| Additional features |
| Motor power HP (UL / CSA standards) | 7.5 hp at 120 V AC 60 Hz for 1-phase motors; 15 hp at 230/240 V AC 60 Hz for 1-phase motors; 30 hp at 200/208 V AC 60 Hz for 3-phase motors; 30 hp at 230/240 V AC 60 Hz for 3-phase motors; 60 hp at 460/480 V AC 60 Hz for 3-phase motors; 60 hp at 575/600 V AC 60 Hz for 3-phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 S |
| Safety cover | With |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for signal circuits; 125 A (at 60 °C) for power circuits |
| [Irms] Rated making capacity | 1100 A at 440 V AC for circuit conforming to IEC 60947; 140 A AC for signal circuit conforming to IEC 60947-5-1; 250 A DC for signal circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1100 A at 440 V for circuit, corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 1100 A 40 °C - 1 s for power circuit; 800 A 40 °C - 10 s for power circuit; 400 A 40 °C - 1 min for power circuit; 135 A 40 °C - 10 min for power circuit; 140 A - 100 ms for signal circuit; 120 A - 500 ms for signal circuit; 100 A - 1 s for signal circuit |
| Associated fuse | 10 A gG for signal circuits complies with IEC 60947-5-1; 200 A gG at |
| Average impedance | 0.8 MOhm - Ith 125 A 50 Hz for circuit |
| Power dissipation per pole | 12,5 W AC-1; 7,2 W AC-3; 7,2 W AC-3e |
| [Ui] Rated insulation voltage | Circuit: 1000 V compliant with IEC 60947-4-1; Circuit: 600 V CSA certified; Circuit: 600 V UL certified; Signal circuit: 690 V compliant with IEC 60947-1; Signal circuit: 600 V CSA certified; Signal circuit: 600 V UL certified |
| Over voltage category | III |
| Pollution degree | 3 |
| [Uimp] Rated impulse voltage withstand | 8 kV corresponds to IEC 60947 |
| Security level rating | B10d = 1.3 Mcycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20 Mcycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 4 Mcycles |
| Electrical lifetime | 1.2 Mcycles 95 A AC-3; 1.3 Mcycles 125 A AC-1; 1.2 Mcycles 95 A AC-3e |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without integrated switching module |
| Control circuit voltage limits | 0.8 - 1.1Uc (-40…55 °C): operation AC 50 Hz; 0.85 - 1.1 Uc (-40…55 °C): operation AC 60 Hz; 0.3 - 0.6 Uc (-40…70 °C): drop-out voltage AC 50/60 Hz; 1 - 1.1 Uc (55…70 °C): operation AC 50/60 Hz |
| Input power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C); 245 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold power consumption in VA | 26 VA 60 Hz cos phi 0,3 (at 20 °C); 26 VA 50 Hz cos phi 0,3 (at 20 °C) |
| Heat emission | 6…10 W at 50/60 Hz |
| Operating time | 20 - 35 ms closing; 6 - 20 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening moment | Control circuit: 1.2 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.2 Nm - on screw terminals - with Phillips screwdriver No. 2; Power circuit: 12 Nm - on connectors - with flat screwdriver Ø 6 to Ø 8; Power circuit: 12 Nm - on connectors hexagonal screw head 4 mm; Control circuit: 1.2 Nm - on screw terminals - with screwdriver position No. 2 |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching voltage | 17 V for signal circuit |
| Min. switching current | 5 mA for signal circuit |
| Insulation resistance | > 10 MΩ for signal circuits |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Mounting bracket | Plate; rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys |
| Product or component type | Contactor |
| Device short name | LC1D |
| Application of contactor | Resistive load; motor control |
| Application category | AC-3; AC-3e; AC-1; AC-4 |
| Pole description | 3P |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 95 A (at |
| [Uc] control circuit voltage | 120 V AC 50/60 Hz |
| Mounting |
| Standards | EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No. 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2 |
| Product certifications | CCC; UL; CB regulation; CSA; CE; UKCA; Marine; EAC |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Protection treatment | TH corresponds to IEC 60068-2-30 |
| Climate resistance | complies with IACS E10 damp heat exposure |
| Device ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Flame retardancy | V1 corresponds to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5 - 300 Hz); shocks contactor open (8 Gn for 11 ms); vibrations contactor closed (3 Gn, 5 - 300 Hz); shocks contactor closed (10 Gn for 11 ms) |
| Height | 127 mm |
| Width | 85 mm |
| Depth | 130 mm |
| Product weight | 1,61 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 15,500 cm |
| VPE 1 width | 9,500 cm |
| VPE 1 length | 13,500 cm |
| Packaging weight (Lbs) | 1,600 kg |
| VPE 2 type | S03 |
| VPE 2 quantity | 8 |
| VPE 2 height | 30 cm |
| VPE 2 width | 30 cm |
| VPE 2 length | 40 cm |
| VPE 2 weight | 13,220 kg |
| VPE 3 type | P06 |
| VPE 3 quantity | 64 |
| VPE 3 height | 75,000 cm |
| VPE 3 width | 80,000 cm |
| VPE 3 length | 60,000 cm |
| VPE 3 weight | 113,760 kg |
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 45 kW, rated operating current Ie at AC-3, 400 V 95 A, coil 120 V AC. Dimensions (WxHxD) 85x127x130 mm, weight 1.61 kg. Category AC-4, AC-3, AC-1. Without integrated circuit module. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to RINA, GOST, BV, GL, DNV, LROS (Lloyds register of shipping), CCC. Product standards in accordance with.