configuration of 3 main circuit make contacts and one additional auxiliary contact (1 make) in the signal circuit. The auxiliary contacts are instantaneous and allow integration into control logic, e.g. for feedback of switching states. The screw terminals are designed for cable cross-sections from 0.34 to 4 mm², supporting flexible cables with and without cable ends, as well as rigid cables. The maximum operating rate of 3600 switching operations per hour demonstrates the high load capacity of the device.
Technology Explained Simply
The contactor coil is supplied with 24 V AC and requires an inrush power of 30 VA at 20 °C and a holding power of 4.5 VA. The heat dissipation is 1.3 W, limiting the thermal load during operation. The rated impulse voltage withstand is 8 kV and the overvoltage category III ensures reliability during transient voltage surges. The rated breaking capacity is 110 A at 220–440 V and 70 A at 660–690 V, ensuring safety during short-circuit events. The mechanical life is 10 million switching cycles, and the electrical life is 1.3 million cycles at 9 A AC-3.
Compatibility and Accessories
The contactor can be combined with various accessories to extend its functionality. These include auxiliary switch blocks such as the LA1KN22 (2S+2Oe) or LA1KN11M (1S+1Oe), which provide additional switching functions for control circuits. Motor protection circuit breakers such as the GV2LE14 or GV2ME14 can be used for integration into motor protection concepts. Additional components such as overvoltage limiters (LA4KE1B) or energy meters (A9MEM1573) expand the application possibilities.
Mounting and Installation
The contactor is designed for mounting in standard control panels and complies with standards EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Dimensions are 45 mm width, 58 mm height, and 57 mm depth. Installation is done via screw terminals suitable for various cable types. The control circuit voltage range is between 0.8 and 1.15 times the nominal voltage, ensuring safe operational reliability.
Operational Advantages
The high mechanical and electrical life, along with robust construction, ensure long service life with minimal maintenance. The simple interface for PLC systems and support for auxiliary contacts facilitate integration into existing control systems. CSA and UL certifications increase acceptance in international projects. Low heat dissipation and high operating rate make the device suitable for continuously operated systems.
Safety Aspects
The contactor meets the requirements of EN/ISO 13849-1 with a safety level of B10d = 1,369,863 cycles at rated load and B10d = 20,000,000 cycles at mechanical load. The non-overlapping insulation distance is 0.5 mm, ensuring electrical safety. The associated fuse rating is 25 A gG to protect the circuit from overloads.
Standards and Certifications
The contactor complies with standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and JIS C8201-4-1. CSA and UL certifications support its use in international markets. The overvoltage category III and rated impulse voltage withstand of 8 kV ensure reliability during transient voltage surges.