| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.20 Uc (at |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | With integral suppression device |
| Auxiliary contacts type | type instantaneous 1 NC |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting support | Plate; Rail |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.18 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| Contactor application | Resistive load; Motor control |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.900 cm |
| Package 1 Width | 6.200 cm |
| Package 1 Length | 7.000 cm |
| Package 1 Weight | 180.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 50 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.505 kg |
The LC1K0901F72 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor control and resistive loads. It features a contact configuration of 3 main circuit closers and one additional instantaneous opener in the auxiliary contact circuit. The coil is designed for a control circuit voltage of 110 V AC at 50/60 Hz, enabling universal use in industrial and infrastructure applications. The rated operational power is 4 kW at 380–415 V AC in usage category AC-3, corresponding to a rated operational current of 9 A. The coil is equipped with an integrated suppression unit incorporating a bidirectional amplitude limiter diode to minimize interference in the control circuit.
Applications
This contactor is suitable for applications in industry, infrastructure, and building automation where reliable and simple machine control is required. It is particularly suited for controlling electric motors in drive systems, pumps, fans, and other mechanical drives. The combination of AC-3, AC-4, and AC-1 usage categories allows use with various load types, including motor starting and stopping, as well as resistive loads.
Functions and Equipment in Detail
The device features screw terminals for connecting cables with cross-sections of 1.5 to 4 mm² (rigid) or 0.75 to 4 mm² (flexible without cable end), as well as for flexible tinned cables with 0.34 to 2.5 mm². Mounting is either on a plate or on a rail, enabling flexible integration into enclosures. The auxiliary contacts are instantaneous and provide a minimum switching voltage of 17 V and a minimum switching current of 5 mA in the signal circuit, ensuring reliability even with low signals. The pickup power is 30 VA, and the holding power consumption is 4.5 VA at 20 °C, enabling efficient energy use.
Technology Explained Simply
The integrated suppression unit with a bidirectional amplitude limiter diode suppresses voltage spikes in the control circuit caused by switching the coil. This protects control electronics and extends the contactor’s service life. The rated surge withstand voltage is 8 kV, ensuring high insulation strength against transient overvoltages. The overvoltage category III indicates suitability for applications in industrial environments with high electrical stress. The rated insulation voltage is 690 V for both the power circuit and signal circuit according to IEC 60947-4-1, ensuring safe isolation between main and control circuits.
Compatibility and Accessories
The contactor can be combined with various auxiliary switches, such as the LA1KN11 (1NO+1NC) or LA1KN31M (3NO+1NC), to realize additional switching functions. For motor protection applications, relays such as the LR2K0316 (8.0–11.5 A) or motor protection switches such as the GV2ME14 (6–10 A) are suitable. The use of labeling plates such as the LA9D90 enables clear identification in the enclosure. Combining with delayed auxiliary switches such as the LA2KT2E (delayed pickup 1–30 seconds) extends functionality for time-controlled sequences.
Mounting and Installation
Mounting is on a rail or plate, with the tightening torque for the screw terminals ranging from 0.8 to 1.3 Nm. Cable connections are made via screw terminals, with cross-sections varying depending on cable type and number of cables. The maximum operating rate is 3600 switching operations per hour, enabling high dynamic load capacity. The device’s heat dissipation is 1.3 W, which should be considered when planning cooling in the enclosure.
Operational Advantages
The contactor offers high reliability due to the integrated suppression unit and robust construction. The simple interface for electronic devices such as PLCs (Programmable Logic Controllers) enables seamless integration into automated systems. Certifications according to CSA and UL guarantee compliance with international safety and quality standards. The rated breaking capacity is up to 110 A at 440 V, enabling safe interruption of short-circuit currents. The rated short-time withstand current is defined for various durations, with the current value at 50 °C and 1 second being 90 A, ensuring load capacity under transient conditions.