Schneider Electric LC1K0901P7, EAN: 3389110363555

Schneider Electric LC1K0901P7 Contactor 3p 230VAC

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1K0901P7 Contactor 3p 230VAC

Lieske Part No. 309671
Mfg Part No LC1K0901P7
EAN-Code 3389110363555
Manufacturer Schneider Electric
Here only 45,16 EUR
53,74 EUR incl. VAT

Further information for Schneider Electric LC1K0901P7 Contactor 3p 230VAC

Complementary
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current9 A (at
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Motor power kW2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at = 0.20 Uc (at
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Coil technologyWithout built-in suppressor module
Auxiliary contacts typetype instantaneous 1 NC
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Operating time10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance0.5 mm
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 9 A AC-3 at Ue
Height58 mm
Width45 mm
Depth57 mm
Contractual warranty
Warranty (in months)18
Environment
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsCB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Protective treatmentTC conforming to IEC 60068; TC conforming to DIN 50016
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Logistical informations
Country of originFR
Main
RangeTeSys
Product or component typeContactor
Device applicationControl
Contactor applicationResistive load; Motor control
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.600 cm
Package 1 Width6.200 cm
Package 1 Length4.800 cm
Package 1 Weight180.000 g
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.341 kg
Unit Type of Package 3P06
Number of Units in Package 3400
Package 3 Height45.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight84.140 kg
Contactors, reversing contactors
small design ... LC-K, K-LP ...
AC operation 230 V 50/60 Hz, screw.
Power: 2.2 kW
Voltage: 400 V
Main contacts: 3 S
Auxiliary switch: 1 NC

Type: LC1-K0901P7
Quantity: 1 unit.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/309671
qrcode für Schneider Electric LC1K0901P7 Contactor 3p 230VAC