Schneider Electric LC1D256B7, EAN: 3389110804454

Schneider Electric LC1D256B7 contactor 3p 24V

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D256B7 contactor 3p 24V

Lieske Part No. 495595
Mfg Part No LC1D256B7
EAN-Code 3389110804454
Manufacturer Schneider Electric
Here only 115,56 EUR
137,52 EUR incl. VAT

Further information for Schneider Electric LC1D256B7 contactor 3p 24V

Complementary
Motor power kW5.5 kW at 220/230 V AC 50/60 Hz (AC-3); 11 kW at 380/400 V AC 50/60 Hz (AC-3); 11 kW at 415/440 V AC 50/60 Hz (AC-3); 15 kW at 500 V AC 50/60 Hz (AC-3); 15 kW at 660/690 V AC 50/60 Hz (AC-3); 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e); 11 kW at 380/400 V AC 50/60 Hz (AC-3e); 11 kW at 415/440 V AC 50/60 Hz (AC-3e); 15 kW at 500 V AC 50/60 Hz (AC-3e); 15 kW at 660/690 V AC 50/60 Hz (AC-3e); 5.5 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 40 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current240 A 40 °C - 10 s for power circuit; 380 A 40 °C - 1 s for power circuit; 50 A 40 °C - 10 min for power circuit; 120 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at
Average impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Power dissipation per pole3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.65 Mcycles 25 A AC-3 at Ue
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12...22 ms closing; 4...19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Connections - terminalsControl circuit: lugs-ring terminals - external diameter: 8 mm; Power circuit: lugs-ring terminals - external diameter: 10 mm
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (8 Gn for 11 ms)
Height85 mm
Width45 mm
Depth92 mm
Net weight0.37 kg
Logistical informations
Country of originFR
Main
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current25 A (at
[Uc] control circuit voltage24 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.000 cm
Package 1 Width5.600 cm
Package 1 Length9.600 cm
Package 1 Weight429.000 g
The LC1D256B7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for motor control and operation of resistive loads. It features a coil with a control circuit voltage of 24 V AC at 50/60 Hz and is designed for use in industrial plants where reliable and safe switching function is required. The device is rated for usage categories AC-3, AC-3e, AC-1, and AC-4, with category AC-3 representing the typical application for controlling three-phase motors. At an operating voltage of 400 V AC and a rated current of 25 A, the contactor achieves a motor power of 11 kW. The maximum motor power is 15 kW at 660/690 V AC, with values varying depending on voltage and usage category. The rated insulation voltage is 690 V for the circuit and complies with standards IEC 60947-4-1, with certifications also available according to UL, CSA, CCC, GOST, BV, LROS, GL, DNV, and RINA. Overvoltage category III and pollution degree 3 indicate suitability for industrial environments with increased stress.

Applications

The contactor is primarily intended for controlling three-phase motors in industrial plants, particularly in applications with medium to high load, such as in manufacturing, packaging industry, or conveying technology. The usage category AC-3e enables use in special requirements, such as with pumps or fans with high inrush currents. Category AC-4 is suitable for applications with frequent starting and stopping, such as cranes or lifting equipment. The integrated safety cover increases protection against contact and meets requirements for safety-critical installations. The mechanically coupled contacts and mirror contacts make the device suitable for safety applications where secure disconnection of circuits is required.

Functions and Equipment in Detail

The contactor features 3 normally closed contacts in the main circuit and additionally includes an auxiliary contact block with 1 normally closed and 1 normally open contact. These auxiliary contacts enable integration into control and monitoring systems, e.g., for feedback of the switching state to a control system. The contact configuration 3 S (3 normally closed) is designed for standard applications in motor control. The spring terminals and Everlink technology ensure a secure and long-lasting electrical connection that remains stable even under vibration and mechanical stress. The coil is designed without an integrated control module, enabling flexible integration into existing control systems. The operating time is between 12 and 22 milliseconds, ensuring fast switching performance.

Technology Explained Simply

The control circuit voltage of 24 V AC is a common voltage in industrial control systems and allows easy integration into existing systems. The rated short-time withstand current is 240 A at 40 °C for 10 seconds in the circuit, demonstrating the contactor’s ability to withstand short-term overloads. The rated breaking capacity is 450 A at 440 V, meeting the requirements of IEC 60947 and ensuring safe interruption in fault conditions. The rated making capacity is 450 A at 440 V for the circuit, indicating the ability to safely switch under load. The power loss per pole is 1.25 W at AC-3 and AC-3e, indicating efficient heat dissipation. The heat dissipation is between 2 and 3 W at 50/60 Hz, describing the thermal load on the device.

Compatibility and Accessories

The contactor is compatible with various accessories that extend its functionality. These include time modules such as LA4-DT0U (0.1–2 s) or LA4-DT2U (1.5–30 s), suitable for delayed switching operations. Auxiliary switch blocks such as LADN136 (1S3Ö) or LADN206 (2S) allow expansion of the contact configuration. For special applications, time blocks such as LADT46 (1S1Ö, delayed engagement) or interface module LA4-DWB are available. Compatibility with motor protection circuit breakers such as GV2G245 or GV2LE22 enables integration into comprehensive protection concepts. Combination with reversing contactors is possible via kit LAD9R1, enabling complex drive control systems.

Mounting and Installation

Mounting is done via standard plug-in connection, enabling quick and easy installation. Dimensions are 45 mm (width) × 85 mm (height) × 92 mm (depth), allowing placement in standard control panels. The spring terminals require no additional tools for connection and ensure secure current conduction. Installation is in free air, with the conventional thermal current (Ith) at 60 °C being 40 A for the circuit. Operating temperature ranges are between -40 °C and +70 °C, with operating voltage limits between 0.8 and 1.1 Uc (at -40…60 °C). The mechanical life is 15 million switching cycles, and the electrical life is 1.65 million cycles at 25 A AC-3 and rated voltage. The safety cover is already integrated and meets the requirements for protection class IP20.

Advantages in Operation

The contactor offers high reliability due to its robust construction and long-lasting contacts. The integrated safety cover and mechanically coupled contacts increase safety in critical applications. The use of Everlink technology and spring terminals ensures a stable electrical connection that remains secure even under mechanical stress. Compatibility with various accessories enables flexible adaptation to different requirements. Certifications according to international standards such as IEC, UL, CSA, CCC, and others guarantee suitability for use in various markets. Low power loss and efficient heat dissipation reduce thermal load on the device and its environment. The operating time of 12–22 ms ensures fast response in control processes.