| Complementary |
| Motor power kW | 4 kW at 220/230 V AC 50/60 Hz (AC-3); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3); 9 kW at 415/440 V AC 50/60 Hz (AC-3); 10 kW at 500 V AC 50/60 Hz (AC-3); 10 kW at 660/690 V AC 50/60 Hz (AC-3); 4 kW at 220/230 V AC 50/60 Hz (AC-3e); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 9 kW at 415/440 V AC 50/60 Hz (AC-3e); 10 kW at 500 V AC 50/60 Hz (AC-3e); 10 kW at 660/690 V AC 50/60 Hz (AC-3e); 4 kW at 400 V AC 50/60 Hz (AC-4) |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit; 32 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 300 kA at 440 V for power circuit conforming to IEC 60947 |
| Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1; 35 A at |
| Average impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Power dissipation per pole | 0.8 W AC-3; 2.5 W AC-1; 0.8 W AC-3e |
| [Ui] rated insulation voltage | Control circuit: 600 V CSA certified; Control circuit: 600 V UL certified; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Control circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (60 °C):operational AC 50 Hz; 0.85...1.1 Uc (60 °C):operational AC 60 Hz |
| Inrush power in VA | 70 VA cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7 VA 50/60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz for control circuit |
| Operating time | 4...19 ms opening; 12...22 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque | Control circuit: 1.7 N.m - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - with screwdriver Philips No 2; Power circuit: 1.7 N.m - with screwdriver flat Ø 6 mm; Power circuit: 1.7 N.m - with screwdriver Philips No 2; Control circuit: 1.7 N.m - with screwdriver pozidriv No 2; Power circuit: 1.7 N.m - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; UL 60947-4-1; EN/IEC 60947-5-1; CSA C22.2 No 14; IEC 60335-1 |
| Product certifications | GOST; GL; DNV; LROS (Lloyds register of shipping); RINA; BV; CCC; UL; CSA; UKCA |
| IP degree of protection | IP2X conforming to IEC 60529; IP2X conforming to VDE 0106 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -5…60 °C; -40…70 °C at Uc |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Shocks contactor opened (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms) ; Vibrations contactor opened (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 3.3 kg |
| Quantity per set | Set of 10 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 32 A (at |
| [Uc] control circuit voltage | 240 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 15.0 cm |
| Package 1 Width | 30.0 cm |
| Package 1 Length | 40.0 cm |
| Package 1 Weight | 320.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 8.135 kg |
The LC1D18U7TQ contactor from the TeSys Deca series by Schneider Electric is a 3-pole contactor for motor control and operation with resistive loads. It is designed for use categories AC-3, AC-3e, and AC-1, and is particularly suitable for use in industrial plants where reliable and safe switching function is required. The device features a coil with a control circuit voltage of 240 V AC at 50/60 Hz and is equipped with an integrated auxiliary contact block comprising 1 NO and 1 NC contact. The rated operational power is 7.5 kW at AC-3 and 400 V AC, with a rated operational current Ie of 18 A.
Applications
This contactor is designed for use in industrial plants, particularly in motor control applications. It is suitable for drives with a power up to 10 kW at various voltage levels, with the exact motor power depending on voltage and usage category. The AC-3e category allows use in specific drive requirements, such as those encountered with pumps or fans. Certification to EN/IEC 60947-4-1 and UL 508 makes it suitable for use in safety-critical applications, particularly due to mechanically interlocked contacts and mirror contacts ensuring a safe switching function.
Functions and Equipment in Detail
The contactor features a 3-pole main contact arrangement with 3 NO contacts responsible for the main current connection. The auxiliary contacts (1 NO + 1 NC) enable integration into control circuits, for example for feedback or signaling. The contacts are equipped with Everlink and spring terminals, ensuring a secure and long-lasting current connection. The mechanical life is 15 million switching cycles, guaranteeing high operational reliability and longevity. The maximum operating rate is 3600 switching operations per hour at an ambient temperature of 60 °C.
Technology Explained Simply
The contactor coil is supplied with 240 V AC and has an inrush power of 70 VA at 20 °C. The holding power consumption is 7 VA at 50/60 Hz. The operating time is 4 to 19 ms for opening and 12 to 22 ms for closing. The rated insulation voltage is 690 V for both current and control circuits according to IEC 60947-4-1. The overvoltage category III and rated impulse voltage withstand of 6 kV ensure high electrical safety. The rated breaking capacity is 300 kA at 440 V, indicating high short-circuit resistance. The associated fuse for the control circuit is 10 A gG.
Compatibility and Accessories
The contactor is compatible with various accessories that extend its functionality. These include auxiliary contact blocks such as LADN20 (2 NO) or LADN02 (2 NC), time blocks such as LADT2 (delayed pickup, 0.10–30.00 s) or LADR2 (delayed release, 1–30.00 s), and main current connectors such as LAD9V6 for screw connection. Additionally, varistors (e.g. LAD-4VU) and RC elements (e.g. LAD4RCU) are available to protect the coil. Mounting is on a rail or plate, with dimensions of 45 mm (width) × 77 mm (height) × 86 mm (depth).
Mounting and Installation
Mounting is on a standard rail (DIN rail) or directly on a plate. The connection terminals are designed for cable cross-sections from 1.5 to 6 mm², with a tightening torque of 1.7 Nm for screw connections. The use of Everlink and spring terminals ensures a secure and durable connection. Installation is in a closed enclosure, with ambient temperature up to 60 °C permitted.
Operational Advantages
The contactor offers high operational reliability through mechanically interlocked contacts and mirror contacts, ensuring a safe switching function. The long mechanical life of 15 million cycles and high short-circuit resistance of 300 kA at 440 V ensure reliable performance even under harsh operating conditions. The integrated auxiliary contacts enable easy integration into control and monitoring systems. Certifications to GOST, GL, DNV, LROS, RINA, BV, CCC, UL, and CSA, as well as compliance with EN/IEC 60947-4-1 and UL 508, make it suitable for use in various industries and regions. The maximum operating rate of 3600 switching operations per hour at 60 °C demonstrates the high load capacity of the device.