Schneider Electric LC1D95MD, EAN: 3389110451559

Schneider Electric LC1D95MD contactor 3p 95A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D95MD contactor 3p 95A

Lieske Part No. 493234
Mfg Part No LC1D95MD
EAN-Code 3389110451559
Manufacturer Schneider Electric
Here only 620,91 EUR
738,88 EUR incl. VAT

Further information for Schneider Electric LC1D95MD contactor 3p 95A

Additional features
Motor power HP (UL / CSA standards)7.5 hp at 120 V AC 60 Hz for 1-phase motors; 15 hp at 230/240 V AC 60 Hz for 1-phase motors; 30 hp at 200/208 V AC 60 Hz for 3-phase motors; 30 hp at 230/240 V AC 60 Hz for 3-phase motors; 60 hp at 460/480 V AC 60 Hz for 3-phase motors; 60 hp at 575/600 V AC 60 Hz for 3-phase motors
Compatibility codeLC1D
Pole contact composition3 S
Safety coverWith
[Ith] conventional thermal current in free air10 A (at 60 °C) for signal circuits; 125 A (at 60 °C) for power circuits
[Irms] Rated making capacity1100 A at 440 V AC for circuit conforming to IEC 60947; 140 A AC for signal circuit conforming to IEC 60947-5-1; 250 A DC for signal circuit conforming to IEC 60947-5-1
Rated breaking capacity1100 A at 440 V for circuit, corresponds to IEC 60947
[Icw] rated short-time current withstand1100 A 40 °C - 1 s for power circuit; 800 A 40 °C - 10 s for power circuit; 400 A 40 °C - 1 min for power circuit; 135 A 40 °C - 10 min for power circuit; 140 A - 100 ms for signal circuit; 120 A - 500 ms for signal circuit; 100 A - 1 s for signal circuit
Associated fuse10 A gG for signal circuits complies with IEC 60947-5-1; 200 A gG at
Average impedance0.8 MOhm - Ith 125 A 50 Hz for circuit
Power dissipation per pole12,5 W AC-1; 7,2 W AC-3; 7,2 W AC-3e
[Ui] Rated insulation voltageCircuit: 1000 V corresponds to IEC 60947-4-1; Signal circuit: 690 V corresponds to IEC 60947-1
Over voltage categoryIII
Pollution degree3
[Uimp] Rated impulse voltage withstand8 kV corresponds to IEC 60947
Security level ratingB10d = 1.3 Mcycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20 Mcycles contactor with mechanical load corresponds to EN/ISO 13849-1
Mechanical life10 Mcycles
Electrical lifetime1.2 Mcycles 95 A AC-3; 1.3 Mcycles 125 A AC-1; 1.2 Mcycles 95 A AC-3e
Control circuit typeDC Standard
Coil technologyWithout integrated switching module
Control circuit voltage limits0.1 - 0.3 Uc (-40…70 °C): drop-out voltage DC; 0.85 - 1.1 Uc (-40…55 °C): operation DC; 1 - 1.1 Uc (55…70 °C): operation DC
Absorption power in W22 W (at 20 °C)
Holding power consumption in W22 W at 20 °C
Operating time95 - 130 ms closing; 20 - 35 ms opening
Time constant75 ms
Maximum operating rate3600 cyc/h at 60 °C
Tightening momentControl circuit: 1.2 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.2 Nm - on screw terminals - with Phillips screwdriver No. 2; Power circuit: 12 Nm - on connectors - with flat screwdriver Ø 6 to Ø 8; Power circuit: 12 Nm - on connectors hexagonal screw head 4 mm; Control circuit: 1.2 Nm - on screw terminals - with screwdriver position No. 2
Configuration of auxiliary contacts1 S + 1 Ö
Type of auxiliary contactsMechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1
Signalling angular frequency25 - 400 Hz
Min. switching voltage17 V for signal circuit
Min. switching current5 mA for signal circuit
Insulation resistance> 10 MΩ for signal circuits
Non-overlapping time1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact
Mounting bracketPlate; rail
Contractual warranty
Warranty (in months)18
Main features
Product seriesTeSys
Product or component typeContactor
Device short nameLC1D
Application of contactorMotor control; resistive load
Application categoryAC-3; AC-3e; AC-1; AC-4
Pole description3P
[Ue] Rated operational voltageCircuit:
[Ie] rated operational current95 A (at
[Uc] control circuit voltage220 V DC
Mounting
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No. 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product certificationsIECEE CB-Scheme; CCC; EAC; LROS (Lloyds register of shipping); RINA; BV; DNV-GL
Degree of protection (IP)IP20 front side corresponds to IEC 60529
Protection treatmentTH corresponds to IEC 60068-2-30
Climate resistancecomplies with IACS E10 damp heat exposure
Device ambient temperature-40…60 °C; 60…70 °C with power reduction
Operating altitude0 - 3.000 m
Fire-resistance850 °C corresponds to IEC 60695-2-1
Flame retardancyV1 corresponds to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5 - 300 Hz); shocks contactor open (8 Gn for 11 ms); vibrations contactor closed (3 Gn, 5 - 300 Hz); shocks contactor closed (10 Gn for 11 ms)
Height127 mm
Width85 mm
Depth186 mm
Product weight2,61 kg
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height21,0 cm
VPE 1 width10,0 cm
VPE 1 length14,0 cm
Packaging weight (Lbs)2,644 kg
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 45 kW, rated operating current Ie at AC-3, 400 V 95 A, coil 220 V DC. Dimensions (WxHxD) 85x127x186 mm, weight 2.61 kg. Category AC-3, AC-1, AC-4. Without integrated circuit module. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to BV, RINA, GOST, CCC, GL, DNV, LROS (Lloyds register of shipping). Product standards in accordance with.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/493234