Complementary
Motor power kW15 kW at 220/230 V AC 50/60 Hz (AC-3); 22 kW at 380/400 V AC 50/60 Hz (AC-3); 25 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 30 kW at 500 V AC 50/60 Hz (AC-3); 33 kW at 660/690 V AC 50/60 Hz (AC-3); 15 kW at 220/230 V AC 50/60 Hz (AC-3e); 22 kW at 380/400 V AC 50/60 Hz (AC-3e); 25 kW at 415 V AC 50/60 Hz (AC-3e); 30 kW at 440 V AC 50/60 Hz (AC-3e); 30 kW at 500 V AC 50/60 Hz (AC-3e); 33 kW at 660/690 V AC 50/60 Hz (AC-3e); 11 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp3 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 80 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity900 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current400 A 40 °C - 10 s for power circuit; 810 A 40 °C - 1 s for power circuit; 84 A 40 °C - 10 min for power circuit; 208 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 100 A gG at
Average impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.45 Mcycles 50 A AC-3 at Ue
Control circuit typeAC at 60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 60 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 60 Hz
Operating time4...19 ms opening; 12...26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportRail; Plate
Contractual warranty
Warranty (in months)18
Environment
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product certificationsCCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width55 mm
Depth120 mm
Net weight0.855 kg
Logistical informations
Country of originID
Main
RangeTeSys; TeSys Deca
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current50 A (at
[Uc] control circuit voltage120 V AC 60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6 cm
Package 1 Width13.5 cm
Package 1 Length15.5 cm
Package 1 Weight939 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight9.64 kg
Unit Type of Package 3P12
Number of Units in Package 3160
Package 3 Height45 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight166.24 kg
TeSys LC1D power contactor. 3 pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 22 kW, rated operating current Ie at AC-3, 400 V 50 A, coil 120 V AC. Dimensions (WxHxD) 55x122x120 mm, weight 0.855 kg. It includes a 120V 50/60Hz AC coil and 1 NC + 1 NO built-in auxiliary contacts and can be used in safety applications thanks to its certified NO mirror contact. Category AC-1, AC-4, AC-3. without integrated wiring module. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to DNV, GOST, UL, LROS (Lloyds register of shipping), GL, RINA, BV, CSA, CCC.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1565080
qrcode für Schneider Electric LC1D50AG7 contactor 3p 50A