Schneider Electric LC1K0601U7TQ, EAN: 3389110076790

Schneider Electric LC1K0601U7TQ Contactor 3p 6A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1K0601U7TQ Contactor 3p 6A

Lieske Part No. 556090
Mfg Part No LC1K0601U7TQ
EAN-Code 3389110076790
Manufacturer Schneider Electric
Here only 1.315,86 EUR
1.565,87 EUR incl. VAT

Further information for Schneider Electric LC1K0601U7TQ Contactor 3p 6A

Complementary
Utilisation categoryAC-3; AC-3e; AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current6 A (at
Control circuit typeAC at 50/60 Hz standard
[Uc] control circuit voltage230...240 V AC 50/60 Hz
Motor power kW1.5 kW at 220...230 V AC 50/60 Hz AC-3; 2.2 kW at 380...415 V AC 50/60 Hz AC-3; 3 kW at 440/690 V AC 50/60 Hz AC-3; 1.5 kW at 220...230 V AC 50/60 Hz AC-3e; 2.2 kW at 380...415 V AC 50/60 Hz AC-3e; 3 kW at 440/690 V AC 50/60 Hz AC-3e; 1.5 kW at 220...230 V AC 50/60 Hz AC-4; 2.2 kW at 380...415 V AC 50/60 Hz AC-4; 3 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for control circuit conforming to IEC 60947; 10 A gG for control circuit conforming to VDE 0660; 25 A gG at
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltageControl circuit: 690 V conforming to BS 5424; Control circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to BS 5424; Power circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to NF C 20-040; Control circuit: 750 V conforming to VDE 0110 group C; Power circuit: 750 V conforming to VDE 0110 group C; Control circuit: 600 V conforming to CSA C22.2 No 14; Power circuit: 600 V UL 508 certified conforming to CSA C22.2 No 14
Insulation resistance> 10 MOhm for control circuit
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA 50/60 Hz (at 20 °C)
Control circuit voltage limitsOperational: 0.8...1.15 Uc at 50/60 Hz (at = 0.20 Uc at 50/60 Hz (at
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Coil technologyWithout built-in suppressor module
Minimum switching current5 mA for control circuit
Minimum switching voltage17 V for control circuit
Mounting supportPlate; Rail
Operating time10...20 ms coil de-energisation and NO opening; 15...25 ms coil de-energisation and NC opening; 10...20 ms between energisation of coil and closing of NO contact; 5...15 ms coil energisation and NC opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 6 A AC-3 at Ue
Height58 mm
Width45 mm
Depth57 mm
Net weight0.18 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsEN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1
Product certificationsCB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceClass C2 conforming to NF F 16-101; Class C2 conforming to NF F 16-102; V1 conforming to UL 94
Main
RangeTeSys
Product or component typeContactor
Device short nameLC1K
Contactor applicationMotor control
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.0 cm
Package 1 Width29.0 cm
Package 1 Length29.5 cm
Package 1 Weight180.0 g
Unit Type of Package 2CAR
Number of Units in Package 230
Package 2 Height7.0 cm
Package 2 Width29.0 cm
Package 2 Length29.5 cm
Package 2 Weight5.4 kg
TeSys LC1K power contactor. 3 pole, 3 NO contacts. Additional auxiliary contacts - 1 NC contact, rated operational power at AC-3, 400 V 2.2 kW, rated operational current Ie at AC-3, 400 V 6 A, coil 240 V AC. Dimensions (WxHxD) 45x58x57 mm, weight 0.18 kg. Category AC-3, AC-4. Coil - AC 50/60 Hz, without built-in amplitude limiter diode. Simple machine control in industry, infrastructure and building applications. Easy-to-use interface for electronic devices (PLC). Certifications according to GOST, CSA, UL. Product standards according to IEC 60947, NF C 63-110, VDE 0660, BS 5424.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/556090
qrcode für Schneider Electric LC1K0601U7TQ Contactor 3p 6A