| Additional features |
| Application category | AC-1 |
| Pole description | 4P |
| Pole contact composition | 2 S + 2 Ö |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 20 A (at |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 16 A (at 60 °C) for circuit; 10 A (at 50 °C) for signal circuit |
| [Irms] Rated making capacity | 110 A AC for circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220 - 230 V corresponds to IEC 60947; 110 A at 380 - 400 V corresponds to IEC 60947; 110 A at 415 V corresponds to IEC 60947; 110 A at 440 V corresponds to IEC 60947; 80 A at 500 V corresponds to IEC 60947; 70 A at 660 - 690 V corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 90 A 50 °C - 1 s for circuit; 85 A 50 °C - 5 s for circuit; 80 A 50 °C - 10 s for circuit; 60 A 50 °C - 30 s for circuit; 45 A 50 °C - 1 min for circuit; 40 A 50 °C - 3 min for circuit; 20 A 50 °C - >= 15 min. for circuit |
| Associated fuse | 25 A gG at |
| Average impedance | 3 MOhm - Ith 16 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Circuit: 600 V corresponds to UL 508; Circuit: 690 V corresponds to IEC 60947-4-1; Circuit: 600 V corresponds to CSA C22.2 No. 14 |
| Input power in VA | 30 VA (at 20 °C) |
| Hold power consumption in VA | 4.5 VA (at 20 °C) |
| Heat emission | 1,3 W |
| Control circuit voltage limits | Operation: 0.8 - 1.15 Uc (at = 0.20 Uc (at |
| Connections - terminals | Spring terminals 1 cable(s) 0.75…1.5 mm² solid; spring terminals 1 cable(s) 0.75…1.5 mm² fine-stranded without cable end; spring terminals 2 cable(s) 0.75…1.5 mm² fine-stranded without cable end |
| Max. operating rate | 3600 cyc/h |
| Coil technology | Without integrated switching module |
| Mounting bracket | Plate; rail |
| Operating time | 10 - 20 ms coil de-energisation and NO opening; 10 - 20 ms coil energisation and NO closing; 15 - 25 ms coil de-energisation and NC closing; 5 - 15 ms coil energisation and NC opening |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 10 Mcycles |
| Electrical lifetime | 0.16 Mcycles 20 A AC-1 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Product weight | 0,18 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys |
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| Application of contactor | resistive load |
| Mounting |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No. 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB certification; CCC; UL; CSA; EAC; CE; UKCA |
| Degree of protection (IP) | IP2x corresponds to VDE 0106 |
| Coating | TC corresponds to IEC 60068; TC corresponds to DIN 50016 |
| Ambient temperature during storage | -50…80 °C |
| Operating altitude | 2,000 m without derating |
| Flame retardancy | V1 corresponds to UL 94; Requirement 2 corresponds to NF F 16-101; Requirement 2 corresponds to NF F 16-102 |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 4,800 cm |
| VPE 1 width | 6,200 cm |
| VPE 1 length | 6,800 cm |
| Packaging weight (Lbs) | 186,000 g |
TeSys LC1K power contactor. 4-pole, 2 NO + 2 NC. Coil 230 V AC. Dimensions (WxHxD) 45x58x57 mm, weight 0.18 kg. Category AC-1. Simple machine control in industry, infrastructure and building applications. Easy-to-use interface for electronic devices (PLC). Certifications according to UL, CSA. Product standards in accordance with.