| Complementary |
| Motor power kW | 7.5 kW at 220/230 V AC 50/60 Hz (AC-3); 15 kW at 380/400 V AC 50/60 Hz (AC-3); 15 kW at 415/440 V AC 50/60 Hz (AC-3); 18.5 kW at 500 V AC 50/60 Hz (AC-3); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3); 7.5 kW at 220/230 V AC 50/60 Hz (AC-3e); 15 kW at 380/400 V AC 50/60 Hz (AC-3e); 15 kW at 415/440 V AC 50/60 Hz (AC-3e); 18.5 kW at 500 V AC 50/60 Hz (AC-3e); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 7.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 25 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 50 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 550 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 550 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit; 430 A 40 °C - 1 s for power circuit; 60 A 40 °C - 10 min for power circuit; 138 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at |
| Average impedance | 2 mOhm - Ith 50 A 50 Hz for power circuit |
| Power dissipation per pole | 2 W AC-3; 5 W AC-1; 2 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.65 Mcycles 32 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing; 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms) |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 92 mm |
| Net weight | 0.375 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 32 A (at |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 9.200 cm |
| Package 1 Length | 11.200 cm |
| Package 1 Weight | 404.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.354 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 160 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 76.016 kg |
The LC1D32M7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It features a rated operational current of 32 A at AC-3 and is designed for a control circuit voltage of 220 V AC 50/60 Hz. The device is designed for use in industrial installations where reliable and safe switching performance is required. The integrated safety cover ensures protected operation and prevents unintended contact. The contact configuration includes 3 normally closed contacts in the main circuit, along with additional auxiliary contacts in the configuration of 1 normally closed + 1 normally open, which can be used for control and monitoring tasks.
Applications
The contactor is suitable for various application categories, including AC-1 (resistive load), AC-3 (motor start and stop), AC-3e (motor start with high load), and AC-4 (frequent starts and stops). At an operating voltage of 400 V AC and category AC-3, the motor rated power is 15 kW. Applications range from simple motor controls to complex systems in manufacturing industries, where high switching cycles and mechanical stresses occur. Certifications according to DNV, RINA, LROS, CCC, CSA, GL, GOST, BV, and UL confirm suitability for international applications, including marine and heavy industrial installations.
Functions and Equipment in Detail
The contactor features coil technology without an integrated wiring module, enabling simple installation and maintenance. The contacts are mechanically coupled and equipped with mirror contacts, enhancing reliability in safety applications. Current connections are made via Everlink technology and spring terminals, ensuring a secure and long-lasting connection. The auxiliary contacts are instantaneous and can be used for signals, feedback, or interlocks in control systems. The operating time is 1 second, which is sufficient for most industrial applications.
Technology Explained Simply
The rated insulation voltage is 690 V for the circuit and complies with IEC 60947-4-1 standards, with UL and CSA certifications also available for 600 V. The overvoltage category III and pollution degree 3 indicate suitability for industrial environments with increased electrical stress and contamination risk. The rated impulse voltage withstand is 6 kV, protecting the device against transient voltage spikes. The thermal withstand capacity is 50 A in the circuit at 60 °C, ensuring high thermal stability. The power loss per pole is 2 W for AC-3 and AC-3e, indicating efficient heat dissipation.
Compatibility and Accessories
The contactor is compatible with various accessories, including auxiliary switch blocks such as LADN20, LADN04, LAD8N11, LADN22, LADN02, and LAD8N20, which enable additional switching functions depending on requirements. Time delay blocks such as LADT0 and LADT2 offer delayed switching operations, with LADT0 providing a delay of 0.10–3.00 seconds and LADT2 of 0.10–30.00 seconds. For motor protection, relays such as LRD32 or GV2ME32 are available, providing overload protection. Interlocking blocks such as LAD6K10M and locking devices such as LAD9V2 support mechanical interlocking in complex control systems. The three-phase busbar system GV2G445 and GV2G245 enable flexible integration into distribution systems.
Mounting and Installation
Mounting is done via screw connection or spring terminals, with Everlink technology ensuring quick and secure connections. Dimensions are 45 mm (width) × 85 mm (height) × 92 mm (depth), allowing compact placement in enclosures. The weight of 0.375 kg is relevant for mounting planning. The control circuit voltage limits are 0.3–0.6 Uc for release and 0.8–1.1 Uc for operation, with exact values depending on frequency (50/60 Hz) and temperature (-40…70 °C). The pickup power is 70 VA at 50/60 Hz, and the holding power is 7–7.5 VA, ensuring efficient energy use.
Operational Advantages
The mechanical life is 15 million switching cycles, and the electrical life is 1.65 million cycles at 32 A AC-3 and rated voltage. The rated short-time current withstand is 260 A for 10 seconds and 430 A for 1 second in the circuit, demonstrating high load capacity. The rated breaking capacity is 550 A at 440 V, meeting the requirements of IEC 60947. The safety level B10d = 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load according to EN/ISO 13849-1 makes the device suitable for safety-critical applications. Heat dissipation is 2–3 W, enabling efficient cooling in enclosed enclosures. Certifications and compliance with international standards ensure worldwide usability across various industries.