| Complementary |
| Motor power kW | 7.5 kW at 220/230 V AC 50/60 Hz (AC-3); 15 kW at 380/400 V AC 50/60 Hz (AC-3); 15 kW at 415/440 V AC 50/60 Hz (AC-3); 18.5 kW at 500 V AC 50/60 Hz (AC-3); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3); 7.5 kW at 220/230 V AC 50/60 Hz (AC-3e); 15 kW at 380/400 V AC 50/60 Hz (AC-3e); 15 kW at 415/440 V AC 50/60 Hz (AC-3e); 18.5 kW at 500 V AC 50/60 Hz (AC-3e); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 7.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 25 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 50 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 550 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 550 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit; 430 A 40 °C - 1 s for power circuit; 60 A 40 °C - 10 min for power circuit; 138 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at |
| Average impedance | 2 mOhm - Ith 50 A 50 Hz for power circuit |
| Power dissipation per pole | 2 W AC-3; 5 W AC-1; 2 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 1.65 Mcycles 32 A AC-3 at Ue |
| Control circuit type | DC standard |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC |
| Inrush power in W | 5.4 W (at 20 °C) |
| Hold-in power consumption in W | 5.4 W at 20 °C |
| Operating time | 63 ±15 % ms closing; 20 ±20 % ms opening |
| Time constant | 28 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms) |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 101 mm |
| Net weight | 0.535 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 32 A (at |
| [Uc] control circuit voltage | 24 V DC |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 9.200 cm |
| Package 1 Length | 11.200 cm |
| Package 1 Weight | 585.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.055 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 240 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 154.500 kg |
The LC1D32BD contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It is designed for use in industrial plants where reliable and safe switching functions are required under high loads. The device has a rated operational current of 32 A and is designed for a control circuit voltage of 24 V DC. The rated operational power is 15 kW at 400 V AC in usage category AC-3, making it suitable for controlling three-phase motors. The integrated bidirectional amplitude-limiting diode protects the coil from voltage spikes and increases the device's service life.
Applications
The contactor is intended for various usage categories, including AC-1 (resistive load), AC-3 (motor start and stop), AC-3e (motor start and stop with increased load), and AC-4 (frequent starts and stops). It is therefore suitable for applications in the manufacturing industry, packaging industry, material handling technology, and other areas where motors or resistive loads need to be controlled. Certifications according to DNV, GL, CCC, UL, GOST, BV, LROS, RINA, and CSA confirm its suitability for international requirements, particularly in shipping and machinery construction.
Functions and Equipment in Detail
The device features 3 closed contacts in the main current circuit and additional auxiliary contacts in the configuration of 1 closed + 1 open contact. These auxiliary contacts enable integration into complex control systems, e.g., for feedback of switching states or interlocking with other contactors. The mechanically coupled contacts and mirror contacts ensure a safe and reliable switching function, especially in safety-critical applications. The spring clamps and Everlink technology ensure a secure and long-lasting current connection that remains stable even under high mechanical loads.
Technology Explained Simply
The contactor coil is operated at 24 V DC, which is a common voltage in industrial controls. The operating voltage fluctuations range from 0.7 to 1.25 times the nominal voltage at temperatures from -40 °C to 60 °C. The pickup power is 5.4 W at 20 °C, as is the holding power consumption. The operating time is 63 ± 15 % ms for closing and 20 ± 20 % ms for opening. The time constant is 28 ms. The electrical service life is 1.65 million switching cycles at 32 A and AC-3 operation, while the mechanical service life is 30 million cycles. The rated breaking capacity is 550 A at 440 V, highlighting the contactor's ability to safely interrupt short-circuit currents. The rated insulation voltage is 690 V for the current circuit and 600 V for the signal circuit, according to IEC and CSA standards.
Compatibility and Accessories
The contactor is compatible with various accessories that extend its functionality. These include auxiliary switch blocks such as the LADN31 (3NO1NC non-delayed) or LADN40 (4NO non-delayed), time blocks such as the LADT2 (delayed pickup 0.10–30.00 s) or LADR0 (delayed release 0.10–3.00 s), and main current connectors such as the LAD9V5 (parallel) or LAD9V6 (reversing screw connection). For motor protection, the devices GV2ME32 or GV2LE32 can be combined. Compatibility with the three-phase busbar system GV2G245 and GV2G445 enables flexible mounting in enclosures.
Mounting and Installation
The contactor is designed for mounting in enclosures and can be fixed to standard rails (DIN rail). Dimensions are 45 mm (width) × 85 mm (height) × 101 mm (depth). The spring clamps and Everlink technology allow for quick and secure connection of cables. Installation requires no additional tools, as the terminals feature screw connections or spring clamps. The safety cover protects against unintended access to moving parts.
Advantages in Operation
The contactor offers high reliability through mechanically coupled contacts and a long service life. The integrated coil protection diode reduces stress on control electronics. The high electrical service life and robust construction result in low maintenance costs. Certifications according to international standards enable use in global projects. The combinability with various accessories extends functionality and adaptability to specific requirements.