| Additional features |
| Motor power (kW) | 18.5 kW at 220/230 V AC 50/60 Hz (AC-3); 37 kW at 380/400 V AC 50/60 Hz (AC-3); 37 kW at 415 V AC 50/60 Hz (AC-3); 37 kW at 440 V AC 50/60 Hz (AC-3); 37 kW at 500 V AC 50/60 Hz (AC-3); 37 kW at 660/690 V AC 50/60 Hz (AC-3) |
| Compatibility code | LC1D |
| Pole contact composition | 3 S |
| Safety cover | With |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for signal circuit; 80 A (at 60 °C) for power circuit |
| [Irms] Rated making capacity | 140 A AC for signal circuit conforming to IEC 60947-5-1; 250 A DC for signal circuit conforming to IEC 60947-5-1; 1000 A at 440 V AC for circuit conforming to IEC 60947 |
| Rated breaking capacity | 1000 A at 440 V for circuit, corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 520 A 40 °C - 10 s for circuit; 900 A 40 °C - 1 s for circuit; 110 A 40 °C - 10 min for circuit; 260 A 40 °C - 1 min for circuit; 100 A - 1 s for signal circuit; 120 A - 500 ms for signal circuit; 140 A - 100 ms for signal circuit |
| Associated fuse | 10 A gG for signal circuit in accordance with IEC 60947-5-1; 125 A gG at |
| Average impedance | 1.5 MOhm - Ith 80 A 50 Hz for circuit |
| Power dissipation per pole | 9,6 W AC-1; 6,3 W AC-3; 6,3 W AC-3e |
| [Ui] Rated insulation voltage | Signal circuit: 690 V corresponds to IEC 60947-1; Power circuit: 690 V corresponds to IEC 60947-4-1 |
| Over voltage category | III |
| Pollution degree | 3 |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947 |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 6 Mcycles |
| Electrical lifetime | 0.7 Mcycles 80 A AC-1 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without integrated switching module |
| Control circuit voltage limits | 0.3 - 0.6 Uc (-40…70 °C): drop-out voltage AC 50/60 Hz; 0.8 - 1.1 Uc (-40…60 °C): operation AC 50 Hz; 0.85 - 1.1 Uc (-40…60 °C): operation AC 60 Hz; 1 - 1.1 Uc (60…70 °C): operation AC 50/60 Hz |
| Input power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat emission | 4…5 W at 50/60 Hz |
| Operating time | 4 - 19 ms opening; 12 - 26 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening moment | Power circuit: 8 Nm - on EverLink BTR screw-in connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 Nm - on EverLink BTR screw-in connectors - cable 1…25 mm² hexagonal screw head 4 mm; Control circuit: 1.7 Nm - on screw terminals - with screwdriver size No. 2; Power circuit: 2.5 Nm - on screw terminals - with screwdriver size No. 2 |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching voltage | 17 V for signal circuit |
| Min. switching current | 5 mA for signal circuit |
| Insulation resistance | > 10 MΩ for signal circuits |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Mounting bracket | Plate; rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys; TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Application of contactor | Motor control; resistive load |
| Application category | AC-3; AC-3e; AC-1; AC-4 |
| Pole description | 3P |
| [Ue] Rated operational voltage | Circuit: 690 V AC 25 - 400 Hz; Circuit: 300 V DC |
| [Ie] rated operational current | 80 A (at |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz |
| Mounting |
| Standards | EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No. 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2 |
| Product certifications | CCC; CSA; EAC; UL; KC; DNV-GL; LROS (Lloyds register of shipping) |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Protection treatment | TH corresponds to IEC 60068-2-30 |
| Climate resistance | Complies with IACS E10 damp heat exposure; complies with IEC 60947-1 Annex Q Category D damp heat exposure |
| Device ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contact open (2 Gn, 5 - 300 Hz); vibrations contact closed (4 Gn, 5 - 300 Hz); shocks contact closed (15 Gn for 11 ms); shocks contact open (10 Gn for 11 ms) |
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |
| Product weight | 0,86 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 6,2 cm |
| VPE 1 width | 14 cm |
| VPE 1 length | 15,5 cm |
| Packaging weight (Lbs) | 850 g |
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact + 1 NC contact, rated operating power at AC-3, 400 V 37 kW, rated operating current Ie at AC-3, 400 V 80 A, coil 48 V AC. Dimensions (WxHxD) 55x122x120 mm, weight 0.86 kg. Category AC-3, AC-1. without integrated circuit module. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications thanks to mechanically coupled contacts and mirror contacts. Certifications according to CCC, CSA, EAC, UL, KC, DNV-GL, LROS (Lloyds register of shipping). Product standards in accordance with.