Complementary
Motor power kW9 kW at 220/230 V AC 50/60 Hz (AC-3); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3); 18.5 kW at 415/440 V AC 50/60 Hz (AC-3); 18.5 kW at 500 V AC 50/60 Hz (AC-3); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3); 9 kW at 220/230 V AC 50/60 Hz (AC-3e); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 18.5 kW at 415/440 V AC 50/60 Hz (AC-3e); 18.5 kW at 500 V AC 50/60 Hz (AC-3e); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 7.5 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 5 hp at 240 V AC 50/60 Hz for 1 phase motors; 20 hp at 480 V AC 50/60 Hz for 3 phases motors; 25 hp at 600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 50 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current60 A 40 °C - 10 min for power circuit; 430 A 40 °C - 1 s for power circuit; 150 A 40 °C - 1 min for power circuit; 310 A 40 °C - 10 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at
Average impedance2 mOhm - Ith 50 A 50 Hz for power circuit
Power dissipation per pole5 W AC-1; 3 W AC-3; 3 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.4 Mcycles 50 A AC-1 at Ue
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time4...19 ms opening; 12...22 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms)
Height85 mm
Width45 mm
Depth92 mm
Net weight0.38 kg
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current50 A (at
[Uc] control circuit voltage230 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width9.200 cm
Package 1 Length11.200 cm
Package 1 Weight414.000 g
Unit Type of Package 2S02
Number of Units in Package 220
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.500 kg
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight142.500 kg
3-pole contactors LC
D-Control voltage 23 V 5/6 Hz - The contactors provide basically two integrated auxiliary switches:
S +
NC - Connection type: Screw Motor rating AC-3:
8.5 kW Type: LCD
-D38P7 item:
ST.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/703445
qrcode für Schneider Electric LC1D38P7 Contactor 3p 38 A