| Complementary |
| Compatibility code | LC1D |
| Pole contact composition | 4 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 25 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 250 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 1.56 W AC-1 |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 0.8 Mcycles 25 A AC-1 at Ue |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 4...19 ms opening; 12...22 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1 |
| Product certifications | DNV; GL; CCC; LROS (Lloyds register of shipping); RINA; BV; GOST; UL; CSA; CB |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms) |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 92 mm |
| Net weight | 0.365 kg |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range | TeSys; TeSys Deca |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load |
| Utilisation category | AC-1 |
| Poles description | 4P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 25 A (at |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 12.000 cm |
| Package 1 Weight | 392.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 6.696 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 256 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 118.064 kg |
The LC1DT25P7 contactor from the TeSys Deca series by Schneider Electric is a 4-pole contactor with a rated operational current of 25 A and a control circuit voltage of 230 V AC at 50/60 Hz. It is designed for use with resistive loads and corresponds to usage category AC-1. The device features a contact configuration of 4 make contacts in the main current circuit and integrated auxiliary contacts in the configuration of 1 make + 1 break, which are mechanically linked to ensure secure signal transmission. The auxiliary contacts comply with standards IEC 60947-5-1 and IEC 60947-4-1, with the type specified as mirror contact for the signal circuit. The coil operates without an integrated control module, enabling simple installation and maintenance.
Applications
This contactor is designed for industrial applications, particularly in control systems requiring safe and reliable switching of power. The mechanically linked auxiliary contacts make it suitable for safety applications where monitoring the contactor’s status is required. Certifications according to UL, CSA, BV, CCC, LROS, DNV, RINA, GOST, and GL confirm its suitability for international operating conditions, including marine and heavy industrial environments.
Functions and Equipment in Detail
Current connections are made via Everlink and spring terminals, ensuring a secure and long-lasting connection. The tightening torque for screw terminals is 1.7 Nm, and both flathead screwdrivers (Ø 6) and Phillips screwdrivers (No. 2) can be used. The operating time is 4 to 19 ms for opening and 12 to 22 ms for closing. The maximum operating rate is 3600 switching cycles per hour at an ambient temperature of 60 °C. The heat dissipation is 2 to 3 W at 50/60 Hz.
Technology Explained Simply
The rated impulse voltage withstand is 6 kV, ensuring high electrical strength. The rated breaking capacity is 250 A at 440 V for the current circuit, demonstrating the contactor’s ability to interrupt high currents under defined conditions. The rated making capacity is 250 A for the current circuit at 440 V. The conventional thermal current (Ith) is 25 A for the current circuit at 60 °C.
Compatibility and Accessories
The contactor is compatible with various accessories, including auxiliary switch blocks such as LADN02, LADN22S, LAD8N02, LADN20, LADN13, LAD8N11, and timing blocks such as LADT0, LADT2, LAD-R4, LAD-S2. Additionally, motor protection circuit breakers such as GV2L22, GV2ME22, GV2P22, GV2LE22 and motor protection relays such as LRD22 are available. Interlocking elements such as LAD9V2 and interlock blocks such as LAD6K10M can be used to extend functionality. The control module LAD4RCU is available for other models in the LC1D series, but is not integrated in this model.
Mounting and Installation
Mounting is done via screw terminals with a tightening torque of 1.7 Nm. Dimensions are 45 mm (width) × 85 mm (height) × 92 mm (depth). The device features a safety cover that allows secure access to the contacts. The control circuit voltage limits are 0.3 to 0.6 Uc for drop-out voltage and 0.8 to 1.1 Uc for operation at 50 Hz, and 0.85 to 1.1 Uc at 60 Hz. At temperatures of 60 to 70 °C, the operating range is 1 to 1.1 Uc.
Operational Advantages
The contactor offers a high mechanical life of 15 million switching cycles and an electrical life of 0.8 million switching cycles at 25 A AC-1 and rated voltage. The power loss per pole is 1.56 W at AC-1. The pickup power is 70 VA at 50 Hz and 60 Hz, and the holding power consumption is 7 VA at 50 Hz and 7.5 VA at 60 Hz. The average impedance is 2.5 MΩ at Ith 25 A and 50 Hz for the current circuit. The associated fuse for the signal circuit is 10 A gG, and for the current circuit 40 A gG. The rated short-time current withstand is defined for various durations: 30 A for 10 minutes, 61 A for 1 minute, 105 A for 10 seconds, 210 A for 1 second in the current circuit; 100 A for 1 second, 120 A for 500 ms, 140 A for 100 ms in the signal circuit. The signal circuit frequency range is between 25 and 400 Hz, and the minimum switching voltage is 17 V for the signal circuit.
Safety Level and Standards Compliance
The contactor meets the requirements of standard EN/ISO 13849-1 with a safety level B10d of 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load. The overvoltage category III and pollution degree 3 ensure high reliability in dirty and electrically stressed environments. Certifications according to UL, CSA, BV, CCC, LROS, DNV, RINA, GOST, and GL confirm compliance with international standards.