Schneider Electric LC1D80FD, EAN: 3389110440584

Schneider Electric LC1D80FD contactor 3p 80A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D80FD contactor 3p 80A

Lieske Part No. 583102
Mfg Part No LC1D80FD
EAN-Code 3389110440584
Manufacturer Schneider Electric
Here only 564,59 EUR
671,86 EUR incl. VAT

Further information for Schneider Electric LC1D80FD contactor 3p 80A

Complementary
Motor power kW22 kW at 220/230 V AC 50/60 Hz (AC-3); 37 kW at 380/400 V AC 50/60 Hz (AC-3); 45 kW at 415/440 V AC 50/60 Hz (AC-3); 55 kW at 500 V AC 50/60 Hz (AC-3); 45 kW at 660/690 V AC 50/60 Hz (AC-3); 45 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 220/230 V AC 50/60 Hz (AC-3e); 37 kW at 380/400 V AC 50/60 Hz (AC-3e); 45 kW at 415/440 V AC 50/60 Hz (AC-3e); 55 kW at 500 V AC 50/60 Hz (AC-3e); 45 kW at 660/690 V AC 50/60 Hz (AC-3e); 45 kW at 1000 V AC 50/60 Hz (AC-3e); 15 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp7.5 hp at 120 V AC 50/60 Hz for 1 phase motors; 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 125 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current640 A 40 °C - 10 s for power circuit; 990 A 40 °C - 1 s for power circuit; 135 A 40 °C - 10 min for power circuit; 320 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 200 A gG at
Average impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole5.1 W AC-3; 12.5 W AC-1; 5.1 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability4 Mcycles
Electrical durability0.8 Mcycles 125 A AC-1 at Ue
Control circuit typeDC standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.1...0.3 Uc (-40…70 °C):drop-out DC; 0.85...1.1 Uc (-40…55 °C):operational DC; 1...1.1 Uc (55…70 °C):operational DC
Inrush power in W22 W (at 20 °C)
Hold-in power consumption in W22 W at 20 °C
Operating time95...130 ms closing; 20...35 ms opening
Time constant75 ms
Maximum operating rate3600 cyc/h at 60 °C
Tightening torqueControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product certificationsCCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Shocks contactor open (8 Gn for 11 ms) ; Vibrations contactor closed (3 Gn, 5...300 Hz) ; Shocks contactor closed (10 Gn for 11 ms)
Height127 mm
Width85 mm
Depth186 mm
Net weight2.59 kg
Logistical informations
Country of originCZ
Main
RangeTeSys
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current125 A (at
[Uc] control circuit voltage110 V DC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.8 cm
Package 1 Width13.6 cm
Package 1 Length21.2 cm
Package 1 Weight2.509 kg
Unit Type of Package 2S02
Number of Units in Package 22
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.52 kg
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 37 kW, rated operating current Ie at AC-3, 400 V 80 A, coil 110 V DC. Dimensions (WxHxD) 85x127x186 mm, weight 2.59 kg. Category AC-4, AC-1, AC-3. Without integrated circuit module. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to RINA, CCC, GOST, CSA, GL, BV, UL, DNV, LROS (Lloyds register of shipping).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/583102
qrcode für Schneider Electric LC1D80FD contactor 3p 80A