| Additional features |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| [Ith] conventional thermal current in free air | 1250 A (at 40 °C) |
| Rated breaking capacity | 8 kA corresponds to IEC 60947-4-1 |
| [Icw] rated short-time current withstand | 10000 A 40 °C - 10 s; 7500 A 40 °C - 30 s; 5500 A 40 °C - 1 min; 4200 A 40 °C - 3 min; 3000 A 40 °C - 10 min |
| Associated fuse | 1400 A gG at |
| Average impedance | 0.1 MOhm - Ith 1250 A 50 Hz |
| [Ui] Rated insulation voltage | 1000 V corresponds to IEC 60947-4-1; 1500 V corresponds to VDE 0110 Group C |
| Power dissipation per pole | 200 W AC-1 |
| Over voltage category | III |
| Pole contact composition | 3 S |
| Max. operating rate | 600 cyc/h 55 °C |
| Operating time | 40 - 80 ms closing; 100 - 200 ms opening |
| Connections - terminals | Control circuit: Screw terminals 1 cable(s) 1…4 mm² flexible without ferrule; Control circuit: Screw terminals 2 cable(s) 1…4 mm² flexible without ferrule; Control circuit: Screw terminals 1 cable(s) 1…4 mm² flexible with ferrule; Control circuit: Screw terminals 2 cable(s) 1…2.5 mm² flexible with ferrule; Control circuit: Screw terminals 1 cable(s) 1…4 mm² solid without ferrule; Control circuit: Screw terminals 2 cable(s) 1…4 mm² solid without ferrule; Power circuit: Bar 3 cable(s); Power circuit: Bar 4 cable(s) |
| Mounting bracket | Plate |
| Motor power range | 315 kW at 220…230 V 3-phase; 560 kW at 380…400 V 3-phase; 630 kW at 415 V 3-phase; 670 kW at 440 V 3-phase |
| Type of motor starter | Direct contact starter |
| Contactor coil voltage | 230 V AC standard |
| Standards | IEC 60947-4-1; EN 60947-1; IEC 60947-1; EN 60947-4-1 |
| Product certifications | CSA; CCC; CB; UKCA |
| Compatibility code | LC1F |
| Control circuit type | AC at 40 - 400 Hz |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys |
| Product or component type | Contactor |
| Device short name | LC1F |
| Application of contactor | Motor control; resistive load |
| Application category | AC-1; AC-3 |
| Pole description | 3P |
| [Uc] control circuit voltage | 230 V AC 40 - 400 Hz |
| [Ie] rated operational current | 1250 A (at |
| Mounting |
| Degree of protection (IP) | IP20 front with protective covers, complies with IEC 60529; IP20 front with protective covers, complies with VDE 0106 |
| Coating | TH |
| Operating ambient temperature | -5…40 °C |
| Ambient temperature during storage | -60…80 °C |
| Device ambient temperature | -40…60 °C |
| Height | 332 mm |
| Width | 438 mm |
| Depth | 238,6 mm |
| Installation height | 3,000 m without power derating |
| Product weight | 31 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 53,000 cm |
| VPE 1 width | 60,000 cm |
| VPE 1 length | 80,000 cm |
| Packaging weight (Lbs) | 40,500 kg |