Schneider Electric LC1D258P7, EAN: 3389110250275

Schneider Electric LC1D258P7 Contactor 2S+2Ö 40A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D258P7 Contactor 2S+2Ö 40A

Lieske Part No. 512107
Mfg Part No LC1D258P7
EAN-Code 3389110250275
Manufacturer Schneider Electric
Here only 139,07 EUR
165,49 EUR incl. VAT

Further information for Schneider Electric LC1D258P7 Contactor 2S+2Ö 40A

Complementary
Compatibility codeLC1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 40 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current240 A 40 °C - 10 s for power circuit; 380 A 40 °C - 1 s for power circuit; 50 A 40 °C - 10 min for power circuit; 120 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at
Average impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Power dissipation per pole3.2 W AC-1
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.4 Mcycles 40 A AC-1 at Ue
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…60 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12...22 ms closing; 4...19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms)
Height91 mm
Width45 mm
Depth99 mm
Net weight0.425 kg
Logistical informations
Country of originID
Main
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current40 A (at
[Uc] control circuit voltage230 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.5 cm
Package 1 Width9.5 cm
Package 1 Length11.7 cm
Package 1 Weight468 g
Unit Type of Package 2S02
Number of Units in Package 216
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight8.049 kg
Unit Type of Package 3P06
Number of Units in Package 3192
Package 3 Height75 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight105.088 kg
TeSys LC1D power contactor. 4-pole, 2 NO + 2 NC. Additional auxiliary contacts - 1 NO + 1 NC, coil 230 V AC. Dimensions (WxHxD) 45x105x99 mm, weight 0.425 kg. Category AC-1. Without integrated circuit module. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to RINA, CCC, LROS (Lloyds register of shipping), GOST, UL, BV, GL, DNV, CSA. Product standards in accordance with.