| Complementary |
| Utilisation category | AC-3; AC-3e; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 6 A (at |
| Control circuit type | AC at 50/60 Hz standard |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| Motor power kW | 1.5 kW at 220...230 V AC 50/60 Hz AC-3; 2.2 kW at 380...415 V AC 50/60 Hz AC-3; 3 kW at 440/690 V AC 50/60 Hz AC-3; 1.5 kW at 220...230 V AC 50/60 Hz AC-3e; 2.2 kW at 380...415 V AC 50/60 Hz AC-3e; 3 kW at 440/690 V AC 50/60 Hz AC-3e; 1.5 kW at 220...230 V AC 50/60 Hz AC-4; 2.2 kW at 380...415 V AC 50/60 Hz AC-4; 3 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947; 10 A gG for control circuit conforming to VDE 0660; 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Control circuit: 690 V conforming to BS 5424; Control circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to BS 5424; Power circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to NF C 20-040; Control circuit: 750 V conforming to VDE 0110 group C; Power circuit: 750 V conforming to VDE 0110 group C; Control circuit: 600 V conforming to CSA C22.2 No 14; Power circuit: 600 V UL 508 certified conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for control circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA 50/60 Hz (at 20 °C) |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc at 50/60 Hz (at = 0.20 Uc at 50/60 Hz (at |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Minimum switching current | 5 mA for control circuit |
| Minimum switching voltage | 17 V for control circuit |
| Mounting support | Plate; Rail |
| Operating time | 10...20 ms coil de-energisation and NO opening; 15...25 ms coil de-energisation and NC opening; 10...20 ms between energisation of coil and closing of NO contact; 5...15 ms coil energisation and NC opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 6 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.18 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | Class C2 conforming to NF F 16-101; Class C2 conforming to NF F 16-102; V1 conforming to UL 94 |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LC1K |
| Contactor application | Motor control |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.7 cm |
| Package 1 Width | 29.0 cm |
| Package 1 Length | 29.5 cm |
| Package 1 Weight | 172.0 g |
| Unit Type of Package 2 | CAR |
| Number of Units in Package 2 | 30 |
| Package 2 Height | 6.7 cm |
| Package 2 Width | 29.0 cm |
| Package 2 Length | 29.5 cm |
| Package 2 Weight | 5.227 kg |
| Unit Type of Package 3 | S06 |
| Number of Units in Package 3 | 300 |
| Package 3 Height | 73.5 cm |
| Package 3 Width | 60.0 cm |
| Package 3 Length | 80.0 cm |
| Package 3 Weight | 65.27 kg |
The LC1K0610B7TQ contactor from the TeSys series by Schneider Electric is a 3-pole contactor for motor control in industrial, infrastructure, and building applications. It features a contact configuration of 3 normally open (NO) contacts in the main circuit and one additional auxiliary contact as a normally open (NO) contact. The coil is designed for a control circuit voltage of 24 V AC at 50/60 Hz, enabling control via electronic devices such as PLCs. The device complies with product standards IEC 60947, VDE 0660, BS 5424, and NF C 63-110 and is certified according to UL, GOST, and CSA.
Applications
This contactor is suitable for controlling electric motors in manufacturing industry systems, building automation, and infrastructure applications. It is used in applications requiring safe and reliable switching functions for motors, particularly in categories AC-3, AC-3e, and AC-4. Category AC-3 refers to motor operation under normal load, while AC-4 is for frequent switching operations under high mechanical stress. Motor power ratings are 2.2 kW at 380–415 V AC, 1.5 kW at 220–230 V AC, and 3 kW at 440/690 V AC, in categories AC-3, AC-3e, and AC-4.
Functions and Equipment in Detail
The contactor has a rated operational current of 6 A in the main circuit. The rated breaking capacity is 110 A at voltages of 220–440 V and 70 A at 660–690 V, according to IEC 60947. The rated impulse voltage withstand is 8 kV, ensuring high insulation strength against transient voltage surges. The coil has an inrush power of 30 VA and a holding power consumption of 4.5 VA at 50/60 Hz. The control circuit voltage limits are between 0.8 and 1.15 times the nominal voltage (Uc) for operation and start at 0.20 Uc for de-energization.
Technology Explained Simply
The coil technology is designed without an integrated mounting module, enabling simple installation and maintenance. The screw terminals are designed for various cable cross-sections: for rigid conductors 1.5 to 4 mm², for flexible conductors without wire end ferrules 0.75 to 4 mm², and with wire end ferrules 0.34 to 2.5 mm². The maximum operating rate is 3600 switching operations per hour. The operating time is 10–20 ms between coil de-energization and opening of the NO contact, 15–25 ms for NC opening, and 10–20 ms between coil energization and closing of the NO contact. The rated short-time current withstand is 90 A for 1 second in the main circuit and 80 A for 1 second in the control circuit.
Compatibility and Accessories
The contactor can be combined with various motor protection relays from the LR2K series, such as the LR2K0303 (0.23–0.36 A) or LR2K0310 (2.6–3.7 A), to achieve complete motor control. Additionally, motor protection switches from the GV2ME and GV2LE series are available, designed for various rated currents. Auxiliary switch blocks such as the LA1KN11M (1 NO, 1 NC) or LA1KN40 (4 NO) can be used to extend control functions. Mounting is done on a panel or on a rail.
Mounting and Installation
Mounting is done either on a mounting plate or on a rail holder, enabling flexible integration into existing control panels. Connections are made via screw terminals designed for various cable types and cross-sections. The rated insulation voltage is 690 V for the main circuit and 690 V for the control circuit according to IEC 60947, while VDE 0110 Group C specifies an insulation strength of 750 V for both circuits. The associated fuse for the control circuit is 10 A gG according to IEC 60947 and VDE 0660.
Operational Advantages
The contactor offers high operational reliability through compliance with international standards. The low holding power consumption of 4.5 VA reduces energy consumption during operation. The high rated impulse voltage withstand of 8 kV protects the device against transient voltage surges. The maximum operating rate of 3600 switching operations per hour enables use in applications with high switching frequency. The simple interface for PLC control facilitates integration into automated systems. Mounting on panel or rail provides flexibility during installation in various control panels.