| Complementary |
| Motor power kW | 5.5 kW at 220/230 V AC 50/60 Hz (AC-3); 11 kW at 380/400 V AC 50/60 Hz (AC-3); 11 kW at 415/440 V AC 50/60 Hz (AC-3); 15 kW at 500 V AC 50/60 Hz (AC-3); 15 kW at 660/690 V AC 50/60 Hz (AC-3); 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e); 11 kW at 380/400 V AC 50/60 Hz (AC-3e); 11 kW at 415/440 V AC 50/60 Hz (AC-3e); 15 kW at 500 V AC 50/60 Hz (AC-3e); 15 kW at 660/690 V AC 50/60 Hz (AC-3e); 5.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 40 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 450 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 240 A 40 °C - 10 s for power circuit; 380 A 40 °C - 1 s for power circuit; 50 A 40 °C - 10 min for power circuit; 120 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at |
| Average impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
| Power dissipation per pole | 3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.65 Mcycles 25 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing; 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms) |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 92 mm |
| Net weight | 0.37 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 25 A (at |
| [Uc] control circuit voltage | 480 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.600 cm |
| Package 1 Width | 9.600 cm |
| Package 1 Length | 11.900 cm |
| Package 1 Weight | 416.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.675 kg |
The LC1D25T7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for motor control and operation of resistive loads. It is designed for use in industrial plants where reliable and safe switching functions are required under high loads. The device has a rated operational current of 25 A at AC-3 and a rated operational power of 11 kW at 400 V AC-3. The control circuit voltage is 480 V AC at 50/60 Hz, making it suitable for applications in medium to high voltage ranges. The coil is designed without an integrated control module, enabling flexible integration into existing control systems.
Applications
The contactor is approved for categories AC-1, AC-3, AC-3e, and AC-4, allowing it to be used for both motor operation and resistive loads. Category AC-3e permits use under special requirements for motor control, such as frequent starts and stops. Motor powers range from 5.5 kW to 15 kW depending on voltage, with values for 380/400 V AC-3 and AC-3e each being 11 kW. Approval for AC-4 also makes the device suitable for applications with high inrush currents, such as cranes or presses.
Functions and Equipment in Detail
The contactor features 3 normally closed contacts in the main current circuit and additionally includes an auxiliary contact block with 1 normally closed and 1 normally open contact. These auxiliary contacts enable integration into control and monitoring systems, for example for status indication or feedback to a control system. The contacts are mechanically coupled and feature mirror contacts, increasing reliability in safety-critical applications. Current connections are made via Everlink and spring terminals, ensuring a secure and long-lasting connection. The operating time is between 12 and 22 seconds, sufficient for most industrial applications.
Technology Explained Simply
The rated insulation voltage is 690 V for the current circuit and complies with standards IEC 60947-4-1, CSA, and UL. The overvoltage category III and pollution degree 3 indicate that the device is designed for industrial environments with increased stress. The rated impulse voltage withstand is 6 kV, ensuring robustness against transient voltage surges. The rated breaking capacity is 450 A at 440 V, highlighting the contactor’s ability to safely interrupt short-circuit currents. The mechanical life is 15 million switching cycles, and the electrical life is 1.65 million cycles at 25 A AC-3.
Compatibility and Accessories
The contactor is compatible with various accessories that extend its functionality. These include motor protection relays such as LRD22, time blocks such as LADT2 or LADT4, auxiliary switch blocks such as LADN31 or LADN40, and mechanical interlocks such as LAD9V2. These components can be used to expand control functions, introduce time delays, or provide mechanical interlocking of switching operations. The use of Everlink connectors enables quick and secure installation.
Mounting and Installation
Mounting is done in standard control panels using screw fastening. Dimensions are 45 mm (width) × 85 mm (height) × 92 mm (depth), allowing for compact placement in enclosures. Spring terminals and Everlink connections ensure a secure current connection without additional tools. Installation is typically performed by skilled professionals in electrical and plant engineering, adhering to standards and safety regulations.
Operational Advantages
The contactor offers high operational safety through mechanically coupled contacts and mirror contacts, increasing reliability in safety-critical applications. The long service life and high breaking capacity ensure low-maintenance operation. Certifications according to DNV, CSA, RINA, GOST, LROS, CCC, GL, BV, and UL confirm suitability for international applications, particularly in shipping, energy, and process industries. The use of Everlink and spring terminals reduces installation time and improves contact quality.
Safety Level
The contactor meets safety application requirements according to EN/ISO 13849-1 with a safety level B10d of 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load. This makes it suitable for applications requiring high reliability and safety, such as automation technology or emergency shutdowns.
Certifications
The device is certified according to DNV, CSA, RINA, GOST, LROS (Lloyds Register of Shipping), CCC, GL, BV, and UL. These certifications confirm suitability for use in various industries, especially in shipping, energy supply, and process industry. Approval according to IEC 60947-4-1 and UL/CSA standards ensures compliance with international standards.
Compatibility with Accessories
Compatible accessories include motor protection relays (e.g. LRD22), time blocks (e.g. LADT2, LADT4), auxiliary switch blocks (e.g. LADN31, LADN40), mechanical interlocks (e.g. LAD9V2), and reversing contactor kits (LAD-9R1V). These components extend the functionality of the contactor and allow flexible adaptation to specific requirements.
Certifications
- DNV, CSA, RINA, GOST, LROS (Lloyds Register of Shipping), CCC, GL, BV, UL
- IEC 60947-4-1, UL/CSA Standards
Compatibility
- Accessories: LRD22, LADT2, LADN31, LAD8N02, LAD8N20, LAD-R4, GV2ME22, LADN40, LAD9V6, LADN11, LADT4, LAD9ET1S, LADR2, LADR0, LAD8N11, LADN20, GV2LE22, LAD9V2, KIT LAD-9R1V
Operating Conditions
- Operating temperature: -40 °C to +70 °C (for drop-out voltage)
- Operating temperature: -40 °C to +60 °C (for operation)
- Control circuit voltage limits: 0.3–0.6 Uc (drop-out voltage), 0.8–1.1 Uc (operation)