Schneider Electric LC1D80AP7, EAN: 3606481312174

Schneider Electric LC1D80AP7 contactor 3p+1S+1Ö 80A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D80AP7 contactor 3p+1S+1Ö 80A

Lieske Part No. 1599154
Mfg Part No LC1D80AP7
EAN-Code 3606481312174
Manufacturer Schneider Electric
Here only 438,75 EUR
522,11 EUR incl. VAT

Further information for Schneider Electric LC1D80AP7 contactor 3p+1S+1Ö 80A

Complementary
Motor power kW22 kW at 220/230 V AC 50/60 Hz (AC-3); 37 kW at 380/400 V AC 50/60 Hz (AC-3); 37 kW at 415 V AC 50/60 Hz (AC-3); 37 kW at 440 V AC 50/60 Hz (AC-3); 37 kW at 500 V AC 50/60 Hz (AC-3); 37 kW at 660/690 V AC 50/60 Hz (AC-3); 22 kW at 220/230 V AC 50/60 Hz (AC-3e); 37 kW at 380/400 V AC 50/60 Hz (AC-3e); 37 kW at 415 V AC 50/60 Hz (AC-3e); 37 kW at 440 V AC 50/60 Hz (AC-3e); 37 kW at 500 V AC 50/60 Hz (AC-3e); 37 kW at 660/690 V AC 50/60 Hz (AC-3e)
Motor power hp5 hp at 115 V AC 60 Hz for 1 phase motors; 10 hp at 230/240 V AC 60 Hz for 1 phase motors; 20 hp at 200/208 V AC 60 Hz for 3 phases motors; 20 hp at 230/240 V AC 60 Hz for 3 phases motors; 40 hp at 460/480 V AC 60 Hz for 3 phases motors; 50 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 80 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1000 A at 440 V AC for power circuit conforming to IEC 60947
Rated breaking capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current640 A 40 °C - 10 s for power circuit; 900 A 40 °C - 1 s for power circuit; 110 A 40 °C - 10 min for power circuit; 260 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 125 A gG at
Average impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e
[Ui] rated insulation voltageSignalling circuit: 690 V conforming to IEC 60947-1; Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability0.7 Mcycles 80 A AC-1 at Ue
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz
Operating time4...19 ms opening; 12...26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product certificationsCCC; CSA; EAC; UL; KC; DNV-GL; LROS (Lloyds register of shipping)
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width55 mm
Depth120 mm
Net weight0.86 kg
Logistical informations
Country of originID
Main
RangeTeSys; TeSys Deca
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit: 690 V AC 25...400 Hz; Power circuit: 300 V DC
[Ie] rated operational current80 A (at
[Uc] control circuit voltage230 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.200 cm
Package 1 Width13.500 cm
Package 1 Length15.500 cm
Package 1 Weight927.000 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.781 kg
The LC1D80AP7 contactor from the TeSys Deca series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads. It features a rated operational current of 80 A and is designed for use categories AC-1, AC-3, and AC-3e, supporting a motor power of 37 kW at 400 V AC-3. The control circuit voltage is 230 V AC at 50/60 Hz, making it suitable for standard industrial networks. The device is designed without an integrated wiring module, enabling flexible integration into existing control systems.

Applications
This contactor is designed for controlling electric drives in industrial plants, particularly in applications with medium to high loads, such as in manufacturing, packaging technology, or conveyor system control. The AC-3e use category allows operation under special drive conditions, such as those found in crane systems or pumps. The rated insulation voltage of 690 V and overvoltage category III make it suitable for installations with increased electrical stress.

Functions and Equipment in Detail
The device features 3 normally closed contacts in the main circuit and an additional auxiliary switch block with 1 normally closed and 1 normally open contact, which can be used for signaling functions in control systems. The contacts are mechanically coupled and equipped with mirror contacts, enhancing reliability in safety applications. Spring terminals and Everlink technology ensure a secure and long-lasting electrical connection, remaining stable even under high operational loads. The maximum operating rate is 3600 switching operations per hour at 60 °C, enabling high dynamic performance during operation.

Technology Explained Simply
The contactor is rated for an operating voltage of 690 V AC in the main circuit and 300 V DC. The rated impulse voltage withstand is 6 kV, ensuring high electrical stability during transient voltage surges. The conventional thermal current rating (Ith) is 80 A in the main circuit at 60 °C, defining the thermal load capacity under real operating conditions. The electrical life is 0.7 million switching cycles at 80 A AC-1, while the mechanical life is 6 million cycles. The operating time is 4–19 ms for opening and 12–26 ms for closing, enabling fast response to control signals.

Compatibility and Accessories
The contactor is compatible with various accessory modules, including delayed auxiliary switch blocks (e.g. LAD-R4, LADR2, LADR0), time blocks (e.g. LADT0, LADT2), auxiliary switch blocks (e.g. LADN31, LADN40, LADN20), and interlocking blocks (e.g. LAD6K10M). These modules extend the functionality of the contactor for specific applications, such as time delays, mechanical interlocks, or additional signal contacts. The coil technology without an integrated wiring module allows flexible adaptation to existing circuit diagrams.

Mounting and Installation
Mounting is performed in standard control panels using screws or mounting rails. Dimensions are 55 mm (width) × 122 mm (height) × 120 mm (depth), allowing it to fit in typical enclosures. Wiring is done via spring terminals, ensuring a secure and durable connection. Installation and maintenance must only be carried out by qualified personnel, as specified in the manufacturer’s instructions.

Operational Advantages
The contactor offers high operational safety through mechanically coupled contacts and mirror contacts, increasing reliability in critical applications. The high electrical and mechanical life, along with fast operating time, ensure efficient and low-maintenance operation. Certifications according to CCC, CSA, EAC, UL, KC, DNV-GL, and LROS (Lloyds Register of Shipping) confirm suitability for international applications, including marine environments. The heat dissipation is 4–5 W at 50/60 Hz, minimizing thermal load in the enclosure.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1599154
qrcode für Schneider Electric LC1D80AP7 contactor 3p+1S+1Ö 80A