| Complementary |
| Motor power kW | 11 kW at 220/230 V AC 50/60 Hz (AC-3); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3); 22 kW at 415/440 V AC 50/60 Hz (AC-3); 22 kW at 500 V AC 50/60 Hz (AC-3); 30 kW at 660/690 V AC 50/60 Hz (AC-3); 11 kW at 220/230 V AC 50/60 Hz (AC-3e); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 22 kW at 415/440 V AC 50/60 Hz (AC-3e); 22 kW at 500 V AC 50/60 Hz (AC-3e); 30 kW at 660/690 V AC 50/60 Hz (AC-3e); 9 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 3 hp at 115 V AC 50/60 Hz for 1 phase motors; 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 800 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 320 A 40 °C - 10 s for power circuit; 720 A 40 °C - 1 s for power circuit; 72 A 40 °C - 10 min for power circuit; 165 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 80 A gG at |
| Average impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole | 2.4 W AC-3; 5.4 W AC-1; 2.4 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 6 Mcycles |
| Electrical durability | 1.4 Mcycles 60 A AC-1 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 4…5 W at 50/60 Hz |
| Operating time | 4...19 ms opening; 12...26 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2 |
| Product certifications | CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms) |
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |
| Net weight | 0.85 kg |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range | TeSys; TeSys Deca |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 60 A (at |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.300 cm |
| Package 1 Width | 13.500 cm |
| Package 1 Length | 15.200 cm |
| Package 1 Weight | 940.700 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.300 kg |
The LC1D40AF7 contactor from the TeSys Deca series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads. It features a main contact configuration of 3 closers and integrated auxiliary contacts in the configuration of 1 closer + 1 opener. The coil is designed for a control circuit voltage of 110 V AC at 50/60 Hz, making it suitable for standard applications in industrial and commercial electrical installations. The device is certified for use categories AC-1, AC-3, AC-3e, and AC-4, with category AC-3 representing the typical application for motor control.
The contactor is designed for controlling electric motors across various voltage ranges. At an operating voltage of 380/400 V AC and use category AC-3, the rated operational power is 18.5 kW. In other voltage ranges, motor powers range from 9 kW (at AC-4, 400 V) to 30 kW (at 660/690 V, AC-3). The rated operational currents vary depending on the application category and voltage; at AC-3 and 400 V, the operational rated current is 40 A. The application includes both control of three-phase motors and resistive loads in industrial installations.
The contactor features a safety cover that enables secure mounting and maintenance. The contacts are mechanically interlocked and equipped with mirror contacts, enhancing reliability in safety applications. Current connections are made via Everlink technology and spring terminals, ensuring quick and secure installation. The auxiliary contacts are arranged on the front side, allowing easy integration into control circuits. The device is supplied without an integrated wiring module, enabling flexible adaptation to existing circuits.
The contactor coil is supplied with 110 V AC and operates at frequencies of 50/60 Hz. The coil’s operating voltage range is between 0.8 and 1.1 times the nominal voltage at temperatures from -40 to 60 °C. The pickup power is 160 VA at 50 Hz and 140 VA at 60 Hz, while the holding power is 15 VA at 50 Hz and 13 VA at 60 Hz. Heat dissipation is between 4 and 5 W at 50/60 Hz. The rated insulation voltage is 690 V for the power circuit according to IEC 60947-4-1 and 600 V for the signal circuit according to UL/CSA. Overvoltage category III and pollution degree 3 indicate use in industrial environments. The rated impulse voltage withstand is 6 kV.
The contactor is compatible with various accessories that extend its functionality. These include auxiliary switch blocks such as the LADN40 (4S non-delayed) or LADN22 (2S+2O non-delayed), time blocks such as the LADT0 (pickup delayed 0.10–3.00 s) or LADT4 (pickup delayed 10.00–180.00 s), and interlocking blocks such as the LAD6K10F. RC elements such as the LAD4RC3U (110–240 V) or LAD4RC3G (50–127 VAC) can be used to dampen switching surges. The reversing contactor combination LAD9R3 enables reversal of motor rotation. The busbar GV3G264 (64 mm, 110 A) is suitable for parallel feeding of two contactors.
Mounting is done via standard screw terminals. Dimensions are 55 mm (width) × 122 mm (height) × 120 mm (depth). Weight is 0.85 kg. Spring terminals and Everlink technology enable quick and secure connections. The safety cover protects against unintended access and facilitates maintenance. Installation is carried out in enclosures or control systems meeting the requirements of overvoltage category III and pollution degree 3.
The contactor offers a high mechanical life of 6 million switching cycles and an electrical life of 1.4 million switching cycles at 60 A AC-1. The rated short-time current withstand is 320 A for 10 seconds and 720 A for 1 second for the power circuit. The rated breaking capacity is 800 A at 440 V. Power loss per pole is 2.4 W (AC-3) and 5.4 W (AC-1). Certifications according to CCC, CSA, GOST, and UL ensure compliance with international safety and quality standards. Mechanically interlocked contacts and mirror contacts enhance reliability in safety-critical applications.