Schneider Electric LC1E1801M5, EAN: 3606480328152

Schneider Electric LC1E1801M5 contactor 3P 18A 1NC 220VAC

Schneider Electric LC1E1801M5 contactor 3P 18A 1NC 220VAC

Lieske Part No. 1017885
Mfg Part No LC1E1801M5
EAN-Code 3606480328152
Manufacturer Schneider Electric
Here only 66,50 EUR
79,13 EUR incl. VAT

Further information for Schneider Electric LC1E1801M5 contactor 3P 18A 1NC 220VAC

Additional features
Motor power (kW)4 kW at 220/230 V AC 50/60 Hz; 7.5 kW at 380/400 V AC; 9 kW at 415/440 V AC; 9 kW at 500 V AC; 9 kW at 660/690 V AC; 10 kW at 660 - 690 V
Pole contact composition3 S
[Ith] conventional thermal current in free air32 A (at 55 °C) for circuit
[Irms] Rated making capacity234 A at 440 V AC for circuit conforming to IEC 60947-4-1
Rated breaking capacity153 A at 440 V for circuit corresponds to IEC 60947
[Icw] rated short-time current withstand145 A 40 °C - 10 s for circuit; 84 A 40 °C - 60 s for circuit; 40 A 40 °C - 600 s for circuit
Associated fuse35 A gG at
Average impedance2.5 MOhm - Ith 32 A 50 Hz for circuit
Power dissipation per pole0,81 W AC-3; 2,6 W AC-1
[Ui] Rated insulation voltage690 V corresponds to IEC 60947-4-1
Over voltage categoryIII
Pollution degree3
[Uimp] Rated impulse voltage withstand6 kV coil not connected to power circuit, complies with IEC 60947
Mechanical life10000000 cycles
Electrical lifetime300000 cycles AC-1; 1200000 cycles AC-3
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85 - 1.1 Uc (-5…55 °C): Operation 50 Hz; 0.3 - 0.6 Uc (-5…55 °C): Dropout voltage 50 Hz
Input power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C); 95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C); 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat emission2…3 W for control circuit
Operating time12 - 22 ms on closing; 4 - 19 ms on opening
Max. operating rate1800 cyc/h 60 °C
Tightening momentMain circuit: 1.2 Nm; Control circuit: 1.2 Nm
Configuration of auxiliary contacts1 Ö
Min. switching voltage17 V for auxiliary contact circuit
Min. switching current5 mA for auxiliary contact circuit
Insulation resistance> 10 MOhm for auxiliary contact circuit
Non-overlapping time1.5 ms guaranteed between normally closed and normally open contact on energizing; 1.5 ms guaranteed between normally closed and normally open contact on de-energizing
Mounting bracketPlate; DIN rail
Contractual warranty
Warranty (in months)18
Main features
Product seriesEasy TeSys
Product or component typeContactor
Device short nameLC1E
Application of contactorMotor control; resistive load
Application categoryAC-3; AC-3e; AC-1
Pole description3P
[Ue] Rated operational voltageCircuit:
[Ie] rated operational current18 A (at
[Uc] control circuit voltage220 V AC 50 Hz
Mounting
StandardsEN/IEC 60947-1; EN/IEC 60947-4-1; EN/IEC 60947-5-1; GB/T 14048.1; GB/T 14048.4; GB/T 14048.5; EN/IEC 60335-1:Clause 30.2; EN/IEC 60335-2-40:Annex JJ; IS/IEC 60947-1; IS/IEC 60947-4-1; IS/IEC 60947-5-1
Product certificationsCB Scheme; CCC; CE; EAC; BIS
Degree of protection (IP)IP2x complies with IEC 60529
Protection treatmentTH (pollution degree 3) corresponds to IEC 60068-2-30 Test Db
Device ambient temperature-20…70 °C at Uc; -60…80 °C storage; -5…55 °C operation
Operating altitude3,000 m without power derating
Fire-resistance850 °C corresponds to IEC 60695-2-1
Mechanical robustnessVibrations, contact open (1.5 Gn, 5 - 300 Hz); Vibrations, contact closed (3 Gn, 5 - 300 Hz); Shocks, contact open (7 Gn for 11 ms); Shocks, contact closed (10 Gn for 11 ms)
Height74 mm
Width45 mm
Depth80 mm
Product weight0,3 kg
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height5,000 cm
VPE 1 width7,700 cm
VPE 1 length8,900 cm
Packaging weight (Lbs)339,800 g
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1017885
qrcode für Schneider Electric LC1E1801M5 contactor 3P 18A 1NC 220VAC