| Complementary |
| Motor power kW | 22 kW at 220/230 V AC 50/60 Hz (AC-3); 37 kW at 380/400 V AC 50/60 Hz (AC-3); 45 kW at 415/440 V AC 50/60 Hz (AC-3); 55 kW at 500 V AC 50/60 Hz (AC-3); 45 kW at 660/690 V AC 50/60 Hz (AC-3); 45 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 220/230 V AC 50/60 Hz (AC-3e); 37 kW at 380/400 V AC 50/60 Hz (AC-3e); 45 kW at 415/440 V AC 50/60 Hz (AC-3e); 55 kW at 500 V AC 50/60 Hz (AC-3e); 45 kW at 660/690 V AC 50/60 Hz (AC-3e); 45 kW at 1000 V AC 50/60 Hz (AC-3e); 15 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors; 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 125 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1100 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 135 A 40 °C - 10 min for power circuit; 320 A 40 °C - 1 min for power circuit; 640 A 40 °C - 10 s for power circuit; 990 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 200 A gG at |
| Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
| Power dissipation per pole | 5.1 W AC-3; 12.5 W AC-1; 5.1 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 1000 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.5 Mcycles 80 A AC-3 at Ue |
| Control circuit type | AC at 50 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50 Hz; 0.85...1.1 Uc (-40…55 °C):operational AC 50 Hz; 1...1.1 Uc (55…70 °C):operational AC 50 Hz |
| Inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 20 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 6…10 W at 50 Hz |
| Operating time | 20...35 ms closing; 6...20 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque | Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2 |
| Product certifications | CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Shocks contactor open (8 Gn for 11 ms) ; Vibrations contactor closed (3 Gn, 5...300 Hz) ; Shocks contactor closed (10 Gn for 11 ms) |
| Height | 127 mm |
| Width | 85 mm |
| Depth | 130 mm |
| Net weight | 1.59 kg |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 80 A (at |
| [Uc] control circuit voltage | 24 V AC 50 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.6 cm |
| Package 1 Width | 14.0 cm |
| Package 1 Length | 14.0 cm |
| Package 1 Weight | 1.56 kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 9.742 kg |
The LC1D80B5 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for motor control and operation with resistive loads. It is designed for use in industrial plants where reliable and safe switching functions are required under high loads. The device has a rated operational power of 37 kW at 400 V and AC-3 duty, with a rated operational current of 80 A. The control circuit voltage is 24 V AC at 50 Hz. The coil is supplied without an integrated control module, enabling flexible integration into existing control systems.
This contactor is suitable for controlling electric motors in various application areas, particularly in manufacturing, process engineering, and machine building. It covers usage categories AC-1, AC-3, AC-3e, and AC-4, with AC-3 being the standard category for motor drives. Motor power ratings according to UL/CSA standards range from 7.5 hp at 120 V to 60 hp at 575/600 V for three-phase motors. The application also includes resistive loads, with an electrical life of 1.5 million switching cycles at 80 A and AC-3 duty.
The contactor features three main circuit closing contacts and additional auxiliary contacts configured as 1 closing + 1 opening. The auxiliary contacts are mechanically linked, ensuring secure signal transmission in control and safety systems. The contacts are designed for a maximum operating rate of 3600 switching cycles per hour at 60 °C. The operating time is 20–35 ms for closing and 6–20 ms for opening. The pickup power is 200 VA at 50 Hz, and the holding power consumption is 20 VA at 50 Hz.
The circuits of the contactor are designed for a rated insulation voltage of 1000 V (main circuit) and 690 V (signal circuit) according to IEC 60947. Overvoltage category III and pollution degree 3 indicate a robust construction suitable for use in contaminated or industrial environments. The rated impulse voltage withstand is 8 kV. The conventional thermal current rating is 125 A for the main circuit and 10 A for the signal circuit at 60 °C. The rated breaking capacity is 1100 A at 440 V, highlighting the contactor’s ability to interrupt high short-circuit currents.
The contactor is compatible with a variety of accessories that extend its functionality. These include auxiliary switch blocks such as the LADN40 (4 closing contacts) or LADN22 (2 closing + 2 opening contacts), which are mounted front-side with screw terminals. For time-delayed functions, time blocks such as the LADR2 (release-delayed, 1–30 s) or LADT2 (pickup-delayed, 0.1–30 s) are available. Additionally, control modules such as LA4DA2E (RC circuit) or LA4DE2E (varistor) are available for the coil to optimize switching operations. Compatibility is ensured by the compatibility code LC1D.
Mounting is done via Everlink plug connections and spring clamps, ensuring a secure and long-lasting electrical connection. The tightening torques are 12 Nm for main circuit connectors (with flat screwdriver Ø 6–8 mm or hexagonal screw head 4 mm) and 1.2 Nm for control circuit screw terminals (with flat screwdriver Ø 6 mm or Phillips No. 2). Dimensions are 85 mm (width) × 127 mm (height) × 130 mm (depth). Installation requires adherence to specified torques, especially for cable cross-sections over 35 mm², to ensure contact quality.
The contactor offers a high mechanical life of 10 million switching cycles and an electrical life of 1.5 million cycles at 80 A and AC-3 duty. The safety cover protects against unintended access to moving parts. The mechanically coupled contacts and mirror contacts enable use in safety applications according to EN/ISO 13849-1, with a safety level B10d of 20 million cycles under mechanical load. Certifications according to UL, CSA, CCC, EAC, LROS, DNV-GL, RINA, and BV confirm worldwide suitability for various industries and regions.