Schneider Electric LC1D50A6F7, EAN: 3389119408912

Schneider Electric LC1D50A6F7 contactor 3p 50A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D50A6F7 contactor 3p 50A

Lieske Part No. 766755
Mfg Part No LC1D50A6F7
EAN-Code 3389119408912
Manufacturer Schneider Electric
Here only 256,59 EUR
305,34 EUR incl. VAT

Further information for Schneider Electric LC1D50A6F7 contactor 3p 50A

Complementary
Motor power kW15 kW at 220/230 V AC 50/60 Hz (AC-3); 22 kW at 380/400 V AC 50/60 Hz (AC-3); 25 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 30 kW at 500 V AC 50/60 Hz (AC-3); 33 kW at 660/690 V AC 50/60 Hz (AC-3); 15 kW at 220/230 V AC 50/60 Hz (AC-3e); 22 kW at 380/400 V AC 50/60 Hz (AC-3e); 25 kW at 415 V AC 50/60 Hz (AC-3e); 30 kW at 440 V AC 50/60 Hz (AC-3e); 30 kW at 500 V AC 50/60 Hz (AC-3e); 33 kW at 660/690 V AC 50/60 Hz (AC-3e); 11 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp3 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 80 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity900 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current400 A 40 °C - 10 s for power circuit; 810 A 40 °C - 1 s for power circuit; 84 A 40 °C - 10 min for power circuit; 208 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 100 A gG at
Average impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.45 Mcycles 50 A AC-3 at Ue
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz
Operating time4...19 ms opening; 12...26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections - terminalsControl circuit: lugs-ring terminals - external diameter: 8 mm; Power circuit: lugs-ring terminals - external diameter: 16.5 mm
Tightening torqueControl circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5; Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5; Power circuit: 6 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2; Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportRail; Plate
Contractual warranty
Warranty (in months)18
Environment
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product certificationsCCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width55 mm
Depth120 mm
Net weight0.855 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current50 A (at
[Uc] control circuit voltage110 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.0 cm
Package 1 Width14.0 cm
Package 1 Length15.0 cm
Package 1 Weight850.0 g
The LC1D50A6F7 contactor from the TeSys Deca series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It features a rated operational current of 50 A and is designed for use categories AC-1, AC-3, AC-3e, and AC-4, supporting a motor power of 22 kW at 400 V AC-3. The control circuit voltage is 110 V AC at 50/60 Hz. The device is equipped with an additional auxiliary contact arrangement consisting of one normally closed (NC) and one normally open (NO) contact, making it suitable for complex control logic. The contacts are mechanically coupled and feature mirror contacts, enhancing suitability for safety applications.

Applications
This contactor is designed for use in industrial plants where reliable and safe switching functions for motors and resistive loads are required. It is used in manufacturing plants, process engineering, and machine building, where high switching cycles and mechanical stresses occur. The use categories AC-3 and AC-3e make it particularly suitable for operating three-phase motors, while AC-4 is intended for applications with high inrush currents, such as crane systems or presses.

Functions and Equipment in Detail
The device features coil technology without an integrated wiring module, enabling simple mounting and maintenance. The contacts are equipped with Everlink technology and spring terminals, ensuring a secure and long-lasting electrical connection. The auxiliary contacts are instantaneous and allow integration into control and monitoring systems. The mechanical life expectancy is 6 million switching cycles, while the electrical life expectancy at 50 A AC-3 is 1.45 million switching cycles. The rated insulation voltage for the circuit is 690 V according to IEC 60947-4-1, and the impulse voltage withstand is 6 kV.

Technology Explained Simply
The contactor coil is supplied with 110 V AC, enabling magnetic attraction of the contacts once the control circuit is activated. The operating voltage variation ranges from 0.8 to 1.1 times the nominal voltage at temperatures from -40 to 60 °C, ensuring stable performance under variable conditions. The pickup power is 160 VA at 50 Hz, and the holding power is 15 VA. The rated breaking capacity is 900 A at 440 V, highlighting the contactor’s ability to safely interrupt short-circuit currents. The overvoltage category III and pollution degree 3 indicate suitability for industrial environments with high electrical and mechanical stresses.

Compatibility and Accessories
The contactor is compatible with various accessories, including auxiliary switch blocks such as LADN316 (3NO1NC), LADN046 (4NC), LAD8N206 (2NO), and LADN226 (2NO2NC), enabling expansion of control functions. Additionally, time delay blocks such as LADT26 (delayed pickup) or LADT46 (delayed release) and wiring modules such as LAD4RC3G or RC element LAD4RC3U can be integrated. For motor protection, the GV3L50 motor protection switch 3p 50A is suitable. The mechanical interlock LAD4CM enables safe combination with other contactors.

Mounting and Installation
The contactor is designed for mounting on a 35 mm DIN rail (EN 50022) and can be screwed onto metal plates, especially in applications with vibrations exceeding 3g. Dimensions are 55 mm (width) × 122 mm (height) × 120 mm (depth), and the net weight is 0.855 kg. Cable connections are made via Everlink spring terminals, ensuring a secure connection even under high switching cycles. Installation is performed by simply clipping the device onto the rail and wiring the main and auxiliary contacts.

Operational Advantages
The contactor offers high reliability through mechanically coupled contacts and mirror contacts, ensuring safe switching functions even in critical applications. The Everlink technology ensures a long-lasting and maintenance-friendly electrical connection. The high life expectancy and suitability for various use categories make it a universally applicable component in industrial electrical engineering. Certifications according to GOST, DNV, RINA, CSA, CCC, UL, LROS, BV, and GL underscore the international acceptance and safety of the product.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/766755
qrcode für Schneider Electric LC1D50A6F7 contactor 3p 50A