| Complementary |
| Motor power kW | 11 kW at 220/230 V AC 50/60 Hz (AC-3); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3); 22 kW at 415/440 V AC 50/60 Hz (AC-3); 22 kW at 500 V AC 50/60 Hz (AC-3); 30 kW at 660/690 V AC 50/60 Hz (AC-3); 11 kW at 220/230 V AC 50/60 Hz (AC-3e); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 22 kW at 415/440 V AC 50/60 Hz (AC-3e); 22 kW at 500 V AC 50/60 Hz (AC-3e); 30 kW at 660/690 V AC 50/60 Hz (AC-3e); 9 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 3 hp at 115 V AC 50/60 Hz for 1 phase motors; 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 800 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 320 A 40 °C - 10 s for power circuit; 720 A 40 °C - 1 s for power circuit; 72 A 40 °C - 10 min for power circuit; 165 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 80 A gG at |
| Average impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole | 2.4 W AC-3; 5.4 W AC-1; 2.4 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 6 Mcycles |
| Electrical durability | 1.4 Mcycles 60 A AC-1 at Ue |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 4…5 W at 50/60 Hz |
| Operating time | 4...19 ms opening; 12...26 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque | Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 0.75…25 mm² hexagonal screw head 4 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2; Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2 |
| Product certifications | CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms) |
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |
| Net weight | 0.85 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 60 A (at |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.300 cm |
| Package 1 Width | 13.800 cm |
| Package 1 Length | 15.400 cm |
| Package 1 Weight | 908.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.915 kg |
The LC1D40A3B7 contactor from the TeSys Deca series by Schneider Electric is a 3-pole contactor for motor control and operation with resistive loads. It features three main contacts (3P) and additional auxiliary contacts configured as 1 NO + 1 NC. The control circuit voltage is 24 V AC at 50/60 Hz, making it suitable for applications with standard AC power supply. The device is designed for use categories AC-1, AC-3, AC-3e, and AC-4, with category AC-3 representing the typical application for controlling electric motors. At an operating voltage of 400 V AC and category AC-3, the rated operational power is 18.5 kW and the rated operational current Ie is 40 A. The maximum motor power at 660/690 V AC-3 is 30 kW, highlighting its suitability for industrial applications with higher voltages.
This contactor is primarily designed for controlling electric motors in industrial plants, particularly in drive technology, conveyor systems, pump and fan installations. Category AC-4 allows use under heavy starting conditions, such as those found in crane systems or presses. Operation with resistive loads, such as heaters or resistance-based applications, is also intended. Certifications according to CCC, UL, GOST, and CSA ensure compliance with international safety and quality standards, guaranteeing suitability for various markets.
The contactor includes a safety cover enabling protected operation. The main contacts are configured as 3 NO, ensuring a secure electrical connection. The auxiliary contacts (1S+1Oe) are used for signal transmission in control and monitoring systems. The contacts are mechanically interlocked and feature mirror contacts, enhancing reliability in safety applications. Electrical connections are made via Everlink and spring terminals, enabling quick and secure installation.
The rated insulation voltage is 690 V for the circuit according to IEC 60947-4-1, ensuring high electrical safety. The overvoltage category III and pollution degree 3 indicate suitability for industrial environments with high stress. The rated impulse voltage withstand is 6 kV, protecting the device against transient voltage surges. The mechanical life is 6 million switching cycles, while the electrical life at 60 A AC-1 is 1.4 million cycles. The power loss per pole is 2.4 W at AC-3, indicating efficient heat dissipation. Heat dissipation ranges from 4 to 5 W at 50/60 Hz. The operating time is 4 to 19 ms for opening.
The contactor is compatible with various accessories, including time delay blocks such as LAD9ET1S, LADT03, or LADT23, which can be used for delayed switching operations. Mechanical interlocks such as LAD4CM or interlock blocks like LAD6K10B enable safe combination with other contactors. Motor protection circuit breakers such as GV3G264 or GV3P40 can be used for additional protection functions. Wiring modules such as LAD4RC3E or adapter sets like LA4DBL are also available to adapt control characteristics.
Mounting is done via Everlink and spring terminals, enabling quick and secure connections. Dimensions are 55 mm (width) × 122 mm (height) × 120 mm (depth), allowing installation in standard control panels. Weight is 0.85 kg. Installation and maintenance must only be performed by qualified personnel, as specified in the manufacturer’s instructions.
The contactor offers high operational safety due to mechanically interlocked contacts and mirror contacts, which is particularly beneficial in safety applications. The long service life and robust construction ensure reliable performance throughout the entire service period. Compatibility with various accessories allows flexible adaptation to different requirements. Certifications according to international standards ensure compliance with safety and quality requirements in various markets. The control circuit voltage of 24 V AC is a standard value used in many industrial control systems, facilitating integration into existing systems.